MACOSX-UPS(8)
|
|
=============
|
|
|
|
NAME
|
|
----
|
|
macosx-ups - monitor for Mac OS X built-in UPS and battery driver
|
|
|
|
NOTE
|
|
----
|
|
This man page only documents the hardware-specific features of the
|
|
*macosx-ups* driver. For information about the core driver, see
|
|
linkman:nutupsdrv[8].
|
|
|
|
SUPPORTED HARDWARE
|
|
------------------
|
|
*macosx-ups* supports any USB HID Power Device Class (PDC) UPS which is
|
|
matched by the Mac OS X built-in drivers. It also can monitor a laptop
|
|
internal battery as though it were an UPS.
|
|
|
|
If the UPS is visible in the Energy Saver preferences pane of System
|
|
Preferences, this driver should be able to monitor it.
|
|
|
|
|
|
EXTRA ARGUMENTS
|
|
----------------
|
|
*port*='regex'::
|
|
The *port* parameter in the configuration file can be a case-insensitive
|
|
extended regular expression (see *regex*(3) for details) to match against
|
|
specific UPS and battery names.
|
|
+
|
|
The traditional NUT auto-detection value of "auto" will be changed to "/UPS".
|
|
To test this driver against the internal battery of a laptop, a value such as
|
|
"battery" can be used.
|
|
|
|
*model*='regex'::
|
|
Likewise, if you have more than one UPS, it may be necessary to specify a
|
|
*model* name to match against. This parameter is also a case-insensitive
|
|
extended regular expression.
|
|
|
|
//////////////////////////////////////////
|
|
This driver also supports the following optional settings:
|
|
|
|
*option1*='num'::
|
|
Set the value of ... to 'num'. Contrast with *option2*.
|
|
|
|
*option2*='string'::
|
|
Some other option.
|
|
//////////////////////////////////////////
|
|
|
|
//////////////////////////////////////////
|
|
Optional: list supported instant commands here:
|
|
|
|
INSTANT COMMANDS
|
|
----------------
|
|
|
|
*instcmd1*::
|
|
Command 1.
|
|
//////////////////////////////////////////
|
|
|
|
DIAGNOSTICS
|
|
-----------
|
|
|
|
If the driver cannot find an UPS, first open System Preferences and see if
|
|
there is an "UPS" tab on the Energy Saver panel. If so, re-run the driver with
|
|
the *-D* flag to list the names of the power sources found.
|
|
|
|
KNOWN ISSUES AND BUGS
|
|
---------------------
|
|
|
|
This driver is a monitoring-only driver, and cannot shut down an UPS on its
|
|
own. However, this should not be a problem in practice: it is monitoring the
|
|
built-in Mac OS X UPS driver, which has configuration options for several
|
|
shutdown scenarios. Consult the Energy Saver control panel or *pmset*(8) for
|
|
more information.
|
|
|
|
The default distribution of *apcupsd* installs a kernel extension which
|
|
prevents Mac OS X from attaching to the UPS. In order to use this driver after
|
|
installing apcupsd, you must first run the `apcupsd-uninstall` script and
|
|
reboot.
|
|
|
|
Note that other UPS monitoring solutions may show more detail than what is
|
|
provided by the built-in Mac OS X driver. In particular, voltages other than
|
|
the battery voltage, as well as current and frequency, are typically not
|
|
shown. It may be possible to monitor these values with *apcupsd* (for APC
|
|
hardware only) or linkman:usbhid-ups[8].
|
|
|
|
AUTHORS
|
|
-------
|
|
Charles Lepple <clepple+nut at gmail.com>
|
|
|
|
SEE ALSO
|
|
--------
|
|
|
|
linkman:usbhid-ups[8], *pmset*(8), *regex*(3)
|
|
|
|
The core driver:
|
|
~~~~~~~~~~~~~~~~
|
|
linkman:nutupsdrv[8]
|
|
|
|
Internet resources:
|
|
~~~~~~~~~~~~~~~~~~~
|
|
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
|
|
|
|
The apcupsd home page: http://www.apcupsd.org/
|