/* mge-hid.c - data to monitor Eaton / MGE HID (USB and serial) devices * * Copyright (C) 2003 - 2012 * Arnaud Quette * * Sponsored by MGE UPS SYSTEMS * * This program is free software; you can redistribute it and/or modify * it under the terms of the GNU General Public License as published by * the Free Software Foundation; either version 2 of the License, or * (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * * You should have received a copy of the GNU General Public License * along with this program; if not, write to the Free Software * Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA * */ /* TODO list: * - better processing of FW info: * * some models (HP R5000) include firmware.aux (00.01.0021;00.01.00) * * other (9130) need more processing (0128 => 1.28) * ... * - better handling of input.transfer.* (need dstate_addrange) * - outlet management logic (Ie, for outlet.X.load.{on,off}.delay * => use outlet.X.delay.{start,stop} */ #include "main.h" /* for getval() */ #include "usbhid-ups.h" #include "mge-hid.h" #define MGE_HID_VERSION "MGE HID 1.32" /* (prev. MGE Office Protection Systems, prev. MGE UPS SYSTEMS) */ /* Eaton */ #define MGE_VENDORID 0x0463 /* Dell */ #define DELL_VENDORID 0x047c /* Powerware */ #define POWERWARE_VENDORID 0x0592 /* Hewlett Packard */ #define HP_VENDORID 0x03f0 #ifndef SHUT_MODE #include "usb-common.h" /* USB IDs device table */ static usb_device_id_t mge_usb_device_table[] = { /* various models */ { USB_DEVICE(MGE_VENDORID, 0x0001), NULL }, { USB_DEVICE(MGE_VENDORID, 0xffff), NULL }, /* various models */ { USB_DEVICE(DELL_VENDORID, 0xffff), NULL }, /* PW 9140 */ { USB_DEVICE(POWERWARE_VENDORID, 0x0004), NULL }, /* R/T3000 */ { USB_DEVICE(HP_VENDORID, 0x1fe5), NULL }, /* R/T3000 */ { USB_DEVICE(HP_VENDORID, 0x1fe6), NULL }, /* various models */ { USB_DEVICE(HP_VENDORID, 0x1fe7), NULL }, { USB_DEVICE(HP_VENDORID, 0x1fe8), NULL }, /* Terminating entry */ { -1, -1, NULL } }; #endif typedef enum { MGE_DEFAULT_OFFLINE = 0, MGE_PEGASUS = 0x100, MGE_3S = 0x110, /* All offline models have type value < 200! */ MGE_DEFAULT = 0x200, /* for line-interactive and online models */ MGE_EVOLUTION = 0x300, /* MGE Evolution series */ MGE_EVOLUTION_650, MGE_EVOLUTION_850, MGE_EVOLUTION_1150, MGE_EVOLUTION_S_1250, MGE_EVOLUTION_1550, MGE_EVOLUTION_S_1750, MGE_EVOLUTION_2000, MGE_EVOLUTION_S_2500, MGE_EVOLUTION_S_3000, MGE_PULSAR_M = 0x400, /* MGE Pulsar M series */ MGE_PULSAR_M_2200, MGE_PULSAR_M_3000, MGE_PULSAR_M_3000_XL } models_type_t; /* Default to line-interactive or online (ie, not offline). * This is then overriden for offline, through mge_model_names */ static models_type_t mge_type = MGE_DEFAULT; /* Countries definition, for region specific settings and features */ typedef enum { COUNTRY_UNKNOWN = -1, COUNTRY_EUROPE = 0, COUNTRY_US, /* Special European models, which also supports 200 / 208 V */ COUNTRY_EUROPE_208, COUNTRY_WORLDWIDE, COUNTRY_AUSTRALIA, } country_code_t; static int country_code = COUNTRY_UNKNOWN; static char mge_scratch_buf[20]; /* The HID path 'UPS.PowerSummary.Time' reports Unix time (ie the number of * seconds since 1970-01-01 00:00:00. This has to be split between ups.date and * ups.time */ static const char *mge_date_conversion_fun(double value) { time_t sec = value; if (strftime(mge_scratch_buf, sizeof(mge_scratch_buf), "%Y/%m/%d", localtime(&sec)) == 10) { return mge_scratch_buf; } upsdebugx(3, "%s: can't compute date %g", __func__, value); return NULL; } static const char *mge_time_conversion_fun(double value) { time_t sec = value; if (strftime(mge_scratch_buf, sizeof(mge_scratch_buf), "%H:%M:%S", localtime(&sec)) == 8) { return mge_scratch_buf; } upsdebugx(3, "%s: can't compute time %g", __func__, value); return NULL; } #ifdef HAVE_STRPTIME /* Conversion back retrieve ups.time to build the full unix time */ static double mge_date_conversion_nuf(const char *value) { struct tm mge_tm; /* build a full value (date) + time string */ snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s %s", value, dstate_getinfo("ups.time")); if (strptime(mge_scratch_buf, "%Y/%m/%d %H:%M:%S", &mge_tm) != NULL) { return mktime(&mge_tm); } upsdebugx(3, "%s: can't compute date %s", __func__, value); return 0; } /* Conversion back retrieve ups.date to build the full unix time */ static double mge_time_conversion_nuf(const char *value) { struct tm mge_tm; /* build a full date + value (time) string */ snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%s %s", dstate_getinfo("ups.date"), value); if (strptime(mge_scratch_buf, "%Y/%m/%d %H:%M:%S", &mge_tm) != NULL) { return mktime(&mge_tm); } upsdebugx(3, "%s: can't compute time %s", __func__, value); return 0; } static info_lkp_t mge_date_conversion[] = { { 0, NULL, mge_date_conversion_fun, mge_date_conversion_nuf } }; static info_lkp_t mge_time_conversion[] = { { 0, NULL, mge_time_conversion_fun, mge_time_conversion_nuf } }; #else static info_lkp_t mge_date_conversion[] = { { 0, NULL, mge_date_conversion_fun, NULL } }; static info_lkp_t mge_time_conversion[] = { { 0, NULL, mge_time_conversion_fun, NULL } }; #endif /* HAVE_STRPTIME */ /* The HID path 'UPS.PowerSummary.ConfigVoltage' only reports 'battery.voltage.nominal' for specific UPS series. Ignore the value for other series (default behavior). */ static const char *mge_battery_voltage_nominal_fun(double value) { switch (mge_type & 0xFF00) /* Ignore model byte */ { case MGE_EVOLUTION: if (mge_type == MGE_EVOLUTION_650) { value = 12.0; } break; case MGE_PULSAR_M: break; default: return NULL; } snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.0f", value); return mge_scratch_buf; } static info_lkp_t mge_battery_voltage_nominal[] = { { 0, NULL, mge_battery_voltage_nominal_fun } }; /* The HID path 'UPS.PowerSummary.Voltage' only reports 'battery.voltage' for specific UPS series. Ignore the value for other series (default behavior). */ static const char *mge_battery_voltage_fun(double value) { switch (mge_type & 0xFF00) /* Ignore model byte */ { case MGE_EVOLUTION: case MGE_PULSAR_M: break; default: return NULL; } snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.1f", value); return mge_scratch_buf; } static info_lkp_t mge_battery_voltage[] = { { 0, NULL, mge_battery_voltage_fun } }; static const char *mge_powerfactor_conversion_fun(double value) { snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.2f", value / 100); return mge_scratch_buf; } static info_lkp_t mge_powerfactor_conversion[] = { { 0, NULL, mge_powerfactor_conversion_fun } }; static const char *mge_battery_capacity_fun(double value) { snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.2f", value / 3600); return mge_scratch_buf; } static info_lkp_t mge_battery_capacity[] = { { 0, NULL, mge_battery_capacity_fun } }; info_lkp_t eaton_enable_disable_info[] = { { 0, "disabled", NULL }, { 1, "enabled", NULL }, { 0, NULL, NULL } }; static info_lkp_t mge_upstype_conversion[] = { { 1, "offline / line interactive", NULL }, { 2, "online", NULL }, { 3, "online - unitary/parallel", NULL }, { 4, "online - parallel with hot standy", NULL }, { 5, "online - hot standby redundancy", NULL }, { 0, NULL, NULL } }; static info_lkp_t mge_sensitivity_info[] = { { 0, "normal", NULL }, { 1, "high", NULL }, { 2, "low", NULL }, { 0, NULL, NULL } }; static info_lkp_t mge_emergency_stop[] = { { 1, "Emergency stop!", NULL }, { 0, NULL, NULL } }; static info_lkp_t mge_wiring_fault[] = { { 1, "Wiring fault!", NULL }, { 0, NULL, NULL } }; static info_lkp_t mge_config_failure[] = { { 1, "Fatal EEPROM fault!", NULL }, { 0, NULL, NULL } }; static info_lkp_t mge_inverter_volthi[] = { { 1, "Inverter AC voltage too high!", NULL }, { 0, NULL, NULL } }; static info_lkp_t mge_inverter_voltlo[] = { { 1, "Inverter AC voltage too low!", NULL }, { 0, NULL, NULL } }; static info_lkp_t mge_short_circuit[] = { { 1, "Output short circuit!", NULL }, { 0, NULL, NULL } }; info_lkp_t mge_onbatt_info[] = { { 1, "!online", NULL }, { 0, "online", NULL }, { 0, NULL, NULL } }; /* allow limiting to ups.model = Protection Station, Ellipse Eco * and 3S (US 750 and AUS 700 only!) */ static const char *eaton_check_pegasus_fun(double value) { switch (mge_type & 0xFF00) /* Ignore model byte */ { case MGE_PEGASUS: break; case MGE_3S: /* Only consider non European models */ if (country_code != COUNTRY_EUROPE) break; default: return NULL; } snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.0f", value); return mge_scratch_buf; } static info_lkp_t pegasus_threshold_info[] = { { 10, "10", eaton_check_pegasus_fun }, { 25, "25", eaton_check_pegasus_fun }, { 60, "60", eaton_check_pegasus_fun }, { 0, NULL, NULL } }; /* allow limiting standard yes/no info (here, to enable ECO mode) to * ups.model = Protection Station, Ellipse Eco and 3S (US 750 and AUS 700 only!) * this allows to enable special flags used in hid_info_t entries (Ie RW) */ static const char *pegasus_yes_no_info_fun(double value) { switch (mge_type & 0xFF00) /* Ignore model byte */ { case MGE_PEGASUS: break; case MGE_3S: /* Only consider non European models */ if (country_code != COUNTRY_EUROPE) break; default: return NULL; } return (value == 0) ? "no" : "yes"; } /* Conversion back of yes/no info */ static double pegasus_yes_no_info_nuf(const char *value) { switch (mge_type & 0xFF00) /* Ignore model byte */ { case MGE_PEGASUS: break; case MGE_3S: /* Only consider non European models */ if (country_code != COUNTRY_EUROPE) break; default: return 0; } if (!strncmp(value, "yes", 3)) return 1; else return 0; } info_lkp_t pegasus_yes_no_info[] = { { 0, "no", pegasus_yes_no_info_fun, pegasus_yes_no_info_nuf }, { 1, "yes", pegasus_yes_no_info_fun, pegasus_yes_no_info_nuf }, { 0, NULL, NULL } }; /* Determine country using UPS.PowerSummary.Country. * If not present: * if PowerConverter.Output.Voltage >= 200 => "Europe" * else default to "US" */ static const char *eaton_check_country_fun(double value) { country_code = value; /* Return NULL, not to get the value published! */ return NULL; } static info_lkp_t eaton_check_country_info[] = { { 0, "dummy", eaton_check_country_fun }, { 0, NULL, NULL } }; /* Limit nominal output voltage according to HV or LV models */ static const char *nominal_output_voltage_fun(double value) { static long nominal = -1; if (nominal < 0) { nominal = value; } switch ((long)nominal) { /* LV models */ case 100: case 110: case 120: case 127: switch ((long)value) { case 100: case 110: case 120: case 127: break; default: return NULL; } break; /* line-interactive and online support 200/208 and 220/230/240*/ /* HV models */ /* 208V */ case 200: case 208: switch ((long)value) { case 200: case 208: break; /* 230V */ case 220: case 230: case 240: if ((mge_type & 0xFF00) >= MGE_DEFAULT) break; default: return NULL; } break; /* HV models */ /* 230V */ case 220: case 230: case 240: switch ((long)value) { case 200: case 208: /* line-interactive and online also support 200 / 208 V * So break on offline models */ if ((mge_type & 0xFF00) < MGE_DEFAULT) return NULL; /* FIXME: Some European models ("5130 RT 3000") also * support both HV values */ if (country_code == COUNTRY_EUROPE_208) break; case 220: case 230: case 240: break; default: return NULL; } break; default: upsdebugx(3, "%s: can't autodetect settable voltages from %g", __func__, value); } snprintf(mge_scratch_buf, sizeof(mge_scratch_buf), "%.0f", value); return mge_scratch_buf; } static info_lkp_t nominal_output_voltage_info[] = { /* line-interactive, starting with Evolution, support both HV values */ /* HV models */ /* 208V */ { 200, "200", nominal_output_voltage_fun }, { 208, "208", nominal_output_voltage_fun }, /* HV models */ /* 230V */ { 220, "220", nominal_output_voltage_fun }, { 230, "230", nominal_output_voltage_fun }, { 240, "240", nominal_output_voltage_fun }, /* LV models */ { 100, "100", nominal_output_voltage_fun }, { 110, "110", nominal_output_voltage_fun }, { 120, "120", nominal_output_voltage_fun }, { 127, "127", nominal_output_voltage_fun }, { 0, NULL, NULL } }; /* --------------------------------------------------------------- */ /* Vendor-specific usage table */ /* --------------------------------------------------------------- */ /* Eaton / MGE HID usage table */ static usage_lkp_t mge_usage_lkp[] = { { "Undefined", 0xffff0000 }, { "STS", 0xffff0001 }, { "Environment", 0xffff0002 }, { "Statistic", 0xffff0003 }, { "StatisticSystem", 0xffff0004 }, /* 0xffff0005-0xffff000f => Reserved */ { "Phase", 0xffff0010 }, { "PhaseID", 0xffff0011 }, { "Chopper", 0xffff0012 }, { "ChopperID", 0xffff0013 }, { "Inverter", 0xffff0014 }, { "InverterID", 0xffff0015 }, { "Rectifier", 0xffff0016 }, { "RectifierID", 0xffff0017 }, { "LCMSystem", 0xffff0018 }, { "LCMSystemID", 0xffff0019 }, { "LCMAlarm", 0xffff001a }, { "LCMAlarmID", 0xffff001b }, { "HistorySystem", 0xffff001c }, { "HistorySystemID", 0xffff001d }, { "Event", 0xffff001e }, { "EventID", 0xffff001f }, { "CircuitBreaker", 0xffff0020 }, { "TransferForbidden", 0xffff0021 }, { "OverallAlarm", 0xffff0022 }, /* renamed to Alarm in Eaton SW! */ { "Dephasing", 0xffff0023 }, { "BypassBreaker", 0xffff0024 }, { "PowerModule", 0xffff0025 }, { "PowerRate", 0xffff0026 }, { "PowerSource", 0xffff0027 }, { "CurrentPowerSource", 0xffff0028 }, { "RedundancyLevel", 0xffff0029 }, { "RedundancyLost", 0xffff002a }, { "NotificationStatus", 0xffff002b }, { "ProtectionLost", 0xffff002c }, { "ConfigurationFailure", 0xffff002d }, { "CompatibilityFailure", 0xffff002e }, /* 0xffff002e-0xffff003f => Reserved */ { "SwitchType", 0xffff0040 }, /* renamed to Type in Eaton SW! */ { "ConverterType", 0xffff0041 }, { "FrequencyConverterMode", 0xffff0042 }, { "AutomaticRestart", 0xffff0043 }, { "ForcedReboot", 0xffff0044 }, { "TestPeriod", 0xffff0045 }, { "EnergySaving", 0xffff0046 }, { "StartOnBattery", 0xffff0047 }, { "Schedule", 0xffff0048 }, { "DeepDischargeProtection", 0xffff0049 }, { "ShortCircuit", 0xffff004a }, { "ExtendedVoltageMode", 0xffff004b }, { "SensitivityMode", 0xffff004c }, { "RemainingCapacityLimitSetting", 0xffff004d }, { "ExtendedFrequencyMode", 0xffff004e }, { "FrequencyConverterModeSetting", 0xffff004f }, { "LowVoltageBoostTransfer", 0xffff0050 }, { "HighVoltageBoostTransfer", 0xffff0051 }, { "LowVoltageBuckTransfer", 0xffff0052 }, { "HighVoltageBuckTransfer", 0xffff0053 }, { "OverloadTransferEnable", 0xffff0054 }, { "OutOfToleranceTransferEnable", 0xffff0055 }, { "ForcedTransferEnable", 0xffff0056 }, { "LowVoltageBypassTransfer", 0xffff0057 }, { "HighVoltageBypassTransfer", 0xffff0058 }, { "FrequencyRangeBypassTransfer", 0xffff0059 }, { "LowVoltageEcoTransfer", 0xffff005a }, { "HighVoltageEcoTransfer", 0xffff005b }, { "FrequencyRangeEcoTransfer", 0xffff005c }, { "ShutdownTimer", 0xffff005d }, { "StartupTimer", 0xffff005e }, { "RestartLevel", 0xffff005f }, { "PhaseOutOfRange", 0xffff0060 }, { "CurrentLimitation", 0xffff0061 }, { "ThermalOverload", 0xffff0062 }, { "SynchroSource", 0xffff0063 }, { "FuseFault", 0xffff0064 }, { "ExternalProtectedTransfert", 0xffff0065 }, { "ExternalForcedTransfert", 0xffff0066 }, { "Compensation", 0xffff0067 }, { "EmergencyStop", 0xffff0068 }, { "PowerFactor", 0xffff0069 }, { "PeakFactor", 0xffff006a }, { "ChargerType", 0xffff006b }, { "HighPositiveDCBusVoltage", 0xffff006c }, { "LowPositiveDCBusVoltage", 0xffff006d }, { "HighNegativeDCBusVoltage", 0xffff006e }, { "LowNegativeDCBusVoltage", 0xffff006f }, { "FrequencyRangeTransfer", 0xffff0070 }, { "WiringFaultDetection", 0xffff0071 }, { "ControlStandby", 0xffff0072 }, { "ShortCircuitTolerance", 0xffff0073 }, { "VoltageTooHigh", 0xffff0074 }, { "VoltageTooLow", 0xffff0075 }, { "DCBusUnbalanced", 0xffff0076 }, { "FanFailure", 0xffff0077 }, { "WiringFault", 0xffff0078 }, { "Floating", 0xffff0079 }, { "OverCurrent", 0xffff007a }, { "RemainingActivePower", 0xffff007b }, { "Energy", 0xffff007c }, { "Threshold", 0xffff007d }, { "OverThreshold", 0xffff007e }, /* 0xffff007f => Reserved */ { "Sensor", 0xffff0080 }, { "LowHumidity", 0xffff0081 }, { "HighHumidity", 0xffff0082 }, { "LowTemperature", 0xffff0083 }, { "HighTemperature", 0xffff0084 }, { "ECOControl", 0xffff0085 }, { "Efficiency", 0xffff0086 }, { "ABMEnable", 0xffff0087 }, { "NegativeCurrent", 0xffff0088 }, { "AutomaticStart", 0xffff0089 }, /* 0xffff008a-0xffff008f => Reserved */ { "Count", 0xffff0090 }, { "Timer", 0xffff0091 }, { "Interval", 0xffff0092 }, { "TimerExpired", 0xffff0093 }, { "Mode", 0xffff0094 }, { "Country", 0xffff0095 }, { "State", 0xffff0096 }, { "Time", 0xffff0097 }, { "Code", 0xffff0098 }, { "DataValid", 0xffff0099 }, { "ToggleTimer", 0xffff009a }, { "BypassTransferDelay", 0xffff009b }, { "HysteresysVoltageTransfer", 0xffff009c }, { "SlewRate", 0xffff009d }, /* 0xffff009e-0xffff009f => Reserved */ { "PDU", 0xffff00a0 }, { "Breaker", 0xffff00a1 }, { "BreakerID", 0xffff00a2 }, { "OverVoltage", 0xffff00a3 }, { "Tripped", 0xffff00a4 }, { "OverEnergy", 0xffff00a5 }, { "OverHumidity", 0xffff00a6 }, { "ConfigurationReset", 0xffff00a7 }, /* renamed from LCDControl in Eaton SW! */ { "Level", 0xffff00a8 }, { "PDUType", 0xffff00a9 }, { "ReactivePower", 0xffff00aa }, { "Pole", 0xffff00ab }, { "PoleID", 0xffff00ac }, { "Reset", 0xffff00ad }, { "WatchdogReset", 0xffff00ae }, /* 0xffff00af-0xffff00df => Reserved */ { "COPIBridge", 0xffff00e0 }, /* 0xffff00e1-0xffff00ef => Reserved */ { "iModel", 0xffff00f0 }, { "iVersion", 0xffff00f1 }, { "iTechnicalLevel", 0xffff00f2 }, { "iPartNumber", 0xffff00f3 }, { "iReferenceNumber", 0xffff00f4 }, { "iGang", 0xffff00f5 }, /* 0xffff00f6-0xffff00ff => Reserved */ /* end of table */ { NULL, 0 } }; static usage_tables_t mge_utab[] = { mge_usage_lkp, hid_usage_lkp, NULL, }; /* --------------------------------------------------------------- */ /* Model Name formating entries */ /* --------------------------------------------------------------- */ typedef struct { const char *iProduct; const char *iModel; models_type_t type; /* enumerated model type */ const char *name; /* optional (defaults to " " if NULL) */ } models_name_t; /* * Do not remove models from this list, but instead comment them * out if not needed. This allows us to quickly add overrides for * specific models only, should this be needed. */ static models_name_t mge_model_names [] = { /* Ellipse models */ { "ELLIPSE", "300", MGE_DEFAULT_OFFLINE, "ellipse 300" }, { "ELLIPSE", "500", MGE_DEFAULT_OFFLINE, "ellipse 500" }, { "ELLIPSE", "650", MGE_DEFAULT_OFFLINE, "ellipse 650" }, { "ELLIPSE", "800", MGE_DEFAULT_OFFLINE, "ellipse 800" }, { "ELLIPSE", "1200", MGE_DEFAULT_OFFLINE, "ellipse 1200" }, /* Ellipse Premium models */ { "ellipse", "PR500", MGE_DEFAULT_OFFLINE, "ellipse premium 500" }, { "ellipse", "PR650", MGE_DEFAULT_OFFLINE, "ellipse premium 650" }, { "ellipse", "PR800", MGE_DEFAULT_OFFLINE, "ellipse premium 800" }, { "ellipse", "PR1200", MGE_DEFAULT_OFFLINE, "ellipse premium 1200" }, /* Ellipse "Pro" */ { "ELLIPSE", "600", MGE_DEFAULT_OFFLINE, "Ellipse 600" }, { "ELLIPSE", "750", MGE_DEFAULT_OFFLINE, "Ellipse 750" }, { "ELLIPSE", "1000", MGE_DEFAULT_OFFLINE, "Ellipse 1000" }, { "ELLIPSE", "1500", MGE_DEFAULT_OFFLINE, "Ellipse 1500" }, /* Ellipse MAX */ { "Ellipse MAX", "600", MGE_DEFAULT_OFFLINE, NULL }, { "Ellipse MAX", "850", MGE_DEFAULT_OFFLINE, NULL }, { "Ellipse MAX", "1100", MGE_DEFAULT_OFFLINE, NULL }, { "Ellipse MAX", "1500", MGE_DEFAULT_OFFLINE, NULL }, /* Protection Center */ { "PROTECTIONCENTER", "420", MGE_DEFAULT_OFFLINE, "Protection Center 420" }, { "PROTECTIONCENTER", "500", MGE_DEFAULT_OFFLINE, "Protection Center 500" }, { "PROTECTIONCENTER", "675", MGE_DEFAULT_OFFLINE, "Protection Center 675" }, /* Protection Station, supports Eco control */ { "Protection Station", "500", MGE_PEGASUS, NULL }, { "Protection Station", "650", MGE_PEGASUS, NULL }, { "Protection Station", "800", MGE_PEGASUS, NULL }, /* Ellipse ECO, also supports Eco control */ { "Ellipse ECO", "650", MGE_PEGASUS, NULL }, { "Ellipse ECO", "800", MGE_PEGASUS, NULL }, { "Ellipse ECO", "1200", MGE_PEGASUS, NULL }, { "Ellipse ECO", "1600", MGE_PEGASUS, NULL }, /* 3S, also supports Eco control on some models (AUS 700 and US 750)*/ { "3S", "450", MGE_DEFAULT_OFFLINE, NULL }, /* US only */ { "3S", "550", MGE_DEFAULT_OFFLINE, NULL }, /* US 120V + EU 230V + AUS 240V */ { "3S", "700", MGE_3S, NULL }, /* EU 230V + AUS 240V (w/ eco control) */ { "3S", "750", MGE_3S, NULL }, /* US 120V (w/ eco control) */ /* Evolution models */ { "Evolution", "500", MGE_DEFAULT, "Pulsar Evolution 500" }, { "Evolution", "800", MGE_DEFAULT, "Pulsar Evolution 800" }, { "Evolution", "1100", MGE_DEFAULT, "Pulsar Evolution 1100" }, { "Evolution", "1500", MGE_DEFAULT, "Pulsar Evolution 1500" }, { "Evolution", "2200", MGE_DEFAULT, "Pulsar Evolution 2200" }, { "Evolution", "3000", MGE_DEFAULT, "Pulsar Evolution 3000" }, { "Evolution", "3000XL", MGE_DEFAULT, "Pulsar Evolution 3000 XL" }, /* Newer Evolution models */ { "Evolution", "650", MGE_EVOLUTION_650, NULL }, { "Evolution", "850", MGE_EVOLUTION_850, NULL }, { "Evolution", "1150", MGE_EVOLUTION_1150, NULL }, { "Evolution", "S 1250", MGE_EVOLUTION_S_1250, NULL }, { "Evolution", "1550", MGE_EVOLUTION_1550, NULL }, { "Evolution", "S 1750", MGE_EVOLUTION_S_1750, NULL }, { "Evolution", "2000", MGE_EVOLUTION_2000, NULL }, { "Evolution", "S 2500", MGE_EVOLUTION_S_2500, NULL }, { "Evolution", "S 3000", MGE_EVOLUTION_S_3000, NULL }, /* Pulsar M models */ { "PULSAR M", "2200", MGE_PULSAR_M_2200, NULL }, { "PULSAR M", "3000", MGE_PULSAR_M_3000, NULL }, { "PULSAR M", "3000 XL", MGE_PULSAR_M_3000_XL, NULL }, /* Eaton'ified names */ { "EX", "2200", MGE_PULSAR_M_2200, NULL }, { "EX", "3000", MGE_PULSAR_M_3000, NULL }, { "EX", "3000 XL", MGE_PULSAR_M_3000, NULL }, /* Pulsar models (TBR) */ /* { "Pulsar", "700", MGE_DEFAULT, NULL }, */ /* { "Pulsar", "1000", MGE_DEFAULT, NULL }, */ /* { "Pulsar", "1500", MGE_DEFAULT, NULL }, */ /* { "Pulsar", "1000 RT2U", MGE_DEFAULT, NULL }, */ /* { "Pulsar", "1500 RT2U", MGE_DEFAULT, NULL }, */ /* Eaton'ified names (TBR) */ /* { "EX", "700", MGE_DEFAULT, NULL }, */ /* { "EX", "1000", MGE_DEFAULT, NULL }, */ /* { "EX", "1500", MGE_DEFAULT, NULL }, */ /* { "EX", "1000 RT2U", MGE_DEFAULT, NULL }, */ /* { "EX", "1500 RT2U", MGE_DEFAULT, NULL }, */ /* Pulsar MX models */ { "PULSAR", "MX4000", MGE_DEFAULT, "Pulsar MX 4000 RT" }, { "PULSAR", "MX5000", MGE_DEFAULT, "Pulsar MX 5000 RT" }, /* NOVA models */ { "NOVA AVR", "500", MGE_DEFAULT, "Nova 500 AVR" }, { "NOVA AVR", "600", MGE_DEFAULT, "Nova 600 AVR" }, { "NOVA AVR", "625", MGE_DEFAULT, "Nova 625 AVR" }, { "NOVA AVR", "1100", MGE_DEFAULT, "Nova 1100 AVR" }, { "NOVA AVR", "1250", MGE_DEFAULT, "Nova 1250 AVR" }, /* EXtreme C (EMEA) */ { "EXtreme", "700C", MGE_DEFAULT, "Pulsar EXtreme 700C" }, { "EXtreme", "1000C", MGE_DEFAULT, "Pulsar EXtreme 1000C" }, { "EXtreme", "1500C", MGE_DEFAULT, "Pulsar EXtreme 1500C" }, { "EXtreme", "1500CCLA", MGE_DEFAULT, "Pulsar EXtreme 1500C CLA" }, { "EXtreme", "2200C", MGE_DEFAULT, "Pulsar EXtreme 2200C" }, { "EXtreme", "3200C", MGE_DEFAULT, "Pulsar EXtreme 3200C" }, /* EXtreme C (USA, aka "EX RT") */ { "EX", "700RT", MGE_DEFAULT, "Pulsar EX 700 RT" }, { "EX", "1000RT", MGE_DEFAULT, "Pulsar EX 1000 RT" }, { "EX", "1500RT", MGE_DEFAULT, "Pulsar EX 1500 RT" }, { "EX", "2200RT", MGE_DEFAULT, "Pulsar EX 2200 RT" }, { "EX", "3200RT", MGE_DEFAULT, "Pulsar EX 3200 RT" }, /* Comet EX RT three phased */ { "EX", "5RT31", MGE_DEFAULT, "EX 5 RT 3:1" }, { "EX", "7RT31", MGE_DEFAULT, "EX 7 RT 3:1" }, { "EX", "11RT31", MGE_DEFAULT, "EX 11 RT 3:1" }, /* Comet EX RT mono phased */ { "EX", "5RT", MGE_DEFAULT, "EX 5 RT" }, { "EX", "7RT", MGE_DEFAULT, "EX 7 RT" }, { "EX", "11RT", MGE_DEFAULT, "EX 11 RT" }, /* Galaxy 3000 */ { "GALAXY", "3000_10", MGE_DEFAULT, "Galaxy 3000 10 kVA" }, { "GALAXY", "3000_15", MGE_DEFAULT, "Galaxy 3000 15 kVA" }, { "GALAXY", "3000_20", MGE_DEFAULT, "Galaxy 3000 20 kVA" }, { "GALAXY", "3000_30", MGE_DEFAULT, "Galaxy 3000 30 kVA" }, /* end of structure. */ { NULL } }; /* --------------------------------------------------------------- */ /* Data lookup table (HID <-> NUT) */ /* --------------------------------------------------------------- */ static hid_info_t mge_hid2nut[] = { /* Device collection */ /* Just declared to call *hid2info */ { "device.country", ST_FLAG_STRING, 20, "UPS.PowerSummary.Country", NULL, "Europe", HU_FLAG_STATIC, eaton_check_country_info }, /* Battery page */ { "battery.charge", 0, 0, "UPS.PowerSummary.RemainingCapacity", NULL, "%.0f", 0, NULL }, { "battery.charge.low", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerSummary.RemainingCapacityLimitSetting", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "battery.charge.low", 0, 0, "UPS.PowerSummary.RemainingCapacityLimit", NULL, "%.0f", HU_FLAG_STATIC , NULL }, /* Read only */ { "battery.charge.restart", ST_FLAG_RW | ST_FLAG_STRING, 3, "UPS.PowerSummary.RestartLevel", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "battery.capacity", 0, 0, "UPS.BatterySystem.Battery.DesignCapacity", NULL, "%s", HU_FLAG_STATIC, mge_battery_capacity }, /* conversion needed from As to Ah */ { "battery.runtime", 0, 0, "UPS.PowerSummary.RunTimeToEmpty", NULL, "%.0f", 0, NULL }, { "battery.runtime.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.RemainingTimeLimit", NULL, "%.0f", 0, NULL }, { "battery.runtime.elapsed", 0, 0, "UPS.StatisticSystem.Input.[1].Statistic.[1].Time", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL }, { "battery.runtime.low", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.RemainingTimeLimit", NULL, "%.0f", 0, NULL }, { "battery.temperature", 0, 0, "UPS.BatterySystem.Battery.Temperature", NULL, "%s", 0, kelvin_celsius_conversion }, { "battery.type", 0, 0, "UPS.PowerSummary.iDeviceChemistry", NULL, "%s", HU_FLAG_STATIC, stringid_conversion }, { "battery.voltage", 0, 0, "UPS.BatterySystem.Voltage", NULL, "%.1f", 0, NULL }, { "battery.voltage", 0, 0, "UPS.PowerSummary.Voltage", NULL, "%s", 0, mge_battery_voltage }, { "battery.voltage.nominal", 0, 0, "UPS.BatterySystem.ConfigVoltage", NULL, "%.0f", HU_FLAG_STATIC, NULL }, { "battery.voltage.nominal", 0, 0, "UPS.PowerSummary.ConfigVoltage", NULL, "%s", HU_FLAG_STATIC, mge_battery_voltage_nominal }, { "battery.protection", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.BatterySystem.Battery.DeepDischargeProtection", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info }, { "battery.energysave", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Input.[3].EnergySaving", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info }, /* UPS page */ { "ups.efficiency", 0, 0, "UPS.PowerConverter.Output.Efficiency", NULL, "%.0f", 0, NULL }, { "ups.firmware", 0, 0, "UPS.PowerSummary.iVersion", NULL, "%s", HU_FLAG_STATIC, stringid_conversion }, { "ups.load", 0, 0, "UPS.PowerSummary.PercentLoad", NULL, "%.0f", 0, NULL }, { "ups.load.high", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.Flow.[4].ConfigPercentLoad", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "ups.delay.start", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.DelayBeforeStartup", NULL, DEFAULT_ONDELAY, HU_FLAG_ABSENT, NULL}, { "ups.delay.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.DelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_FLAG_ABSENT, NULL}, { "ups.timer.start", 0, 0, "UPS.PowerSummary.DelayBeforeStartup", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL}, { "ups.timer.shutdown", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL}, { "ups.timer.reboot", 0, 0, "UPS.PowerSummary.DelayBeforeReboot", NULL, "%.0f", HU_FLAG_QUICK_POLL, NULL}, { "ups.test.result", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "%s", 0, test_read_info }, { "ups.test.interval", ST_FLAG_RW | ST_FLAG_STRING, 8, "UPS.BatterySystem.Battery.TestPeriod", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "ups.beeper.status", 0 ,0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "%s", HU_FLAG_SEMI_STATIC, beeper_info }, { "ups.temperature", 0, 0, "UPS.PowerSummary.Temperature", NULL, "%s", 0, kelvin_celsius_conversion }, { "ups.power", 0, 0, "UPS.PowerConverter.Output.ApparentPower", NULL, "%.0f", 0, NULL }, { "ups.L1.power", 0, 0, "UPS.PowerConverter.Output.Phase.[1].ApparentPower", NULL, "%.0f", 0, NULL }, { "ups.L2.power", 0, 0, "UPS.PowerConverter.Output.Phase.[2].ApparentPower", NULL, "%.0f", 0, NULL }, { "ups.L3.power", 0, 0, "UPS.PowerConverter.Output.Phase.[3].ApparentPower", NULL, "%.0f", 0, NULL }, { "ups.power.nominal", 0, 0, "UPS.Flow.[4].ConfigApparentPower", NULL, "%.0f", HU_FLAG_STATIC, NULL }, { "ups.realpower", 0, 0, "UPS.PowerConverter.Output.ActivePower", NULL, "%.0f", 0, NULL }, { "ups.L1.realpower", 0, 0, "UPS.PowerConverter.Output.Phase.[1].ActivePower", NULL, "%.0f", 0, NULL }, { "ups.L2.realpower", 0, 0, "UPS.PowerConverter.Output.Phase.[2].ActivePower", NULL, "%.0f", 0, NULL }, { "ups.L3.realpower", 0, 0, "UPS.PowerConverter.Output.Phase.[3].ActivePower", NULL, "%.0f", 0, NULL }, { "ups.realpower.nominal", 0, 0, "UPS.Flow.[4].ConfigActivePower", NULL, "%.0f", HU_FLAG_STATIC, NULL }, { "ups.start.auto", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Input.[1].AutomaticRestart", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info }, { "ups.start.battery", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Input.[3].StartOnBattery", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info }, { "ups.start.reboot", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.ForcedReboot", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info }, { "ups.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.PresentStatus.Switchable", NULL, "%s", HU_FLAG_SEMI_STATIC | HU_FLAG_ENUM, eaton_enable_disable_info }, #ifdef HAVE_STRPTIME { "ups.date", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.Time", NULL, "%s", 0, mge_date_conversion }, { "ups.time", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerSummary.Time", NULL, "%s", 0, mge_time_conversion }, #else { "ups.date", 0, 0, "UPS.PowerSummary.Time", NULL, "%s", 0, mge_date_conversion }, { "ups.time", 0, 0, "UPS.PowerSummary.Time", NULL, "%s", 0, mge_time_conversion }, #endif /* HAVE_STRPTIME */ { "ups.type", 0, 0, "UPS.PowerConverter.ConverterType", NULL, "%s", HU_FLAG_STATIC, mge_upstype_conversion }, /* Special case: boolean values that are mapped to ups.status and ups.alarm */ { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.ACPresent", NULL, NULL, HU_FLAG_QUICK_POLL, online_info }, { "BOOL", 0, 0, "UPS.PowerConverter.Input.[3].PresentStatus.Used", NULL, NULL, 0, mge_onbatt_info }, { "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.Used", NULL, NULL, 0, online_info }, { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Discharging", NULL, NULL, HU_FLAG_QUICK_POLL, discharging_info }, { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Charging", NULL, NULL, HU_FLAG_QUICK_POLL, charging_info }, /* FIXME: on Dell, the above requires an "AND" with "UPS.BatterySystem.Charger.Mode = 1" */ { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit", NULL, NULL, HU_FLAG_QUICK_POLL, lowbatt_info }, /* Output overload, Level 1 (FIXME: add the level?) */ { "BOOL", 0, 0, "UPS.PowerConverter.Output.Overload.[1].PresentStatus.OverThreshold", NULL, NULL, 0, overload_info }, /* Output overload, Level 2 (FIXME: add the level?) */ { "BOOL", 0, 0, "UPS.PowerConverter.Output.Overload.[2].PresentStatus.OverThreshold", NULL, NULL, 0, overload_info }, /* Output overload, Level 3 (FIXME: add the level?) */ { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Overload", NULL, NULL, 0, overload_info }, { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.NeedReplacement", NULL, NULL, 0, replacebatt_info }, /* FIXME: on Dell, the above requires an "AND" with "UPS.BatterySystem.Battery.Test = 3 " */ { "BOOL", 0, 0, "UPS.LCMSystem.LCMAlarm.[2].PresentStatus.TimerExpired", NULL, NULL, 0, replacebatt_info }, { "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.Buck", NULL, NULL, 0, trim_info }, { "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.Boost", NULL, NULL, 0, boost_info }, { "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.VoltageOutOfRange", NULL, NULL, 0, vrange_info }, { "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.FrequencyOutOfRange", NULL, NULL, 0, frange_info }, { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.Good", NULL, NULL, 0, off_info }, #if 0 /* TODO: UPS.BatterySystem.Charger.PresentStatus.Used is related to ABM */ { "BOOL", 0, 0, "UPS.BatterySystem.Charger.PresentStatus.Used", NULL, NULL, 0, off_info }, /* FIXME: on Dell, the above requires an "AND" with "UPS.BatterySystem.Charger.Mode = 4 (ABM Resting)" */ #endif { "BOOL", 0, 0, "UPS.PowerConverter.Input.[2].PresentStatus.Used", NULL, NULL, 0, bypass_auto_info }, /* Automatic bypass */ { "BOOL", 0, 0, "UPS.PowerConverter.Input.[4].PresentStatus.Used", NULL, NULL, 0, bypass_manual_info }, /* Manual bypass */ { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.FanFailure", NULL, NULL, 0, fanfail_info }, { "BOOL", 0, 0, "UPS.BatterySystem.Battery.PresentStatus.Present", NULL, NULL, 0, nobattery_info }, { "BOOL", 0, 0, "UPS.BatterySystem.Charger.PresentStatus.InternalFailure", NULL, NULL, 0, chargerfail_info }, { "BOOL", 0, 0, "UPS.BatterySystem.Charger.PresentStatus.VoltageTooHigh", NULL, NULL, 0, battvolthi_info }, { "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.VoltageTooHigh", NULL, NULL, 0, battvolthi_info }, /* Battery DC voltage too high! */ { "BOOL", 0, 0, "UPS.BatterySystem.Battery.PresentStatus.VoltageTooHigh", NULL, NULL, 0, battvolthi_info }, { "BOOL", 0, 0, "UPS.BatterySystem.Charger.PresentStatus.VoltageTooLow", NULL, NULL, 0, battvoltlo_info }, { "BOOL", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.VoltageTooLow", NULL, NULL, 0, mge_onbatt_info }, { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.InternalFailure", NULL, NULL, 0, commfault_info }, { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.OverTemperature", NULL, NULL, 0, overheat_info }, { "BOOL", 0, 0, "UPS.PowerSummary.PresentStatus.ShutdownImminent", NULL, NULL, 0, shutdownimm_info }, /* Vendor specific ups.alarm */ { "ups.alarm", 0, 0, "UPS.PowerSummary.PresentStatus.EmergencyStop", NULL, NULL, 0, mge_emergency_stop }, { "ups.alarm", 0, 0, "UPS.PowerConverter.Input.[1].PresentStatus.WiringFault", NULL, NULL, 0, mge_wiring_fault }, { "ups.alarm", 0, 0, "UPS.PowerSummary.PresentStatus.ConfigurationFailure", NULL, NULL, 0, mge_config_failure }, { "ups.alarm", 0, 0, "UPS.PowerConverter.Inverter.PresentStatus.VoltageTooHigh", NULL, NULL, 0, mge_inverter_volthi }, { "ups.alarm", 0, 0, "UPS.PowerConverter.Inverter.PresentStatus.VoltageTooLow", NULL, NULL, 0, mge_inverter_voltlo }, { "ups.alarm", 0, 0, "UPS.PowerConverter.Output.PresentStatus.ShortCircuit", NULL, NULL, 0, mge_short_circuit }, /* Input page */ { "input.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Voltage", NULL, "%.1f", 0, NULL }, { "input.L1-N.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[1].Voltage", NULL, "%.1f", 0, NULL }, { "input.L2-N.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[2].Voltage", NULL, "%.1f", 0, NULL }, { "input.L3-N.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[3].Voltage", NULL, "%.1f", 0, NULL }, { "input.L1-L2.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[12].Voltage", NULL, "%.1f", 0, NULL }, { "input.L2-L3.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[23].Voltage", NULL, "%.1f", 0, NULL }, { "input.L3-L1.voltage", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[31].Voltage", NULL, "%.1f", 0, NULL }, { "input.voltage.nominal", 0, 0, "UPS.Flow.[1].ConfigVoltage", NULL, "%.0f", HU_FLAG_STATIC, NULL }, { "input.current", 0, 0, "UPS.PowerConverter.Input.[1].Current", NULL, "%.2f", 0, NULL }, { "input.L1.current", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[1].Current", NULL, "%.1f", 0, NULL }, { "input.L2.current", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[2].Current", NULL, "%.1f", 0, NULL }, { "input.L3.current", 0, 0, "UPS.PowerConverter.Input.[1].Phase.[3].Current", NULL, "%.1f", 0, NULL }, { "input.current.nominal", 0, 0, "UPS.Flow.[1].ConfigCurrent", NULL, "%.2f", HU_FLAG_STATIC, NULL }, { "input.frequency", 0, 0, "UPS.PowerConverter.Input.[1].Frequency", NULL, "%.1f", 0, NULL }, { "input.frequency.nominal", 0, 0, "UPS.Flow.[1].ConfigFrequency", NULL, "%.0f", HU_FLAG_STATIC, NULL }, /* same as "input.transfer.boost.low" */ { "input.transfer.low", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.LowVoltageTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "input.transfer.boost.low", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.LowVoltageBoostTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "input.transfer.boost.high", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.HighVoltageBoostTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "input.transfer.trim.low", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.LowVoltageBuckTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, /* same as "input.transfer.trim.high" */ { "input.transfer.high", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.HighVoltageTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "input.transfer.trim.high", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.HighVoltageBuckTransfer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "input.sensitivity", ST_FLAG_RW | ST_FLAG_STRING, 10, "UPS.PowerConverter.Output.SensitivityMode", NULL, "%s", HU_FLAG_SEMI_STATIC, mge_sensitivity_info }, { "input.voltage.extended", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.ExtendedVoltageMode", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info }, { "input.frequency.extended", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.PowerConverter.Output.ExtendedFrequencyMode", NULL, "%s", HU_FLAG_SEMI_STATIC, yes_no_info }, /* Bypass page */ { "input.bypass.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Voltage", NULL, "%.1f", 0, NULL }, { "input.bypass.L1-N.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[1].Voltage", NULL, "%.1f", 0, NULL }, { "input.bypass.L2-N.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[2].Voltage", NULL, "%.1f", 0, NULL }, { "input.bypass.L3-N.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[3].Voltage", NULL, "%.1f", 0, NULL }, { "input.bypass.L1-L2.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[12].Voltage", NULL, "%.1f", 0, NULL }, { "input.bypass.L2-L3.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[23].Voltage", NULL, "%.1f", 0, NULL }, { "input.bypass.L3-L1.voltage", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[31].Voltage", NULL, "%.1f", 0, NULL }, { "input.bypass.voltage.nominal", 0, 0, "UPS.Flow.[2].ConfigVoltage", NULL, "%.0f", HU_FLAG_STATIC, NULL }, { "input.bypass.current", 0, 0, "UPS.PowerConverter.Input.[2].Current", NULL, "%.2f", 0, NULL }, { "input.bypass.L1.current", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[1].Current", NULL, "%.1f", 0, NULL }, { "input.bypass.L2.current", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[2].Current", NULL, "%.1f", 0, NULL }, { "input.bypass.L3.current", 0, 0, "UPS.PowerConverter.Input.[2].Phase.[3].Current", NULL, "%.1f", 0, NULL }, { "input.bypass.current.nominal", 0, 0, "UPS.Flow.[2].ConfigCurrent", NULL, "%.2f", HU_FLAG_STATIC, NULL }, { "input.bypass.frequency", 0, 0, "UPS.PowerConverter.Input.[2].Frequency", NULL, "%.1f", 0, NULL }, { "input.bypass.frequency.nominal", 0, 0, "UPS.Flow.[2].ConfigFrequency", NULL, "%.0f", HU_FLAG_STATIC, NULL }, /* Output page */ { "output.voltage", 0, 0, "UPS.PowerConverter.Output.Voltage", NULL, "%.1f", 0, NULL }, { "output.L1-N.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[1].Voltage", NULL, "%.1f", 0, NULL }, { "output.L2-N.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[2].Voltage", NULL, "%.1f", 0, NULL }, { "output.L3-N.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[3].Voltage", NULL, "%.1f", 0, NULL }, { "output.L1-L2.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[12].Voltage", NULL, "%.1f", 0, NULL }, { "output.L2-L3.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[23].Voltage", NULL, "%.1f", 0, NULL }, { "output.L3-L1.voltage", 0, 0, "UPS.PowerConverter.Output.Phase.[31].Voltage", NULL, "%.1f", 0, NULL }, { "output.voltage.nominal", ST_FLAG_RW | ST_FLAG_STRING, 3, "UPS.Flow.[4].ConfigVoltage", NULL, "%.0f", HU_FLAG_SEMI_STATIC | HU_FLAG_ENUM, nominal_output_voltage_info }, { "output.current", 0, 0, "UPS.PowerConverter.Output.Current", NULL, "%.2f", 0, NULL }, { "output.L1.current", 0, 0, "UPS.PowerConverter.Output.Phase.[1].Current", NULL, "%.1f", 0, NULL }, { "output.L2.current", 0, 0, "UPS.PowerConverter.Output.Phase.[2].Current", NULL, "%.1f", 0, NULL }, { "output.L3.current", 0, 0, "UPS.PowerConverter.Output.Phase.[3].Current", NULL, "%.1f", 0, NULL }, { "output.current.nominal", 0, 0, "UPS.Flow.[4].ConfigCurrent", NULL, "%.2f", 0, NULL }, { "output.frequency", 0, 0, "UPS.PowerConverter.Output.Frequency", NULL, "%.1f", 0, NULL }, /* FIXME: can be RW (50/60) (or on .nominal)? */ { "output.frequency.nominal", 0, 0, "UPS.Flow.[4].ConfigFrequency", NULL, "%.0f", HU_FLAG_STATIC, NULL }, { "output.powerfactor", 0, 0, "UPS.PowerConverter.Output.PowerFactor", NULL, "%s", 0, mge_powerfactor_conversion }, /* Outlet page (using MGE UPS SYSTEMS - PowerShare technology) */ { "outlet.id", 0, 0, "UPS.OutletSystem.Outlet.[1].OutletID", NULL, "%.0f", HU_FLAG_STATIC, NULL }, { "outlet.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, "UPS.OutletSystem.Outlet.[1].OutletID", NULL, "Main Outlet", HU_FLAG_ABSENT, NULL }, { "outlet.switchable", 0, 0, "UPS.OutletSystem.Outlet.[1].PresentStatus.Switchable", NULL, "%s", HU_FLAG_STATIC, yes_no_info }, /* On Protection Station, the line below is the power consumption threshold * on the master outlet used to automatically power off the slave outlets. * Values: 10, 25 (default) or 60 VA. */ { "outlet.power", ST_FLAG_RW | ST_FLAG_STRING, 6, "UPS.OutletSystem.Outlet.[1].ConfigApparentPower", NULL, "%s", HU_FLAG_SEMI_STATIC | HU_FLAG_ENUM, pegasus_threshold_info }, { "outlet.power", 0, 0, "UPS.OutletSystem.Outlet.[1].ApparentPower", NULL, "%.0f", 0, NULL }, { "outlet.realpower", 0, 0, "UPS.OutletSystem.Outlet.[1].ActivePower", NULL, "%.0f", 0, NULL }, { "outlet.current", 0, 0, "UPS.OutletSystem.Outlet.[1].Current", NULL, "%.2f", 0, NULL }, { "outlet.powerfactor", 0, 0, "UPS.OutletSystem.Outlet.[1].PowerFactor", NULL, "%.2f", 0, NULL }, /* "%s", 0, mge_powerfactor_conversion }, */ /* First outlet */ { "outlet.1.id", 0, 0, "UPS.OutletSystem.Outlet.[2].OutletID", NULL, "%.0f", HU_FLAG_STATIC, NULL }, { "outlet.1.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, "UPS.OutletSystem.Outlet.[2].OutletID", NULL, "PowerShare Outlet 1", HU_FLAG_ABSENT, NULL }, { "outlet.1.switchable", 0, 0, "UPS.OutletSystem.Outlet.[2].PresentStatus.Switchable", NULL, "%s", HU_FLAG_STATIC, yes_no_info }, { "outlet.1.status", 0, 0, "UPS.OutletSystem.Outlet.[2].PresentStatus.SwitchOn/Off", NULL, "%s", 0, on_off_info }, /* For low end models, with 1 non backup'ed outlet */ { "outlet.1.status", 0, 0, "UPS.PowerSummary.PresentStatus.ACPresent", NULL, "%s", 0, on_off_info }, /* FIXME: change to outlet.1.battery.charge.low, as in mge-xml.c?! */ { "outlet.1.autoswitch.charge.low", ST_FLAG_RW | ST_FLAG_STRING, 3, "UPS.OutletSystem.Outlet.[2].RemainingCapacityLimit", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "outlet.1.delay.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.OutletSystem.Outlet.[2].ShutdownTimer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "outlet.1.delay.start", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.OutletSystem.Outlet.[2].StartupTimer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "outlet.1.power", 0, 0, "UPS.OutletSystem.Outlet.[2].ApparentPower", NULL, "%.0f", 0, NULL }, { "outlet.1.realpower", 0, 0, "UPS.OutletSystem.Outlet.[2].ActivePower", NULL, "%.0f", 0, NULL }, { "outlet.1.current", 0, 0, "UPS.OutletSystem.Outlet.[2].Current", NULL, "%.2f", 0, NULL }, { "outlet.1.powerfactor", 0, 0, "UPS.OutletSystem.Outlet.[2].PowerFactor", NULL, "%.2f", 0, NULL }, /* "%s", 0, mge_powerfactor_conversion }, */ /* Second outlet */ { "outlet.2.id", 0, 0, "UPS.OutletSystem.Outlet.[3].OutletID", NULL, "%.0f", HU_FLAG_STATIC, NULL }, { "outlet.2.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, "UPS.OutletSystem.Outlet.[3].OutletID", NULL, "PowerShare Outlet 2", HU_FLAG_ABSENT, NULL }, /* needed for Pegasus to enable master/slave mode: * FIXME: rename to something more suitable (outlet.?) */ { "outlet.2.switchable", ST_FLAG_RW | ST_FLAG_STRING, 3, "UPS.OutletSystem.Outlet.[3].PresentStatus.Switchable", NULL, "%s", HU_FLAG_SEMI_STATIC, pegasus_yes_no_info }, /* Generic version (RO) for other models */ { "outlet.2.switchable", 0, 0, "UPS.OutletSystem.Outlet.[3].PresentStatus.Switchable", NULL, "%s", 0, yes_no_info }, { "outlet.2.status", 0, 0, "UPS.OutletSystem.Outlet.[3].PresentStatus.SwitchOn/Off", NULL, "%s", 0, on_off_info }, { "outlet.2.autoswitch.charge.low", ST_FLAG_RW | ST_FLAG_STRING, 3, "UPS.OutletSystem.Outlet.[3].RemainingCapacityLimit", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "outlet.2.delay.shutdown", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.OutletSystem.Outlet.[3].ShutdownTimer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "outlet.2.delay.start", ST_FLAG_RW | ST_FLAG_STRING, 5, "UPS.OutletSystem.Outlet.[3].StartupTimer", NULL, "%.0f", HU_FLAG_SEMI_STATIC, NULL }, { "outlet.2.power", 0, 0, "UPS.OutletSystem.Outlet.[3].ApparentPower", NULL, "%.0f", 0, NULL }, { "outlet.2.realpower", 0, 0, "UPS.OutletSystem.Outlet.[3].ActivePower", NULL, "%.0f", 0, NULL }, { "outlet.2.current", 0, 0, "UPS.OutletSystem.Outlet.[3].Current", NULL, "%.2f", 0, NULL }, { "outlet.2.powerfactor", 0, 0, "UPS.OutletSystem.Outlet.[3].PowerFactor", NULL, "%.2f", 0, NULL }, /* "%s", 0, mge_powerfactor_conversion }, */ /* instant commands. */ /* splited into subset while waiting for extradata support * ie: test.battery.start quick */ { "test.battery.start.quick", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "1", HU_TYPE_CMD, NULL }, { "test.battery.start.deep", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "2", HU_TYPE_CMD, NULL }, { "test.battery.stop", 0, 0, "UPS.BatterySystem.Battery.Test", NULL, "3", HU_TYPE_CMD, NULL }, { "load.off.delay", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, DEFAULT_OFFDELAY, HU_TYPE_CMD, NULL }, { "load.on.delay", 0, 0, "UPS.PowerSummary.DelayBeforeStartup", NULL, DEFAULT_ONDELAY, HU_TYPE_CMD, NULL }, { "shutdown.stop", 0, 0, "UPS.PowerSummary.DelayBeforeShutdown", NULL, "-1", HU_TYPE_CMD, NULL }, { "shutdown.reboot", 0, 0, "UPS.PowerSummary.DelayBeforeReboot", NULL, "10", HU_TYPE_CMD, NULL}, { "beeper.off", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "1", HU_TYPE_CMD, NULL }, { "beeper.on", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "2", HU_TYPE_CMD, NULL }, { "beeper.mute", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "3", HU_TYPE_CMD, NULL }, { "beeper.disable", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "1", HU_TYPE_CMD, NULL }, { "beeper.enable", 0, 0, "UPS.PowerSummary.AudibleAlarmControl", NULL, "2", HU_TYPE_CMD, NULL }, /* Command for the outlet collection */ { "outlet.1.load.off", 0, 0, "UPS.OutletSystem.Outlet.[2].DelayBeforeShutdown", NULL, "0", HU_TYPE_CMD, NULL }, { "outlet.1.load.on", 0, 0, "UPS.OutletSystem.Outlet.[2].DelayBeforeStartup", NULL, "0", HU_TYPE_CMD, NULL }, { "outlet.2.load.off", 0, 0, "UPS.OutletSystem.Outlet.[3].DelayBeforeShutdown", NULL, "0", HU_TYPE_CMD, NULL }, { "outlet.2.load.on", 0, 0, "UPS.OutletSystem.Outlet.[3].DelayBeforeStartup", NULL, "0", HU_TYPE_CMD, NULL }, /* end of structure. */ { NULL } }; /* * All the logic for finely formatting the MGE model name and device * type matching (used for device specific values or corrections). * Returns pointer to (dynamically allocated) model name. */ static char *get_model_name(const char *iProduct, const char *iModel) { models_name_t *model = NULL; upsdebugx(2, "get_model_name(%s, %s)\n", iProduct, iModel); /* Search for device type and formatting rules */ for (model = mge_model_names; model->iProduct; model++) { if(model->name) { upsdebugx(2, "comparing with: %s", model->name); } else { upsdebugx(2, "comparing with: %s %s", model->iProduct, model->iModel); } if (strcmp(iProduct, model->iProduct)) { continue; } if (strcmp(iModel, model->iModel)) { continue; } mge_type = model->type; break; } if (!model->name) { /* * Model not found or NULL (use default) so construct * model name by concatenation of iProduct and iModel */ char buf[SMALLBUF]; snprintf(buf, sizeof(buf), "%s %s", iProduct, iModel); return strdup(buf); } return strdup(model->name); } static const char *mge_format_model(HIDDevice_t *hd) { char product[SMALLBUF]; char model[SMALLBUF]; double value; /* Dell has already a fully formatted name in iProduct */ if (hd->VendorID == DELL_VENDORID) { return hd->Product; } /* Get iProduct and iModel strings */ snprintf(product, sizeof(product), "%s", hd->Product ? hd->Product : "unknown"); HIDGetItemString(udev, "UPS.PowerSummary.iModel", model, sizeof(model), mge_utab); /* Fallback to ConfigApparentPower */ if ((strlen(model) < 1) && (HIDGetItemValue(udev, "UPS.Flow.[4].ConfigApparentPower", &value, mge_utab) == 1 )) { snprintf(model, sizeof(model), "%i", (int)value); } if (strlen(model) > 0) { free(hd->Product); hd->Product = get_model_name(product, model); } return hd->Product; } static const char *mge_format_mfr(HIDDevice_t *hd) { return hd->Vendor ? hd->Vendor : "Eaton"; } static const char *mge_format_serial(HIDDevice_t *hd) { return hd->Serial; } /* this function allows the subdriver to "claim" a device: return 1 if * the device is supported by this subdriver, else 0. */ static int mge_claim(HIDDevice_t *hd) { #ifndef SHUT_MODE int status = is_usb_device_supported(mge_usb_device_table, hd); switch (status) { case POSSIBLY_SUPPORTED: switch (hd->VendorID) { case HP_VENDORID: case DELL_VENDORID: /* by default, reject, unless the productid option is given */ if (getval("productid")) { return 1; } /* * this vendor makes lots of USB devices that are * not a UPS, so don't use possibly_supported here */ return 0; default: /* Valid for Eaton */ /* by default, reject, unless the productid option is given */ if (getval("productid")) { return 1; } possibly_supported("Eaton / MGE", hd); return 0; } case SUPPORTED: return 1; case NOT_SUPPORTED: default: return 0; } #else return 1; #endif } subdriver_t mge_subdriver = { MGE_HID_VERSION, mge_claim, mge_utab, mge_hid2nut, mge_format_model, mge_format_mfr, mge_format_serial, };