192 lines
6.7 KiB
Groff
192 lines
6.7 KiB
Groff
.TH POWERCOM 8 "Fri Jan 25 2008" "" "Network UPS Tools (NUT)"
|
|
.SH NAME
|
|
powercom \- UPS driver for Powercom/Trust/Advice UPS equipment
|
|
|
|
.SH NOTE
|
|
This man page only documents the hardware\(hyspecific features of the
|
|
powercom driver. For information about the core driver, see
|
|
\fBnutupsdrv\fR(8).
|
|
|
|
.SH SUPPORTED HARDWARE
|
|
This driver supports many similar kinds of UPS hardware. The most common
|
|
ones are the Trust 425/625, Powercom, and Advice Partner/King PR750.
|
|
Others using the same protocol may also work.
|
|
|
|
.SH EXTRA ARGUMENTS
|
|
This driver supports the following optional settings in the
|
|
\fBups.conf\fR(5):
|
|
|
|
.IP "linevoltage=\fIvalue\fR"
|
|
An integer specifying the mains voltage. It can't be auto detected.
|
|
Acceptable values are in the range of 110\(hy120 or 220\(hy240. The default
|
|
is \fI230\fR.
|
|
|
|
.IP "manufacturer=\fIname\fR"
|
|
Specify the manufacturer name, which also can't be auto detected. This is
|
|
a user defined string so any name is acceptable. The default is
|
|
\fIPowerCom\fR.
|
|
|
|
.IP "modelname=\fIname\fR"
|
|
Specify the model name, which also can't be auto detected. This is a
|
|
user defined string so any name is acceptable. The default is
|
|
\fIUnknown\fR.
|
|
|
|
.IP "serialnumber=\fIvalue\fR"
|
|
Like modelname above, but for the serial number. The default is
|
|
\fIUnknown\fR.
|
|
|
|
.IP "type=\fIname\fR"
|
|
The exact type of the communication protocol within the powercom family,
|
|
that will be used to communicate with the UPS. The type is named after
|
|
the first modelname that was coded with that protocol. The acceptable
|
|
names are KP625AP, Trust, Egys, KIN, BNT, IMP and BNT-other. The default is
|
|
\fITrust\fR.
|
|
\fIBNT-other\fR - it's a special type for BNT 100-120V models
|
|
for this type you can (I think must!) specify voltage, batteryPercentage,
|
|
loadPercentage and validationSequence.
|
|
|
|
.IP "numOfBytesFromUPS=\fIvalue\fR"
|
|
The number of bytes in a UPS frame. The default is type dependant and
|
|
is given below.
|
|
|
|
.IP "methodOfFlowControl=\fIname\fR"
|
|
The method of serial communication flow control that is engaged by the
|
|
UPS. The default is type dependant and is given below. Acceptable names
|
|
are dtr0rts1, dtr1 or no_flow_control.
|
|
|
|
.IP "shutdownArguments=\fI{{minutes,seconds},whether_minutes_should_be_used}\fR"
|
|
The minutes and seconds that the UPS should wait between receiving the
|
|
shutdown command and actually shutting off. The other argument should
|
|
be set to the character \fIn\fR only when the minutes value should be
|
|
skipped and not sent to the UPS. The default is type dependant and is
|
|
given below. The braces and commas are mandatory. Note that there should
|
|
be no white space characters.
|
|
|
|
.IP "voltage=\fI{coefficient1,coefficient2,coefficient3,coefficient4}\fR"
|
|
Only for KP625AP, Trust, Egys, BNT-other
|
|
A quad that is used convert the raw data to human readable voltage
|
|
reading. The default is type dependant and is given below. Do note that
|
|
the braces and commas are mandatory, as well as the lack of white space
|
|
characters.
|
|
|
|
.IP "frequency=\fI{coefficient1,coefficient2}\fR"
|
|
Only for KP625AP, Trust, Egys
|
|
A pair to convert the raw data to human readable frequency reading. The
|
|
default is type dependant and is given below. Do note that the braces
|
|
and commas are mandatory as well, as the lack of white space characters.
|
|
|
|
.IP "batteryPercentage=\fI{coefficient1,coefficient2,coefficient3,coefficient4,coefficient5}\fR"
|
|
Only for KP625AP, Trust, Egys, BNT-other
|
|
A 5 tuple to convert the raw data to human readable battery percentage
|
|
reading. The default is type dependant and is given below. Do note that
|
|
the braces and commas are mandatory, as the lack of white space
|
|
characters.
|
|
|
|
.IP "loadPercentage=\fI{coefficient1,coefficient2,coefficient3,coefficient4}\fR"
|
|
Only for KP625AP, Trust, Egys, BNT-other
|
|
A quad to convert the raw data to human readable load percentage
|
|
reading. The default is type dependant and is given below. Do note that
|
|
the braces and commas are mandatory, as the lack of white space
|
|
characters.
|
|
|
|
.IP "validationSequence=\fI{{index1,value1},{index2,value2},{index3,value3}}\fR"
|
|
Only for KP625AP, Trust, Egys, BNT-other
|
|
3 pairs to be used for validating the UPS by comparing bytes of the raw
|
|
data with constant values. The default is type dependant and is given
|
|
below. The braces and commas are mandatory, as the lack of white space
|
|
characters.
|
|
|
|
.SH DEFAULT VALUES FOR THE EXTRA ARGUMENTS
|
|
.IP "linevoltage = \fI230\fR"
|
|
.IP "manufacturer = \fIPowerCom\fR"
|
|
.IP "modelname = \fIUnknown\fR"
|
|
.IP "serialnumber = \fIUnknown\fR"
|
|
.IP "type = \fITrust\fR"
|
|
|
|
.P
|
|
The rest of the default values for the extra arguments are type
|
|
dependant:
|
|
|
|
.IP "Trust"
|
|
.RS
|
|
.IP "numOfBytesFromUPS = 11"
|
|
.IP "methodOfFlowControl = dtr0rts1"
|
|
.IP "validationSequence = {{5,0},{7,0},{8,0}}"
|
|
.IP "shutdownArguments = {{0,10},n}"
|
|
.IP "frequency = {0.00020997,0.00020928}"
|
|
.IP "loadPercentage = {6.1343,\-0.3808,4.3110,0.1811}"
|
|
.IP "batteryPercentage = {5.0000,0.3268,\-825.00,4.5639,\-835.82}"
|
|
.IP "voltage = {1.9216,\-0.0977,0.9545,0.0000}"
|
|
.RE
|
|
|
|
.IP "KP625AP"
|
|
.RS
|
|
.IP "numOfBytesFromUPS = 16"
|
|
.IP "methodOfFlowControl = dtr0rts1"
|
|
.IP "validationSequence = {{5,0x80},{7,0},{8,0}}"
|
|
.IP "shutdownArguments = {{0,10},n}"
|
|
.IP "frequency = {0.00020997,0.00020928}"
|
|
.IP "loadPercentage = {6.1343,\-0.3808,4.3110,0.1811}"
|
|
.IP "batteryPercentage = {5.0000,0.3268,\-825.00,4.5639,\-835.82}"
|
|
.IP "voltage = {1.9216,\-0.0977,0.9545,0.0000}"
|
|
.RE
|
|
|
|
.IP "Egys"
|
|
.RS
|
|
.IP "numOfBytesFromUPS = 16"
|
|
.IP "methodOfFlowControl = no_flow_control"
|
|
.IP "validationSequence = {{5,0x80},{7,0},{8,0}}"
|
|
.IP "shutdownArguments = {{0,10},n}"
|
|
.IP "frequency = {0.00020997,0.00020928}"
|
|
.IP "loadPercentage = {6.1343,\-0.3808,1.3333,0.6667}"
|
|
.IP "batteryPercentage = {5.0000,0.3268,\-825.00,2.2105,\-355.37}"
|
|
.IP "voltage = {1.9216,\-0.0977,0.9545,0.0000}"
|
|
.RE
|
|
|
|
.IP "IMP"
|
|
.RS
|
|
.IP "numOfBytesFromUPS = 16"
|
|
.IP "methodOfFlowControl = no_flow_control"
|
|
.IP "validationSequence = {{5,0xFF},{7,0},{8,0}}"
|
|
.IP "shutdownArguments = {{1,30},y}"
|
|
.RE
|
|
|
|
.IP "KIN"
|
|
.RS
|
|
.IP "numOfBytesFromUPS = 16"
|
|
.IP "methodOfFlowControl = no_flow_control"
|
|
.IP "validationSequence = {{11,0x4b},{8,0},{8,0}}"
|
|
.IP "shutdownArguments = {{1,30},y}"
|
|
.RE
|
|
|
|
.IP "BNT"
|
|
.RS
|
|
.IP "numOfBytesFromUPS = 16"
|
|
.IP "methodOfFlowControl = no_flow_control"
|
|
.IP "validationSequence = {{11,0x42},{8,0},{8,0}}"
|
|
.IP "shutdownArguments = {{1,30},y}"
|
|
.RE
|
|
|
|
.IP "BNT-other"
|
|
.RS
|
|
.IP "numOfBytesFromUPS = 16"
|
|
.IP "methodOfFlowControl = no_flow_control"
|
|
.IP "validationSequence = {{8,0},{8,0},{8,0}}"
|
|
.IP "shutdownArguments = {{1,30},y}"
|
|
.IP "loadPercentage = {1.4474,0.0,0.8594,0.0}"
|
|
.IP "batteryPercentage = {5.0000,0.3268,\-825.00,0.46511,0}"
|
|
.IP "voltage = {1.9216,\-0.0977,0.82857,0.0000}"
|
|
.RE
|
|
|
|
.SH AUTHOR
|
|
Peter Bieringer <pb@bieringer.de>
|
|
Alexey Sidorov <alexsid@altlinux.org>
|
|
|
|
.SH SEE ALSO
|
|
|
|
.SS The core driver:
|
|
\fBnutupsdrv\fR(8)
|
|
|
|
.SS Internet resources:
|
|
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
|