'\" t
.\" Title: solis
.\" Author: [see the "AUTHOR" section]
.\" Generator: DocBook XSL Stylesheets v1.76.1
.\" Date: 02/15/2014
.\" Manual: NUT Manual
.\" Source: Network UPS Tools 2.7.1.5
.\" Language: English
.\"
.TH "SOLIS" "8" "02/15/2014" "Network UPS Tools 2\&.7\&.1\&." "NUT Manual"
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
solis \- Driver for Brazilian Microsol SOLIS UPS equipment
.SH "NOTE"
.sp
This man page only documents the hardware\-specific features of the solis driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&.
.SH "SUPPORTED HARDWARE"
.sp
This driver has been tested with :
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Solis 1000 VA
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Solis 1500 VA
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Solis 2000 VA
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
Solis 3000 VA
.RE
.sp
All Solis models are sinusoidal on\-line
.SH "EXTRA ARGUMENTS"
.sp
This driver support the following extra optional settings in the \fBups.conf\fR(5)\&.
.sp
\fBbattext = n\fR \- (default = 0, no extra battery, where n = Ampere*hour )
.sp
\fBprgshut = 1\fR \- (default = 0, no programable shutdown )
.SH "COMMANDS"
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
shutdown\&.return \- Shut down in \&.3 minutes and restart in \&.3 minutes
.RE
.sp
.RS 4
.ie n \{\
\h'-04'\(bu\h'+03'\c
.\}
.el \{\
.sp -1
.IP \(bu 2.3
.\}
shutdown\&.stayoff \- Shut down in \&.3 minutes and do not return
.RE
.SH "AUTHOR"
.sp
Silvino B\&. Magalhães
.SH "SEE ALSO"
.SS "The core driver:"
.sp
\fBnutupsdrv\fR(8)
.SS "Internet resources:"
.sp
The NUT (Network UPS Tools) home page: http://www\&.networkupstools\&.org/