'\" t .\" Title: bcmxcp .\" Author: [see the "AUTHOR" section] .\" Generator: DocBook XSL Stylesheets vsnapshot .\" Date: 04/26/2022 .\" Manual: NUT Manual .\" Source: Network UPS Tools 2.8.0 .\" Language: English .\" .TH "BCMXCP" "8" "04/26/2022" "Network UPS Tools 2\&.8\&.0" "NUT Manual" .\" ----------------------------------------------------------------- .\" * Define some portability stuff .\" ----------------------------------------------------------------- .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .\" http://bugs.debian.org/507673 .\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .ie \n(.g .ds Aq \(aq .el .ds Aq ' .\" ----------------------------------------------------------------- .\" * set default formatting .\" ----------------------------------------------------------------- .\" disable hyphenation .nh .\" disable justification (adjust text to left margin only) .ad l .\" ----------------------------------------------------------------- .\" * MAIN CONTENT STARTS HERE * .\" ----------------------------------------------------------------- .SH "NAME" bcmxcp \- Driver for UPSes supporting the serial BCM/XCP protocol .SH "NOTE" .sp This man page only documents the hardware\-specific features of the bcmxcp driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&. .SH "SUPPORTED HARDWARE" .sp This driver should recognize all serial BCM/XCP\-compatible UPSes\&. It has been developed and tested on Powerware PW5115 and PW9120 hardware\&. If your UPS has a USB connection, you may also consult the \fBbcmxcp_usb\fR(8) driver documentation\&. .SH "EXTRA ARGUMENTS" .sp This driver supports the following optional settings in the \fBups.conf\fR(5)\&. .PP \fBshutdown_delay=\fR\fIdelay\fR .RS 4 The number of seconds that the UPS should wait between receiving the shutdown command (upsdrvctl shutdown) and actually shutting off\&. .RE .PP \fBbaud_rate=\fR\fIrate\fR .RS 4 Communication speed for the UPS\&. If this is set to 9600, it tries to connect to the UPS at 9600bps\&. If it fails to communicate, it will go into baud\-hunting\&. It starts at 1200 and goes up to 19200\&. If it succeeds, it tell you the speed it connected with\&. If not included in the config, it defaults to baud\-hunting\&. .RE .SH "DEFAULT VALUES FOR THE EXTRA ARGUMENTS" .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} \fBshutdown_delay =\fR \fI120\fR .RE .sp .RS 4 .ie n \{\ \h'-04'\(bu\h'+03'\c .\} .el \{\ .sp -1 .IP \(bu 2.3 .\} \fBbaud_rate =\fR \fInone\fR .RE .SH "INSTANT COMMANDS" .sp This driver supports the following Instant Commands: .PP \fBshutdown\&.return\fR .RS 4 Turn off the load and return when power is back\&. .RE .PP \fBshutdown\&.stayoff\fR .RS 4 Turn off the load and remain off\&. .RE .PP \fBtest\&.battery\&.start\fR .RS 4 Start a battery test\&. .RE .PP \fBoutlet\&.n\&.shutdown\&.return\fR .RS 4 Turn off the load on outlet \fIn\fR and return when power is back\&. (\fIn\fR is the outlet number reported by the upsc command) .RE .SH "TODO LIST" .PP Report UPS statistics information .RS 4 BCM/XCP supports reporting of UPS statistics data\&. .RE .PP Change settings .RS 4 Access the config register to change settings\&. .RE .SH "BUGS" .sp None known\&. .SH "AUTHOR" .sp Tore Ørpetveit .SH "SEE ALSO" .SS "The core driver:" .sp \fBnutupsdrv\fR(8) .SS "The USB BCM/XCP driver:" .sp \fBbcmxcp_usb\fR(8) .SS "Internet resources:" .sp The NUT (Network UPS Tools) home page: http://www\&.networkupstools\&.org/