/* powercom-hid.c - subdriver to monitor PowerCOM USB/HID devices with NUT
|
|
*
|
|
* Copyright (C)
|
|
* 2003 - 2009 Arnaud Quette <ArnaudQuette@Eaton.com>
|
|
* 2005 - 2006 Peter Selinger <selinger@users.sourceforge.net>
|
|
* 2008 - 2009 Arjen de Korte <adkorte-guest@alioth.debian.org>
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation; either version 2 of the License, or
|
|
* (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with this program; if not, write to the Free Software
|
|
* Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
|
|
*/
|
|
|
|
#include "main.h" /* for getval() */
|
|
#include "usbhid-ups.h"
|
|
#include "powercom-hid.h"
|
|
#include "usb-common.h"
|
|
|
|
#define POWERCOM_HID_VERSION "PowerCOM HID 0.3"
|
|
/* FIXME: experimental flag to be put in upsdrv_info */
|
|
|
|
/* PowerCOM */
|
|
#define POWERCOM_VENDORID 0x0d9f
|
|
|
|
/* USB IDs device table */
|
|
static usb_device_id_t powercom_usb_device_table[] = {
|
|
/* PowerCOM IMP - IMPERIAL Series */
|
|
{ USB_DEVICE(POWERCOM_VENDORID, 0x00a2), NULL },
|
|
/* PowerCOM SKP - Smart KING Pro (all Smart series) */
|
|
{ USB_DEVICE(POWERCOM_VENDORID, 0x00a3), NULL },
|
|
/* PowerCOM WOW */
|
|
{ USB_DEVICE(POWERCOM_VENDORID, 0x00a4), NULL },
|
|
/* PowerCOM VGD - Vanguard */
|
|
{ USB_DEVICE(POWERCOM_VENDORID, 0x00a5), NULL },
|
|
/* PowerCOM BNT - Black Knight Pro */
|
|
{ USB_DEVICE(POWERCOM_VENDORID, 0x00a6), NULL },
|
|
/* PowerCOM BNT-xxxAP */
|
|
{ USB_DEVICE(POWERCOM_VENDORID, 0x0004), NULL },
|
|
|
|
/* Terminating entry */
|
|
{ -1, -1, NULL }
|
|
};
|
|
|
|
static char powercom_scratch_buf[32];
|
|
|
|
static const char *powercom_startup_fun(double value)
|
|
{
|
|
uint16_t i = value;
|
|
|
|
snprintf(powercom_scratch_buf, sizeof(powercom_scratch_buf), "%d", 60 * (((i & 0x00FF) << 8) + (i >> 8)));
|
|
upsdebugx(3, "%s: value = %.0f, buf = %s", __func__, value, powercom_scratch_buf);
|
|
|
|
return powercom_scratch_buf;
|
|
}
|
|
|
|
static double powercom_startup_nuf(const char *value)
|
|
{
|
|
const char *s = dstate_getinfo("ups.delay.start");
|
|
uint16_t val, command;
|
|
|
|
val = atoi(value ? value : s) / 60;
|
|
command = ((val << 8) + (val >> 8));
|
|
upsdebugx(3, "%s: value = %s, command = %04X", __func__, value, command);
|
|
|
|
return command;
|
|
}
|
|
|
|
static info_lkp_t powercom_startup_info[] = {
|
|
{ 0, NULL, powercom_startup_fun, powercom_startup_nuf }
|
|
};
|
|
|
|
static const char *powercom_shutdown_fun(double value)
|
|
{
|
|
uint16_t i = value;
|
|
|
|
snprintf(powercom_scratch_buf, sizeof(powercom_scratch_buf), "%d", 60 * (i & 0x00FF) + (i >> 8));
|
|
upsdebugx(3, "%s: value = %.0f, buf = %s", __func__, value, powercom_scratch_buf);
|
|
|
|
return powercom_scratch_buf;
|
|
}
|
|
|
|
static double powercom_shutdown_nuf(const char *value)
|
|
{
|
|
const char *s = dstate_getinfo("ups.delay.shutdown");
|
|
uint16_t val, command;
|
|
|
|
val = atoi(value ? value : s);
|
|
command = ((val % 60) << 8) + (val / 60);
|
|
command |= 0x4000; /* AC RESTART NORMAL ENABLE */
|
|
upsdebugx(3, "%s: value = %s, command = %04X", __func__, value, command);
|
|
|
|
return command;
|
|
}
|
|
|
|
static info_lkp_t powercom_shutdown_info[] = {
|
|
{ 0, NULL, powercom_shutdown_fun, powercom_shutdown_nuf }
|
|
};
|
|
|
|
static double powercom_stayoff_nuf(const char *value)
|
|
{
|
|
const char *s = dstate_getinfo("ups.delay.shutdown");
|
|
uint16_t val, command;
|
|
|
|
val = atoi(value ? value : s);
|
|
command = ((val % 60) << 8) + (val / 60);
|
|
command |= 0x8000; /* AC RESTART NORMAL DISABLE */
|
|
upsdebugx(3, "%s: value = %s, command = %04X", __func__, value, command);
|
|
|
|
return command;
|
|
}
|
|
|
|
static info_lkp_t powercom_stayoff_info[] = {
|
|
{ 0, NULL, NULL, powercom_stayoff_nuf }
|
|
};
|
|
|
|
static info_lkp_t powercom_beeper_info[] = {
|
|
{ 1, "enabled", NULL },
|
|
{ 2, "disabled", NULL }, /* muted? */
|
|
{ 0, NULL, NULL }
|
|
};
|
|
|
|
/* --------------------------------------------------------------- */
|
|
/* Vendor-specific usage table */
|
|
/* --------------------------------------------------------------- */
|
|
|
|
/* POWERCOM usage table */
|
|
static usage_lkp_t powercom_usage_lkp[] = {
|
|
{ "POWERCOM1", 0x0084002f },
|
|
{ "POWERCOM2", 0xff860060 },
|
|
{ "POWERCOM3", 0xff860080 },
|
|
{ NULL, 0 }
|
|
};
|
|
|
|
static usage_tables_t powercom_utab[] = {
|
|
powercom_usage_lkp,
|
|
hid_usage_lkp,
|
|
NULL,
|
|
};
|
|
|
|
/* --------------------------------------------------------------- */
|
|
/* HID2NUT lookup table */
|
|
/* --------------------------------------------------------------- */
|
|
|
|
static hid_info_t powercom_hid2nut[] = {
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.ACPresent", NULL, NULL, 0, online_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.BatteryPresent", NULL, NULL, 0, nobattery_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit", NULL, NULL, 0, lowbatt_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Charging", NULL, NULL, 0, charging_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.CommunicationLost", NULL, NULL, 0, commfault_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Discharging", NULL, NULL, 0, discharging_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.NeedReplacement", NULL, NULL, 0, replacebatt_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Overload", NULL, NULL, 0, overload_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.RemainingTimeLimitExpired", NULL, NULL, 0, timelimitexpired_info },
|
|
{ "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.ShutdownImminent", NULL, NULL, 0, shutdownimm_info },
|
|
/* { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.POWERCOM3", NULL, "%.0f", 0, NULL }, */
|
|
/* { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.ShutdownRequested", NULL, "%.0f", 0, NULL }, */
|
|
/* { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.VoltageNotRegulated", NULL, "%.0f", 0, NULL }, */
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.ACPresent", NULL, NULL, 0, online_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.BatteryPresent", NULL, NULL, 0, nobattery_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.BelowRemainingCapacityLimit", NULL, NULL, 0, lowbatt_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.Boost", NULL, NULL, 0, boost_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.Buck", NULL, NULL, 0, trim_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.Charging", NULL, NULL, 0, charging_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.CommunicationLost", NULL, NULL, 0, commfault_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.Discharging", NULL, NULL, 0, discharging_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.NeedReplacement", NULL, NULL, 0, replacebatt_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.Overload", NULL, NULL, 0, overload_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.RemainingTimeLimitExpired", NULL, NULL, 0, timelimitexpired_info },
|
|
{ "BOOL", 0, 0, "UPS.PresentStatus.ShutdownImminent", NULL, NULL, 0, shutdownimm_info },
|
|
/* { "BOOL", 0, 0, "UPS.PresentStatus.POWERCOM3", NULL, "%.0f", 0, NULL }, */
|
|
/* { "BOOL", 0, 0, "UPS.PresentStatus.ShutdownRequested", NULL, "%.0f", 0, NULL }, */
|
|
/* { "BOOL", 0, 0, "UPS.PresentStatus.Tested", NULL, "%.0f", 0, NULL }, */
|
|
/* { "BOOL", 0, 0, "UPS.PresentStatus.VoltageNotRegulated", NULL, "%.0f", 0, NULL }, */
|
|
|
|
/*
|
|
* According to the HID PDC specifications, the below values should report battery.voltage(.nominal)
|
|
* PowerCOM duplicates the output.voltage(.nominal) here, so we ignore them
|
|
* { "battery.voltage", 0, 0, "UPS.PowerSummary.Voltage", NULL, "%.2f", 0, NULL },
|
|
* { "battery.voltage", 0, 0, "UPS.Battery.Voltage", NULL, "%.2f", 0, NULL },
|
|
* { "battery.voltage.nominal", 0, 0, "UPS.PowerSummary.ConfigVoltage", NULL, "%.0f", HU_FLAG_STATIC, NULL },
|
|
* { "battery.voltage.nominal", 0, 0, "UPS.Battery.ConfigVoltage", NULL, "%.0f", HU_FLAG_STATIC, NULL },
|
|
*/
|
|
{ "battery.charge", 0, 0, "UPS.PowerSummary.RemainingCapacity", NULL, "%.0f", 0, NULL },
|
|
{ "battery.charge", 0, 0, "UPS.Battery.RemainingCapacity", NULL, "%.0f", 0, NULL },
|
|
{ "battery.charge.low", 0, 0, "UPS.PowerSummary.RemainingCapacityLimit", NULL, "%.0f", 0, NULL },
|
|
{ "battery.charge.warning", 0, 0, "UPS.PowerSummary.WarningCapacityLimit", NULL, "%.0f", 0, NULL },
|
|
{ "battery.runtime", 0, 0, "UPS.PowerSummary.RunTimeToEmpty", NULL, "%.0f", 0, NULL },
|
|
{ "battery.date", 0, 0, "UPS.Battery.ManufacturerDate", NULL, "%s", HU_FLAG_STATIC, date_conversion },
|
|
{ "battery.type", 0, 0, "UPS.PowerSummary.iDeviceChemistry", NULL, "%s", HU_FLAG_STATIC, stringid_conversion },
|
|
/* { "unmapped.ups.battery.delaybeforestartup", 0, 0, "UPS.Battery.DelayBeforeStartup", NULL, "%.0f", 0, NULL }, */
|
|
/* { "unmapped.ups.battery.initialized", 0, 0, "UPS.Battery.Initialized", NULL, "%.0f", 0, NULL }, */
|
|
|
|
{ "ups.beeper.status", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "%s", 0, powercom_beeper_info },
|
|
{ "ups.beeper.status", 0, 0, "UPS.AudibleAlarmControl", NULL, "%s", 0, powercom_beeper_info },
|
|
{ "ups.load", 0, 0, "UPS.Output.PercentLoad", NULL, "%.0f", 0, NULL },
|
|
{ "ups.date", 0, 0, "UPS.PowerSummary.ManufacturerDate", NULL, "%s", HU_FLAG_STATIC, date_conversion },
|
|
{ "ups.test.result", 0, 0, "UPS.Battery.Test", NULL, "%s", 0, test_read_info },
|
|
/* { "unmapped.ups.powersummary.imanufacturer", 0, 0, "UPS.PowerSummary.iManufacturer", NULL, "%s", HU_FLAG_STATIC, stringid_conversion }, */
|
|
/* { "unmapped.ups.powersummary.iproduct", 0, 0, "UPS.PowerSummary.iProduct", NULL, "%s", HU_FLAG_STATIC, stringid_conversion }, */
|
|
/* { "unmapped.ups.powersummary.iserialnumber", 0, 0, "UPS.PowerSummary.iSerialNumber", NULL, "%s", HU_FLAG_STATIC, stringid_conversion }, */
|
|
/* { "unmapped.ups.iname", 0, 0, "UPS.iName", NULL, "%s", HU_FLAG_STATIC, stringid_conversion }, */
|
|
/* { "unmapped.ups.powersummary.ioeminformation", 0, 0, "UPS.PowerSummary.iOEMInformation", NULL, "%s", HU_FLAG_STATIC, stringid_conversion }, */
|
|
|
|
/* The implementation of the HID path UPS.PowerSummary.DelayBeforeStartup is unconventional:
|
|
* Read:
|
|
* Byte 7, byte 8 (min)
|
|
* Write:
|
|
* Command 4, high byte min, low byte min
|
|
*/
|
|
{ "ups.delay.start", ST_FLAG_RW | ST_FLAG_STRING, 8, "UPS.PowerSummary.DelayBeforeStartup", NULL, "60", HU_FLAG_ABSENT, NULL },
|
|
{ "ups.timer.start", 0, 0, "UPS.PowerSummary.DelayBeforeStartup", NULL, "%.0f", 0, powercom_startup_info },
|
|
|
|
/* The implementation of the HID path UPS.PowerSummary.DelayBeforeShutdown is unconventional:
|
|
* Read:
|
|
* Byte 13, Byte 14 (min, sec)
|
|
* Write:
|
|
* If Byte(sec), bit7=0 and bit6=0 Then
|
|
* If Byte 9, bit0=1 Then command 185, 188, min, sec (OL -> shutdown.return)
|
|
* If Byte 9, bit0=0 Then command 186, 188, min, sec (OB -> shutdown.stayoff)
|
|
* If Byte(sec), bit7=0 and bit6=1
|
|
* Then command 185, 188, min, sec (shutdown.return)
|
|
* If Byte(sec), bit7=1 and bit6=0 Then
|
|
* Then command 186, 188, min, sec (shutdown.stayoff)
|
|
* If Byte(sec), bit7=1 and bit6=1 Then
|
|
* No actions
|
|
*/
|
|
{ "ups.delay.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 8, "UPS.PowerSummary.DelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_FLAG_ABSENT, NULL },
|
|
{ "ups.timer.shutdown", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, "%.0f", HU_FLAG_QUICK_POLL, powercom_shutdown_info },
|
|
|
|
{ "input.voltage", 0, 0, "UPS.Input.Voltage", NULL, "%.1f", 0, NULL },
|
|
{ "input.voltage.nominal", 0, 0, "UPS.Input.ConfigVoltage", NULL, "%.0f", HU_FLAG_STATIC, NULL },
|
|
{ "input.frequency", 0, 0, "UPS.Input.Frequency", NULL, "%.1f", 0, NULL },
|
|
|
|
{ "output.voltage", 0, 0, "UPS.Output.Voltage", NULL, "%.1f", 0, NULL },
|
|
{ "output.voltage.nominal", 0, 0, "UPS.Output.ConfigVoltage", NULL, "%.0f", HU_FLAG_STATIC, NULL },
|
|
{ "output.frequency", 0, 0, "UPS.Output.Frequency", NULL, "%.1f", 0, NULL },
|
|
|
|
/* { "unmapped.ups.powercom1", 0, 0, "UPS.POWERCOM1", NULL, "%.0f", 0, NULL }, broken pipe */
|
|
/* { "unmapped.ups.powercom2", 0, 0, "UPS.POWERCOM2", NULL, "%.0f", 0, NULL }, broken pipe */
|
|
/* { "unmapped.ups.powersummary.rechargeable", 0, 0, "UPS.PowerSummary.Rechargeable", NULL, "%.0f", 0, NULL }, */
|
|
/* { "unmapped.ups.shutdownimminent", 0, 0, "UPS.ShutdownImminent", NULL, "%.0f", 0, NULL }, */
|
|
|
|
/* instcmds */
|
|
{ "beeper.toggle", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "1", HU_TYPE_CMD, NULL },
|
|
{ "test.battery.start.quick", 0, 0, "UPS.Battery.Test", NULL, "1", HU_TYPE_CMD, NULL },
|
|
{ "load.on.delay", 0, 0, "UPS.PowerSummary.DelayBeforeStartup", NULL, NULL, HU_TYPE_CMD, powercom_startup_info },
|
|
{ "shutdown.return", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, NULL, HU_TYPE_CMD, powercom_shutdown_info },
|
|
{ "shutdown.stayoff", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, NULL, HU_TYPE_CMD, powercom_stayoff_info },
|
|
|
|
/* end of structure. */
|
|
{ NULL, 0, 0, NULL, NULL, NULL, 0, NULL }
|
|
};
|
|
|
|
static const char *powercom_format_model(HIDDevice_t *hd) {
|
|
return hd->Product;
|
|
}
|
|
|
|
static const char *powercom_format_mfr(HIDDevice_t *hd) {
|
|
return hd->Vendor ? hd->Vendor : "PowerCOM";
|
|
}
|
|
|
|
static const char *powercom_format_serial(HIDDevice_t *hd) {
|
|
return hd->Serial;
|
|
}
|
|
|
|
/* this function allows the subdriver to "claim" a device: return 1 if
|
|
* the device is supported by this subdriver, else 0. */
|
|
static int powercom_claim(HIDDevice_t *hd)
|
|
{
|
|
int status = is_usb_device_supported(powercom_usb_device_table, hd->VendorID, hd->ProductID);
|
|
|
|
switch (status)
|
|
{
|
|
case POSSIBLY_SUPPORTED:
|
|
if (hd->ProductID == 0x0002) {
|
|
upsdebugx(0,
|
|
"This Powercom device (%04x/%04x) is not supported by usbhid-ups.\n"
|
|
"Please use the 'powercom' driver instead.\n", hd->VendorID, hd->ProductID);
|
|
return 0;
|
|
}
|
|
/* by default, reject, unless the productid option is given */
|
|
if (getval("productid")) {
|
|
return 1;
|
|
}
|
|
possibly_supported("PowerCOM", hd);
|
|
return 0;
|
|
|
|
case SUPPORTED:
|
|
return 1;
|
|
|
|
case NOT_SUPPORTED:
|
|
default:
|
|
return 0;
|
|
}
|
|
}
|
|
|
|
subdriver_t powercom_subdriver = {
|
|
POWERCOM_HID_VERSION,
|
|
powercom_claim,
|
|
powercom_utab,
|
|
powercom_hid2nut,
|
|
powercom_format_model,
|
|
powercom_format_mfr,
|
|
powercom_format_serial,
|
|
};
|