'\" t .\" Title: rhino .\" Author: [see the "AUTHOR" section] .\" Generator: DocBook XSL Stylesheets v1.76.1 .\" Date: 07/26/2013 .\" Manual: NUT Manual .\" Source: Network UPS Tools 2.6.5 .\" Language: English .\" .TH "RHINO" "8" "07/26/2013" "Network UPS Tools 2\&.6\&.5" "NUT Manual" .\" ----------------------------------------------------------------- .\" * Define some portability stuff .\" ----------------------------------------------------------------- .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .\" http://bugs.debian.org/507673 .\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .ie \n(.g .ds Aq \(aq .el .ds Aq ' .\" ----------------------------------------------------------------- .\" * set default formatting .\" ----------------------------------------------------------------- .\" disable hyphenation .nh .\" disable justification (adjust text to left margin only) .ad l .\" ----------------------------------------------------------------- .\" * MAIN CONTENT STARTS HERE * .\" ----------------------------------------------------------------- .SH "NAME" rhino \- Driver for Brazilian Microsol RHINO UPS equipment .SH "NOTE" .sp This man page only documents the hardware\-specific features of the rhino driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&. .SH "SUPPORTED HARDWARE" .sp This driver has been tested with : .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} Rhino 6000 VA .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} Rhino 7500 VA .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} Rhino 10000 VA .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} Rhino 20000 VA .RE .sp All Rhino models are sinusoidal on\-line\&. .SH "EXTRA ARGUMENTS" .sp This driver support the following extra optional settings in \fBups.conf\fR(5): .sp \fBbattext = n\fR \- (default = 0, no extra battery, where n = Ampere*hour ) .SH "COMMANDS" .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} load\&.on \- Turn on the load immediately .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} load\&.off \- Turn off the load immediately .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} bypass\&.start \- Put the UPS in bypass mode .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} bypass\&.stop \- Put the UPS out of bypass mode .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} shutdown\&.stayoff \- Shut down in 3 minutes and do not return .RE .SH "AUTHOR" .sp Silvino B\&. Magalhães .SH "SEE ALSO" .SS "The core driver:" .sp \fBnutupsdrv\fR(8) .SS "Internet resources:" .sp The NUT (Network UPS Tools) home page: http://www\&.networkupstools\&.org/