UPSCMD(8)
|
|
=========
|
|
|
|
NAME
|
|
----
|
|
upscmd - UPS administration program for instant commands
|
|
|
|
SYNOPSIS
|
|
--------
|
|
*upscmd* -h
|
|
|
|
*upscmd* -l 'ups'
|
|
|
|
*upscmd* [-u 'username'] [-p 'password'] 'ups' 'command'
|
|
|
|
DESCRIPTION
|
|
-----------
|
|
|
|
*upscmd* allows you to invoke "instant commands" in your UPS hardware.
|
|
Not all hardware supports this, so check the list with -l to see if anything
|
|
will work on your equipment.
|
|
|
|
On hardware that supports it, you can use this program to start and stop
|
|
battery tests, invoke a front panel test (beep!), turn the load on or off,
|
|
and more.
|
|
|
|
OPTIONS
|
|
-------
|
|
|
|
*-h*::
|
|
Display the help message.
|
|
|
|
*-l* 'ups'::
|
|
Show the list of supported instant commands on that UPS. Some hardware
|
|
may not support any of them.
|
|
|
|
*-u* 'username'::
|
|
Set the username for the connection to the server. This is optional, and
|
|
you will be prompted for this when invoking a command if -u is not used.
|
|
|
|
*-p* 'password'::
|
|
Set the password to authenticate to the server. This is also optional
|
|
like -u, and you will be prompted for it if necessary.
|
|
|
|
'ups'::
|
|
Connect to this UPS. The format is `upsname[@hostname[:port]]`. The default
|
|
hostname is "localhost".
|
|
|
|
UNATTENDED MODE
|
|
---------------
|
|
|
|
If you run this program inside a shell script or similar to invoke
|
|
a command, you will need to specify all of the information on the command
|
|
line. This means using -u and -p. Otherwise it will put up a prompt and
|
|
your program will hang.
|
|
|
|
This is not necessary when displaying the list, as the username and
|
|
password are not required for read-only mode.
|
|
|
|
Moreover, if you run this program inside a shell script or similar, you
|
|
should only consider using output from stdout, not stderr.
|
|
|
|
DANGEROUS COMMANDS
|
|
------------------
|
|
|
|
Some drivers like linkman:apcsmart[8] have built-in paranoia for the
|
|
dangerous commands like `load.off`. To make them actually turn off the
|
|
load, you will have to send the command twice within a short window.
|
|
That is, you will have to send it once, then send it again after 3
|
|
seconds elapse but before 15 seconds pass.
|
|
|
|
This paranoia is entirely defined within the driver. upsd and upscmd have
|
|
no control over the timing.
|
|
|
|
DIAGNOSTICS
|
|
-----------
|
|
|
|
upscmd won't work unless you provide a valid username and password. If
|
|
you get "access denied" errors, make sure that your linkman:upsd.users[5] has
|
|
an entry for you, and that the username you are using has permissions to
|
|
SET variables.
|
|
|
|
BUGS
|
|
----
|
|
|
|
There is currently no way to tell the user when the driver requires
|
|
confirmation to invoke a command such as `load.off`. Similarly, there is
|
|
not yet a way to tell the user if a command succeeds or fails.
|
|
|
|
This is on the list of things to fix in the future, so don't despair.
|
|
It involves magic cookies.
|
|
|
|
SEE ALSO
|
|
--------
|
|
linkman:upsd[8], linkman:upsrw[8]
|
|
|
|
INTERNET RESOURCES
|
|
------------------
|
|
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
|