#! /bin/sh ### BEGIN INIT INFO # Provides: nut # Required-Start: $local_fs $syslog $network $remote_fs udev # Required-Stop: $local_fs $syslog $network $remote_fs udev # Default-Start: 2 3 4 5 # Default-Stop: 0 1 6 # Short-Description: Network UPS Tools initscript # Description: This script take care of starting and stopping the # Network UPS Tools components. When needed, it also # handle the UPS hardware shutdown. ### END INIT INFO # Author: Arnaud Quette PATH=/sbin:/usr/sbin:/bin:/usr/bin:/usr/local/sbin:/usr/local/bin NAME=nut DESC="Network UPS Tools" CONFIG=/etc/nut/nut.conf . /lib/lsb/init-functions # set upsd specific options. use "man upsd" for more info UPSD_OPTIONS="" # set upsmon specific options. use "man upsmon" for more info UPSMON_OPTIONS="" # Include NUT nut.conf if [ -f $CONFIG ] ; then . $CONFIG fi # Explicitly require the configuration to be done in /etc/nut/nut.conf if [ "x$MODE" = "xnone" -o -z "$MODE" ] ; then log_action_msg "$NAME disabled, please adjust the configuration to your needs" log_action_msg "Then set MODE to a suitable value in $CONFIG to enable it" # exit success to avoid breaking the install process! exit 0 fi pid_dir=/var/run/nut upsmon_pid=${pid_dir}/upsmon.pid upsd_pid=${pid_dir}/upsd.pid upsd=/sbin/upsd upsdrvctl=/sbin/upsdrvctl upsmon=/sbin/upsmon log=">/dev/null 2>/dev/null" # Check if /var/run/nut exists and has the correct perms check_var_directory() { [ ! -d ${pid_dir} ] && mkdir -p ${pid_dir} \ && chown root:nut ${pid_dir} \ && chmod 770 ${pid_dir} } # check if the right components are running check_status() { case "$MODE" in standalone|netserver) status_of_proc -p $upsd_pid $upsd upsd status_of_proc -p $upsmon_pid $upsmon upsmon ;; netclient) status_of_proc -p $upsmon_pid $upsmon upsmon ;; none|*) ;; esac } start_stop_server () { case "$MODE" in standalone|netserver) case "$1" in start) ! $upsdrvctl start >/dev/null 2>&1 && \ log_progress_msg "(driver(s) failed)" || log_progress_msg "driver(s)" start-stop-daemon -S -q -p $upsd_pid -x $upsd \ -- $UPSD_OPTIONS >/dev/null 2>&1 ;; stop) start-stop-daemon -K -o -q -p $upsd_pid -n upsd >/dev/null 2>&1 ! /sbin/upsdrvctl stop >/dev/null 2>&1 && \ log_progress_msg "(driver(s) failed)" || log_progress_msg "driver(s)" ;; esac ;; none|netclient|*) return 1 ;; esac } start_stop_client () { case "$MODE" in standalone|netserver|netclient) case "$1" in start) start-stop-daemon -S -q -p $upsmon_pid -x $upsmon \ -- $UPSMON_OPTIONS >/dev/null 2>&1 ;; stop) start-stop-daemon -K -o -q -p $upsmon_pid -n upsmon >/dev/null 2>&1 ;; esac ;; none|*) return 1 ;; esac } case "$1" in start) log_daemon_msg "Starting $DESC" check_var_directory start_stop_server start && log_progress_msg "upsd" start_stop_client start && log_progress_msg "upsmon" log_end_msg 0 ;; stop) log_daemon_msg "Stopping $DESC" start_stop_server stop && log_progress_msg "upsd" start_stop_client stop && log_progress_msg "upsmon" log_end_msg 0 ;; reload) $upsd -c reload >/dev/null 2>&1 $upsmon -c reload >/dev/null 2>&1 ;; restart|force-reload) log_daemon_msg "Restarting $DESC" start_stop_client stop start_stop_server stop sleep 5 check_var_directory start_stop_server start && log_progress_msg "upsd" start_stop_client start && log_progress_msg "upsmon" log_end_msg 0 ;; status) #log_daemon_msg "Checking status of $DESC" echo "Checking status of $DESC" check_status exit $? ;; poweroff) flag=`sed -ne 's#^ *POWERDOWNFLAG *\(.*\)$#\1#p' /etc/nut/upsmon.conf` wait_delay=`sed -ne 's#^ *POWEROFF_WAIT= *\(.*\)$#\1#p' /etc/nut/nut.conf` if [ -f "$flag" ] ; then if $upsmon -K >/dev/null 2>&1 ; then log_daemon_msg "Shutting down the UPS ..." sleep 1 if $upsdrvctl shutdown ; then sleep 5 log_progress_msg "Waiting for UPS to cut the power" log_end_msg 0 else log_progress_msg "Shutdown failed." log_progress_msg "Waiting for UPS batteries to run down" log_end_msg 0 fi if [ "$wait_delay" ] ; then log_daemon_msg " (will reboot after $wait_delay) ..." sleep "$wait_delay" invoke-rc.d reboot stop fi else log_daemon_msg "Power down flag is not set (UPS shutdown not needed)" fi else if [ -z "$flag" ] ; then log_daemon_msg "##########################################################" log_progress_msg "## POWERDOWNFLAG is not defined in /etc/nut/upsmon.conf ##" log_progress_msg "## ##" log_progress_msg "## Please read the Manual page upsmon.conf(5) ##" log_progress_msg "##########################################################" log_end_msg 0 fi fi ;; *) N=/etc/init.d/$NAME echo "Usage: $N {start|stop|reload|restart|force-reload|status|poweroff}" >&2 exit 1 ;; esac exit 0