/* xppc-mib.c - subdriver to monitor XPPC SNMP devices with NUT * * Copyright (C) * 2011 - 2012 Arnaud Quette * 2014 Charles Lepple * * Note: this subdriver was initially generated as a "stub" by the * scripts/subdriver/gen-snmp-subdriver.sh script. * * This program is free software; you can redistribute it and/or modify * it under the terms of the GNU General Public License as published by * the Free Software Foundation; either version 2 of the License, or * (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * You should have received a copy of the GNU General Public License * along with this program; if not, write to the Free Software * Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA */ #include "xppc-mib.h" #define XPPC_MIB_VERSION "0.4" #define XPPC_SYSOID ".1.3.6.1.4.1.935" /* To create a value lookup structure (as needed on the 2nd line of the example * below), use the following kind of declaration, outside of the present snmp_info_t[]: * static info_lkp_t xpcc_onbatt_info[] = { * { 1, "OB", NULL, NULL }, * { 2, "OL", NULL, NULL }, * { 0, NULL, NULL, NULL } * }; */ /* upsBaseBatteryStatus */ static info_lkp_t xpcc_onbatt_info[] = { { 1, "", NULL, NULL }, /* unknown */ { 2, "", NULL, NULL }, /* batteryNormal */ { 3, "LB", NULL, NULL }, /* batteryLow */ { 0, NULL, NULL, NULL } }; /* upsBaseOutputStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), onLine(2), onBattery(3), onBoost(4), sleeping(5), onBypass(6), rebooting(7), standBy(8), onBuck(9) } */ static info_lkp_t xpcc_power_info[] = { { 1, "", NULL, NULL }, /* unknown */ { 2, "OL", NULL, NULL }, /* onLine */ { 3, "OB", NULL, NULL }, /* onBattery */ { 4, "OL BOOST", NULL, NULL }, /* onBoost */ { 5, "OFF", NULL, NULL }, /* sleeping */ { 6, "BYPASS", NULL, NULL }, /* onBypass */ { 7, "", NULL, NULL }, /* rebooting */ { 8, "OFF", NULL, NULL }, /* standBy */ { 9, "OL TRIM", NULL, NULL }, /* onBuck */ { 0, NULL, NULL, NULL } }; /* XPPC Snmp2NUT lookup table */ static snmp_info_t xppc_mib[] = { /* Data format: * { info_type, info_flags, info_len, OID, dfl, flags, oid2info, setvar }, * * info_type: NUT INFO_ or CMD_ element name * info_flags: flags to set in addinfo * info_len: length of strings if STR * cmd value if CMD, multiplier otherwise * OID: SNMP OID or NULL * dfl: default value * flags: snmp-ups internal flags (FIXME: ...) * oid2info: lookup table between OID and NUT values * * Example: * { "input.voltage", 0, 0.1, ".1.3.6.1.4.1.705.1.6.2.1.2.1", "", SU_INPUT_1, NULL }, * { "ups.status", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.705.1.7.3.0", "", SU_FLAG_OK | SU_STATUS_BATT, xpcc_onbatt_info }, * * To create a value lookup structure (as needed on the 2nd line), use the * following kind of declaration, outside of the present snmp_info_t[]: * static info_lkp_t xpcc_onbatt_info[] = { * { 1, "OB" }, * { 2, "OL" }, * { 0, NULL } * }; */ /* standard MIB items */ { "device.description", ST_FLAG_STRING | ST_FLAG_RW, SU_INFOSIZE, ".1.3.6.1.2.1.1.1.0", NULL, SU_FLAG_OK, NULL }, { "device.contact", ST_FLAG_STRING | ST_FLAG_RW, SU_INFOSIZE, ".1.3.6.1.2.1.1.4.0", NULL, SU_FLAG_OK, NULL }, { "device.location", ST_FLAG_STRING | ST_FLAG_RW, SU_INFOSIZE, ".1.3.6.1.2.1.1.6.0", NULL, SU_FLAG_OK, NULL }, { "ups.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "Tripp Lite / Phoenixtec", SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL }, /* upsBaseIdentModel.0 = STRING: "Intelligent" */ { "ups.model", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.935.1.1.1.1.1.1.0", "Generic Phoenixtec SNMP device", SU_FLAG_OK, NULL }, /* upsBaseBatteryStatus.0 = INTEGER: batteryNormal(2) */ { "ups.status", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.935.1.1.1.2.1.1.0", "", SU_STATUS_BATT | SU_TYPE_INT | SU_FLAG_OK, xpcc_onbatt_info }, /* upsSmartBatteryCapacity.0 = INTEGER: 100 */ { "battery.charge", 0, 1, ".1.3.6.1.4.1.935.1.1.1.2.2.1.0", NULL, SU_TYPE_INT | SU_FLAG_OK, NULL }, /* upsSmartBatteryTemperature.0 = INTEGER: 260 */ { "ups.temperature", 0, 0.1, ".1.3.6.1.4.1.935.1.1.1.2.2.3.0", NULL, SU_TYPE_INT | SU_FLAG_OK, NULL }, /* upsSmartInputLineVoltage.0 = INTEGER: 1998 */ { "input.voltage", 0, 0.1, ".1.3.6.1.4.1.935.1.1.1.3.2.1.0", NULL, SU_TYPE_INT | SU_FLAG_OK, NULL }, /* upsBaseOutputStatus.0 = INTEGER: onLine(2) */ { "ups.status", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.935.1.1.1.4.1.1.0", "", SU_TYPE_INT | SU_STATUS_PWR, xpcc_power_info }, /* upsSmartOutputVoltage.0 = INTEGER: 2309 */ { "output.voltage", 0, 0.1, ".1.3.6.1.4.1.935.1.1.1.4.2.1.0", NULL, SU_TYPE_INT | SU_FLAG_OK, NULL }, /* upsSmartOutputFrequency.0 = INTEGER: 500 */ { "output.frequency", 0, 0.1, ".1.3.6.1.4.1.935.1.1.1.4.2.2.0", NULL, SU_TYPE_INT | SU_FLAG_OK, NULL }, /* upsSmartOutputLoad.0 = INTEGER: 7 */ { "ups.load", 0, 1, ".1.3.6.1.4.1.935.1.1.1.4.2.3.0", NULL, SU_TYPE_INT | SU_FLAG_OK, NULL }, /* end of structure. */ { NULL, 0, 0, NULL, NULL, 0, NULL } }; mib2nut_info_t xppc = { "xppc", XPPC_MIB_VERSION, NULL, NULL, xppc_mib, XPPC_SYSOID, NULL };