nut-debian/drivers/eaton-mib.c

461 lines
24 KiB
C
Raw Normal View History

2010-03-26 01:20:59 +02:00
/* eaton-mib.c - data to monitor Eaton Aphel PDUs (Basic and Complex)
*
2012-08-13 00:39:31 +03:00
* Copyright (C) 2008 - 2012
* Arnaud Quette <arnaud.quette@gmail.com>
* Arnaud Quette <ArnaudQuette@Eaton.com>
2010-03-26 01:20:59 +02:00
*
2012-08-13 00:39:31 +03:00
* Supported by Eaton <http://www.eaton.com>
* and previously MGE Office Protection Systems <http://www.mgeops.com>
2010-03-26 01:20:59 +02:00
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; either version 2 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
*
*/
#include "eaton-mib.h"
2012-01-24 12:22:33 +02:00
#define EATON_APHEL_MIB_VERSION "0.46"
2010-03-26 01:20:59 +02:00
/* APHEL-GENESIS-II-MIB (monitored ePDU)
* *************************************
* Note: we should also be able to support this one using netxml-ups!
*/
#define APHEL1_OID_MIB ".1.3.6.1.4.1.17373"
2011-09-29 21:14:46 +03:00
#define APHEL1_SYSOID APHEL1_OID_MIB
2010-03-26 01:20:59 +02:00
#define APHEL1_OID_MODEL_NAME ".1.3.6.1.4.1.17373.3.1.1.0"
#define APHEL1_OID_FIRMREV ".1.3.6.1.4.1.17373.3.1.2.0"
#define APHEL1_OID_DEVICE_NAME ".1.3.6.1.4.1.17373.3.1.3.0"
#define APHEL1_OID_UNIT_MACADDR ".1.3.6.1.4.1.17373.3.1.4.0"
/* needs concat .<outlet-index>.0 */
#define APHEL1_OID_OUTLET_CURRENT ".1.3.6.1.4.1.17373.3.2"
/* Snmp2NUT lookup table for GenesisII MIB */
static snmp_info_t eaton_aphel_genesisII_mib[] = {
/* Device page */
{ "device.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON | Powerware",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "device.model", ST_FLAG_STRING, SU_INFOSIZE, APHEL1_OID_MODEL_NAME,
"Eaton Powerware ePDU Monitored", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "device.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "pdu",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
/* UPS page */
{ "ups.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON | Powerware",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "ups.model", ST_FLAG_STRING, SU_INFOSIZE, APHEL1_OID_MODEL_NAME,
"Generic SNMP PDU", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.id", ST_FLAG_STRING, SU_INFOSIZE, APHEL1_OID_DEVICE_NAME,
"unknown", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.firmware", ST_FLAG_STRING, SU_INFOSIZE, APHEL1_OID_FIRMREV, "",
SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "pdu",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "ups.macaddr", ST_FLAG_STRING, SU_INFOSIZE, APHEL1_OID_UNIT_MACADDR, "unknown",
0, NULL, NULL },
/* Outlet page */
/* we can't use template since there is no counterpart to outlet.count */
2012-01-24 12:22:33 +02:00
{ "outlet.1.current", 0, 0.1, APHEL1_OID_OUTLET_CURRENT ".1.0", NULL, SU_FLAG_NEGINVALID, NULL, NULL },
{ "outlet.2.current", 0, 0.1, APHEL1_OID_OUTLET_CURRENT ".2.0", NULL, SU_FLAG_NEGINVALID, NULL, NULL },
{ "outlet.3.current", 0, 0.1, APHEL1_OID_OUTLET_CURRENT ".3.0", NULL, SU_FLAG_NEGINVALID, NULL, NULL },
{ "outlet.4.current", 0, 0.1, APHEL1_OID_OUTLET_CURRENT ".4.0", NULL, SU_FLAG_NEGINVALID, NULL, NULL },
{ "outlet.5.current", 0, 0.1, APHEL1_OID_OUTLET_CURRENT ".5.0", NULL, SU_FLAG_NEGINVALID, NULL, NULL },
{ "outlet.6.current", 0, 0.1, APHEL1_OID_OUTLET_CURRENT ".6.0", NULL, SU_FLAG_NEGINVALID, NULL, NULL },
{ "outlet.7.current", 0, 0.1, APHEL1_OID_OUTLET_CURRENT ".7.0", NULL, SU_FLAG_NEGINVALID, NULL, NULL },
{ "outlet.8.current", 0, 0.1, APHEL1_OID_OUTLET_CURRENT ".8.0", NULL, SU_FLAG_NEGINVALID, NULL, NULL },
2010-03-26 01:20:59 +02:00
/* end of structure. */
{ NULL, 0, 0, NULL, NULL, 0, NULL, NULL }
};
/* APHEL PDU-MIB - Revelation MIB (Managed ePDU)
* ********************************************* */
2011-09-29 21:14:46 +03:00
#define AR_BASE_OID ".1.3.6.1.4.1.534.6.6.6"
#define APHEL2_SYSOID AR_BASE_OID
#define APHEL2_OID_MODEL_NAME AR_OID_MODEL_NAME
2010-03-26 01:20:59 +02:00
#define AR_OID_MODEL_NAME AR_BASE_OID ".1.1.12.0"
#define AR_OID_DEVICE_NAME AR_BASE_OID ".1.1.13.0"
#define AR_OID_FIRMREV AR_BASE_OID ".1.1.1.0"
#define AR_OID_SERIAL AR_BASE_OID ".1.1.2.0"
#define AR_OID_UNIT_MACADDR AR_BASE_OID ".1.1.6.0"
#define AR_OID_UNIT_CURRENT AR_BASE_OID ".1.3.1.1"
#define AR_OID_UNIT_VOLTAGE AR_BASE_OID ".1.3.1.2"
#define AR_OID_UNIT_ACTIVEPOWER AR_BASE_OID ".1.3.1.3"
#define AR_OID_UNIT_APPARENTPOWER AR_BASE_OID ".1.3.1.4"
#define AR_OID_UNIT_CPUTEMPERATURE AR_BASE_OID ".1.3.1.5.0"
#define AR_OID_OUTLET_INDEX AR_BASE_OID ".1.2.2.1.1"
#define AR_OID_OUTLET_NAME AR_BASE_OID ".1.2.2.1.2"
#define AR_OID_OUTLET_STATUS AR_BASE_OID ".1.2.2.1.3"
static info_lkp_t outlet_status_info[] = {
{ -1, "error" },
{ 0, "off" },
{ 1, "on" },
{ 2, "cycling" }, /* transitional status */
{ 0, NULL }
};
#define DO_OFF 0
#define DO_ON 1
#define DO_CYCLE 2
#define AR_OID_OUTLET_COUNT AR_BASE_OID ".1.2.1.0"
#define AR_OID_OUTLET_CURRENT AR_BASE_OID ".1.2.2.1.4"
#define AR_OID_OUTLET_MAXCURRENT AR_BASE_OID ".1.2.2.1.5"
#define AR_OID_OUTLET_VOLTAGE AR_BASE_OID ".1.2.2.1.6"
#define AR_OID_OUTLET_ACTIVEPOWER AR_BASE_OID ".1.2.2.1.7"
#define AR_OID_OUTLET_APPARENTPOWER AR_BASE_OID ".1.2.2.1.8"
#define AR_OID_OUTLET_POWERFACTOR AR_BASE_OID ".1.2.2.1.9"
/* Snmp2NUT lookup table for Eaton Revelation MIB */
static snmp_info_t eaton_aphel_revelation_mib[] = {
/* Device page */
{ "device.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON | Powerware",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "device.model", ST_FLAG_STRING, SU_INFOSIZE, AR_OID_MODEL_NAME,
"Eaton Powerware ePDU Managed", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "device.serial", ST_FLAG_STRING, SU_INFOSIZE, AR_OID_SERIAL, "",
SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "device.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "pdu",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
/* UPS page */
{ "ups.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON | Powerware",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "ups.model", ST_FLAG_STRING, SU_INFOSIZE, AR_OID_MODEL_NAME,
"Generic SNMP PDU", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.id", ST_FLAG_STRING, SU_INFOSIZE, AR_OID_DEVICE_NAME,
"unknown", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.serial", ST_FLAG_STRING, SU_INFOSIZE, AR_OID_SERIAL, "",
SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.firmware", ST_FLAG_STRING, SU_INFOSIZE, AR_OID_FIRMREV, "",
SU_FLAG_STATIC | SU_FLAG_OK, NULL },
{ "ups.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "pdu",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "ups.macaddr", ST_FLAG_STRING, SU_INFOSIZE, AR_OID_UNIT_MACADDR, "",
SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.temperature", 0, 1, AR_OID_UNIT_CPUTEMPERATURE, NULL, 0, NULL, NULL },
/* Outlet page */
{ "outlet.id", 0, 1, NULL, "0", SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "outlet.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, NULL, "All outlets",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "outlet.count", 0, 1, AR_OID_OUTLET_COUNT, "0", 0, NULL },
{ "outlet.current", 0, 0.001, AR_OID_UNIT_CURRENT ".0", NULL, 0, NULL, NULL },
{ "outlet.voltage", 0, 0.001, AR_OID_UNIT_VOLTAGE ".0", NULL, 0, NULL, NULL },
{ "outlet.realpower", 0, 1.0, AR_OID_UNIT_ACTIVEPOWER ".0", NULL, 0, NULL, NULL },
{ "outlet.power", 0, 1.0, AR_OID_UNIT_APPARENTPOWER ".0", NULL, 0, NULL, NULL },
/* outlet template definition
* Caution: the index of the data start at 0, while the name is +1
* ie outlet.1 => <OID>.0 */
{ "outlet.%i.switchable", 0, 1, AR_OID_OUTLET_INDEX ".%i", "yes", SU_FLAG_STATIC | SU_OUTLET, NULL, NULL },
{ "outlet.%i.id", 0, 1, NULL, "%i", SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK | SU_OUTLET, NULL, NULL },
{ "outlet.%i.desc", ST_FLAG_RW | ST_FLAG_STRING, SU_INFOSIZE, AR_OID_OUTLET_NAME ".%i", NULL, SU_OUTLET, NULL, NULL },
{ "outlet.%i.status", ST_FLAG_STRING, SU_INFOSIZE, AR_OID_OUTLET_STATUS ".%i", NULL, SU_FLAG_OK | SU_OUTLET, &outlet_status_info[0], NULL },
{ "outlet.%i.current", 0, 0.001, AR_OID_OUTLET_CURRENT ".%i", NULL, SU_OUTLET, NULL, NULL },
{ "outlet.%i.current.maximum", 0, 0.001, AR_OID_OUTLET_MAXCURRENT ".%i", NULL, SU_OUTLET, NULL, NULL },
{ "outlet.%i.realpower", 0, 1.0, AR_OID_OUTLET_ACTIVEPOWER ".%i", NULL, SU_OUTLET, NULL, NULL },
{ "outlet.%i.voltage", 0, 1.0, AR_OID_OUTLET_VOLTAGE ".%i", NULL, SU_OUTLET, NULL, NULL },
{ "outlet.%i.powerfactor", 0, 0.01, AR_OID_OUTLET_POWERFACTOR ".%i", NULL, SU_OUTLET, NULL, NULL },
{ "outlet.%i.power", 0, 1.0, AR_OID_OUTLET_APPARENTPOWER ".%i", NULL, SU_OUTLET, NULL, NULL },
/* FIXME:
* - delay for startup/shutdown sequence
2011-06-01 23:31:49 +03:00
* - support for multiple Ambient sensors ( max. 8), starting at index '0'
* ambient.%i.temperature => .1.3.6.1.4.1.534.6.6.6.2.2.1.3.%i
* ambient.%i.humidity => .1.3.6.1.4.1.534.6.6.6.2.4.1.3.%i
2010-03-26 01:20:59 +02:00
*/
2011-06-01 23:31:49 +03:00
/* Ambient page */
/* We use critical levels, for both temperature and humidity,
* since warning levels are also available! */
{ "ambient.temperature", 0, 1.0, ".1.3.6.1.4.1.534.6.6.6.2.2.1.3.0", NULL, SU_FLAG_OK, NULL, NULL },
{ "ambient.temperature.low", 0, 1.0, "1.3.6.1.4.1.534.6.6.6.2.2.1.6.0", NULL, SU_FLAG_OK, NULL, NULL },
{ "ambient.temperature.high", 0, 1.0, "1.3.6.1.4.1.534.6.6.6.2.2.1.7.0", NULL, SU_FLAG_OK, NULL, NULL },
{ "ambient.humidity", 0, 1.0, ".1.3.6.1.4.1.534.6.6.6.2.4.1.3.0", NULL, SU_FLAG_OK, NULL, NULL },
{ "ambient.humidity.low", 0, 1.0, ".1.3.6.1.4.1.534.6.6.6.2.4.1.6.0", NULL, SU_FLAG_OK, NULL, NULL },
{ "ambient.humidity.high", 0, 1.0, ".1.3.6.1.4.1.534.6.6.6.2.4.1.7.0", NULL, SU_FLAG_OK, NULL, NULL },
2010-03-26 01:20:59 +02:00
/* instant commands. */
/* Note that load.cycle might be replaced by / mapped on shutdown.reboot */
/* no counterpart found!
{ "outlet.load.off", 0, DO_OFF, AR_OID_OUTLET_STATUS ".0", NULL, SU_TYPE_CMD, NULL, NULL },
{ "outlet.load.on", 0, DO_ON, AR_OID_OUTLET_STATUS ".0", NULL, SU_TYPE_CMD, NULL, NULL },
{ "outlet.load.cycle", 0, DO_CYCLE, AR_OID_OUTLET_STATUS ".0", NULL, SU_TYPE_CMD, NULL, NULL }, */
{ "outlet.%i.load.off", 0, DO_OFF, AR_OID_OUTLET_STATUS ".%i", NULL, SU_TYPE_CMD | SU_OUTLET, NULL, NULL },
{ "outlet.%i.load.on", 0, DO_ON, AR_OID_OUTLET_STATUS ".%i", NULL, SU_TYPE_CMD | SU_OUTLET, NULL, NULL },
{ "outlet.%i.load.cycle", 0, DO_CYCLE, AR_OID_OUTLET_STATUS ".%i", NULL, SU_TYPE_CMD | SU_OUTLET, NULL, NULL },
/* end of structure. */
{ NULL, 0, 0, NULL, NULL, 0, NULL, NULL }
};
2011-09-29 21:14:46 +03:00
/* Eaton PDU-MIB - Marlin MIB
* ************************** */
2012-01-24 12:22:33 +02:00
#define EATON_MARLIN_MIB_VERSION "0.06"
2011-09-29 21:14:46 +03:00
#define EATON_MARLIN_SYSOID ".1.3.6.1.4.1.534.6.6.7"
#define EATON_MARLIN_OID_MODEL_NAME ".1.3.6.1.4.1.534.6.6.7.1.2.1.2.0"
static info_lkp_t marlin_outlet_status_info[] = {
{ 0, "off" },
{ 1, "on" },
{ 2, "pendingOff" }, /* transitional status */
{ 3, "pendingOn" }, /* transitional status */
{ 0, NULL }
};
2012-01-24 12:22:33 +02:00
/* Ugly hack: having the matching OID present means that the outlet is
* switchable. So, it should not require this value lookup */
static info_lkp_t outlet_switchability_info[] = {
{ -1, "yes" },
{ 0, "yes" },
{ 0, NULL }
};
2011-09-29 21:14:46 +03:00
/* Snmp2NUT lookup table for Eaton Marlin MIB */
static snmp_info_t eaton_marlin_mib[] = {
/* Device page */
{ "device.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "device.model", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.534.6.6.7.1.2.1.2.0",
"Eaton Powerware ePDU", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "device.serial", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.534.6.6.7.1.2.1.4.0",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "device.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "pdu",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
/* FIXME: need RFC validation on this variable
* { "device.part", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.534.6.6.7.1.2.1.3.0",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL }, */
/* UPS page */
{ "ups.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "ups.model", ST_FLAG_STRING, SU_INFOSIZE, "1.3.6.1.4.1.534.6.6.7.1.2.1.2.0",
"Eaton Powerware ePDU", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
/* FIXME: use unitName.0 (ePDU)?
* { "ups.id", ST_FLAG_STRING, SU_INFOSIZE, AR_OID_DEVICE_NAME,
"unknown", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL }, */
{ "ups.serial", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.534.6.6.7.1.2.1.4.0",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.firmware", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.534.6.6.7.1.2.1.5.0",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL },
{ "ups.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "pdu",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
/* TODO:
* The below possibly requires (?) the use of
* int snprint_hexstring(char *buf, size_t buf_len, const u_char *, size_t);
* { "ups.macaddr", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.2.1.2.2.1.6.2",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
* + date reformating callback
* 2011-8-29,16:27:25.0,+1:0
* Hex-STRING: 07 DB 08 1D 10 0C 36 00 2B 01 00 00
* { "ups.date", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.534.6.6.7.1.2.1.8.0",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
* { "ups.time", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.534.6.6.7.1.2.1.8.0",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
*/
/* Input page */
{ "input.phases", 0, 1, ".1.3.6.1.4.1.534.6.6.7.1.2.1.20.0", NULL, SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
/* inputType.0.1 singlePhase (1) iso.3.6.1.4.1.534.6.6.7.3.1.1.2.0.1 */
{ "input.frequency", 0, 0.1, ".1.3.6.1.4.1.534.6.6.7.3.1.1.3.0.1", NULL, 0, NULL, NULL },
{ "input.voltage", 0, 0.001, ".1.3.6.1.4.1.534.6.6.7.3.2.1.3.0.1.1", NULL, 0, NULL, NULL },
/* FIXME: check multiplier */
{ "input.current", 0, 0.01, ".1.3.6.1.4.1.534.6.6.7.3.3.1.4.0.1.1", NULL, 0, NULL, NULL },
/* Ambient page */
/* We use critical levels, for both temperature and humidity,
* since warning levels are also available! */
{ "ambient.temperature", 0, 0.1, ".1.3.6.1.4.1.534.6.6.7.7.1.1.4.0.1", NULL, SU_FLAG_OK, NULL, NULL },
{ "ambient.temperature.low", 0, 0.1, ".1.3.6.1.4.1.534.6.6.7.7.1.1.7.0.1", NULL, SU_FLAG_NEGINVALID | SU_FLAG_OK, NULL, NULL },
{ "ambient.temperature.high", 0, 0.1, ".1.3.6.1.4.1.534.6.6.7.7.1.1.9.0.1", NULL, SU_FLAG_NEGINVALID | SU_FLAG_OK, NULL, NULL },
{ "ambient.humidity", 0, 0.1, ".1.3.6.1.4.1.534.6.6.7.7.2.1.4.0.1", NULL, SU_FLAG_OK, NULL, NULL },
{ "ambient.humidity.low", 0, 0.1, ".1.3.6.1.4.1.534.6.6.7.7.2.1.7.0.1", NULL, SU_FLAG_NEGINVALID | SU_FLAG_OK, NULL, NULL },
{ "ambient.humidity.high", 0, 0.1, ".1.3.6.1.4.1.534.6.6.7.7.2.1.9.0.1", NULL, SU_FLAG_NEGINVALID | SU_FLAG_OK, NULL, NULL },
/* Outlet page */
{ "outlet.id", 0, 1, NULL, "0", SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "outlet.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, NULL, "All outlets",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "outlet.count", 0, 1, ".1.3.6.1.4.1.534.6.6.7.1.2.1.22.0", "0", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
/* The below ones are the same as the input.* equivalent */
{ "outlet.frequency", 0, 0.1, ".1.3.6.1.4.1.534.6.6.7.3.1.1.3.0.1", NULL, 0, NULL, NULL },
{ "outlet.voltage", 0, 0.001, ".1.3.6.1.4.1.534.6.6.7.3.2.1.3.0.1.1", NULL, 0, NULL, NULL },
{ "outlet.current", 0, 0.01, ".1.3.6.1.4.1.534.6.6.7.3.3.1.4.0.1.1", NULL, 0, NULL, NULL },
/* There is also a .2 available (ie .1.3.6.1.4.1.534.6.6.7.3.4.1.3.0.1.2) */
{ "outlet.realpower", 0, 1.0, ".1.3.6.1.4.1.534.6.6.7.3.4.1.4.0.1.2", NULL, 0, NULL, NULL },
/* There is also a .2 available (ie .1.3.6.1.4.1.534.6.6.7.3.4.1.3.0.1.2) */
{ "outlet.power", 0, 1.0, ".1.3.6.1.4.1.534.6.6.7.3.4.1.3.0.1.1", NULL, 0, NULL, NULL },
/* outlet template definition
* Indexes start from 1, ie outlet.1 => <OID>.1 */
/* Note: the first definition is used to determine the base index (ie 0 or 1) */
{ "outlet.%i.desc", ST_FLAG_RW | ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.534.6.6.7.6.1.1.3.0.%i", NULL, SU_FLAG_STATIC | SU_FLAG_OK | SU_OUTLET, NULL, NULL },
{ "outlet.%i.status", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.534.6.6.7.6.6.1.2.0.%i",
NULL, SU_FLAG_OK | SU_OUTLET, &marlin_outlet_status_info[0], NULL },
/* FIXME: or use ".1.3.6.1.4.1.534.6.6.7.6.1.1.2.0.1", though it's related to groups! */
{ "outlet.%i.id", 0, 1, NULL, "%i", SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK | SU_OUTLET, NULL, NULL },
{ "outlet.%i.current", 0, 0.001, ".1.3.6.1.4.1.534.6.6.7.6.4.1.3.0.%i", NULL, SU_OUTLET, NULL, NULL },
{ "outlet.%i.realpower", 0, 1.0, ".1.3.6.1.4.1.534.6.6.7.6.5.1.3.0.%i", NULL, SU_OUTLET, NULL, NULL },
{ "outlet.%i.voltage", 0, 0.001, ".1.3.6.1.4.1.534.6.6.7.6.3.1.2.0.%i", NULL, SU_OUTLET, NULL, NULL },
{ "outlet.%i.power", 0, 1.0, ".1.3.6.1.4.1.534.6.6.7.6.5.1.2.0.%i", NULL, SU_OUTLET, NULL, NULL },
2012-01-24 12:22:33 +02:00
/* FIXME: handle non switchable units (only measurements), which do not expose this OID */
{ "outlet.%i.switchable", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.534.6.6.7.6.6.1.3.0.%i", "no", SU_FLAG_STATIC | SU_FLAG_OK, &outlet_switchability_info[0], NULL },
2011-09-29 21:14:46 +03:00
/* TODO: handle statistics
* outletWh.0.1
* outletWhTimer.0.1
*/
/* instant commands. */
/* Notes:
* - load.cycle might be replaced by / mapped on shutdown.reboot
* - outletControl{Off,On,Reboot}Cmd values:
* 0-n : Timer
* -1 : Cancel
* we currently use "0", so instant On | Off | Reboot... */
/* no counterpart found!
{ "outlet.load.off", 0, DO_OFF, AR_OID_OUTLET_STATUS ".0", NULL, SU_TYPE_CMD, NULL, NULL },
{ "outlet.load.on", 0, DO_ON, AR_OID_OUTLET_STATUS ".0", NULL, SU_TYPE_CMD, NULL, NULL },
{ "outlet.load.cycle", 0, DO_CYCLE, AR_OID_OUTLET_STATUS ".0", NULL, SU_TYPE_CMD, NULL, NULL }, */
/* TODO: handle delays */
{ "outlet.%i.load.off", 0, 0, ".1.3.6.1.4.1.534.6.6.7.6.6.1.3.0.%i", NULL, SU_TYPE_CMD | SU_OUTLET, NULL, NULL },
{ "outlet.%i.load.on", 0, 0, ".1.3.6.1.4.1.534.6.6.7.6.6.1.4.0.%i", NULL, SU_TYPE_CMD | SU_OUTLET, NULL, NULL },
{ "outlet.%i.load.cycle", 0, 0, ".1.3.6.1.4.1.534.6.6.7.6.6.1.5.0.%i", NULL, SU_TYPE_CMD | SU_OUTLET, NULL, NULL },
/* end of structure. */
{ NULL, 0, 0, NULL, NULL, 0, NULL, NULL }
};
2012-08-13 00:39:31 +03:00
/* Pulizzi Monitored ePDU (Basic model, SNMP only)
* FIXME: to be completed
*
* Warning: there are 2 versions:
* - SA built MI.mib (old MIB)
* #define PULIZZI1_OID_MIB ".1.3.6.1.4.1.20677.3.1.1"
* #define PULIZZI1_OID_MODEL_NAME ".1.3.6.1.4.1.20677.3.1.1.1.2.0"
* - Eaton-Powerware-Monitored-ePDU_1.0.E.mib (new MIB) Vertical SW
*/
/* Pulizzi Switched ePDU */
#define EATON_PULIZZI_SW_MIB_VERSION "0.1"
#define PULIZZI_SW_OID_MIB ".1.3.6.1.4.1.20677.3.1.1"
#define PULIZZI_SW_OID_MODEL_NAME ".1.3.6.1.4.1.20677.2.1.1.0"
/* Some buggy FW also report sysOID = ".1.3.6.1.4.1.20677.1" */
#define EATON_PULIZZI_SWITCHED1_SYSOID ".1.3.6.1.4.1.20677.1"
#define EATON_PULIZZI_SWITCHED2_SYSOID ".1.3.6.1.4.1.20677.2"
static info_lkp_t pulizzi_sw_outlet_status_info[] = {
{ 1, "on" },
{ 2, "off" },
{ 0, NULL }
};
/* simply remap the above status to "yes" */
static info_lkp_t pulizzi_sw_outlet_switchability_info[] = {
{ 1, "yes" },
{ 2, "yes" },
{ 0, NULL }
};
/* Snmp2NUT lookup table for Eaton Pulizzi Switched ePDU MIB */
static snmp_info_t eaton_pulizzi_switched_mib[] = {
/* Device page */
{ "device.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON | Powerware",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "device.model", ST_FLAG_STRING, SU_INFOSIZE, PULIZZI_SW_OID_MODEL_NAME,
"Switched ePDU", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "device.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "pdu",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
/* UPS page */
{ "ups.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "EATON",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL, NULL },
{ "ups.model", ST_FLAG_STRING, SU_INFOSIZE, PULIZZI_SW_OID_MODEL_NAME,
"Switched ePDU", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
/* FIXME: to be moved to the device collection! */
{ "ups.date", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.1.4.0",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.time", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.1.3.0",
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL, NULL },
{ "ups.macaddr", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.2.6.0",
"unknown", 0, NULL, NULL },
/* Outlet page */
/* Note: outlet.count is deduced, with guestimate_outlet_count() */
{ "outlet.id", 0, 1, NULL, "0", SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "outlet.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, NULL, "All outlets",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "outlet.current", 0, 1.0, ".1.3.6.1.4.1.20677.2.8.6.4.2.0", NULL, 0, NULL, NULL },
{ "outlet.voltage", 0, 1.0, ".1.3.6.1.4.1.20677.2.8.6.4.1.0", NULL, 0, NULL, NULL },
{ "outlet.power", 0, 1.0, ".1.3.6.1.4.1.20677.2.8.6.4.3.0", NULL, 0, NULL, NULL },
/* outlet template definition
* Notes:
* - indexes start from 1, ie outlet.1 => <OID>.1
* - the first definition is used to determine the base index (ie 0 or 1)
* - outlet.count is estimated, based on the below OID iteration capabilities */
{ "outlet.%i.desc", ST_FLAG_RW | ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.6.1.%i.1.0", NULL, SU_FLAG_STATIC | SU_FLAG_OK | SU_OUTLET, NULL, NULL },
{ "outlet.%i.status", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.6.3.%i.0",
NULL, SU_FLAG_OK | SU_OUTLET, &pulizzi_sw_outlet_status_info[0], NULL },
{ "outlet.%i.id", 0, 1, NULL, "%i", SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK | SU_OUTLET, NULL, NULL },
/* we use the same OID as outlet.n.status..., to expose switchability */
{ "outlet.%i.switchable", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.6.3.%i.0", "yes", SU_FLAG_STATIC | SU_FLAG_OK | SU_OUTLET, &pulizzi_sw_outlet_switchability_info[0], NULL },
/* FIXME: need to be added to the namespace! */
{ "outlet.%i.delay.reboot", ST_FLAG_RW, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.6.1.%i.5.0", NULL, SU_OUTLET, NULL, NULL },
/* "outlet1SequenceTime" is used for global sequence */
{ "outlet.%i.delay.start", ST_FLAG_RW, SU_INFOSIZE, ".1.3.6.1.4.1.20677.2.6.1.%i.4.0", NULL, SU_OUTLET, NULL, NULL },
/* instant commands. */
/* FIXME: not exposed as "outlet.load...", or otherwise specific processing applies (template instanciation) */
{ "load.on", 0, 1, ".1.3.6.1.4.1.20677.2.6.2.1.0", NULL, SU_TYPE_CMD, NULL, NULL },
{ "load.off", 0, 2, ".1.3.6.1.4.1.20677.2.6.2.1.0", NULL, SU_TYPE_CMD, NULL, NULL },
{ "load.on.delay", 0, 3, ".1.3.6.1.4.1.20677.2.6.2.1.0", NULL, SU_TYPE_CMD, NULL, NULL },
{ "load.off.delay", 0, 4, ".1.3.6.1.4.1.20677.2.6.2.1.0", NULL, SU_TYPE_CMD, NULL, NULL },
/* WARNING: outlet 1 => index 2! */
{ "outlet.%i.load.on", 0, 1, ".1.3.6.1.4.1.20677.2.6.2.%i.0", NULL, SU_TYPE_CMD | SU_OUTLET | SU_CMD_OFFSET, NULL, NULL },
{ "outlet.%i.load.off", 0, 2, ".1.3.6.1.4.1.20677.2.6.2.%i.0", NULL, SU_TYPE_CMD | SU_OUTLET | SU_CMD_OFFSET, NULL, NULL },
{ "outlet.%i.load.cycle", 0, 3, ".1.3.6.1.4.1.20677.2.6.2.%i.0", NULL, SU_TYPE_CMD | SU_OUTLET | SU_CMD_OFFSET, NULL, NULL },
/* end of structure. */
{ NULL, 0, 0, NULL, NULL, 0, NULL, NULL }
};
2011-09-29 21:14:46 +03:00
mib2nut_info_t aphel_genesisII = { "aphel_genesisII", EATON_APHEL_MIB_VERSION, "", APHEL1_OID_MODEL_NAME, eaton_aphel_genesisII_mib, APHEL1_SYSOID };
mib2nut_info_t aphel_revelation = { "aphel_revelation", EATON_APHEL_MIB_VERSION, "", APHEL2_OID_MODEL_NAME, eaton_aphel_revelation_mib, APHEL2_SYSOID };
mib2nut_info_t eaton_marlin = { "eaton_epdu", EATON_MARLIN_MIB_VERSION, "", EATON_MARLIN_OID_MODEL_NAME, eaton_marlin_mib, EATON_MARLIN_SYSOID };
2012-08-13 00:39:31 +03:00
/*mib2nut_info_t pulizzi_monitored = { "pulizzi_monitored", EATON_PULIZZI_MIB_VERSION, "", PULIZZI1_OID_MODEL_NAME, eaton_pulizzi_monitored_mib, PULIZZI1_OID_MIB };*/
mib2nut_info_t pulizzi_switched1 = { "pulizzi_switched1", EATON_PULIZZI_SW_MIB_VERSION, "", EATON_PULIZZI_SWITCHED1_SYSOID, eaton_pulizzi_switched_mib, EATON_PULIZZI_SWITCHED1_SYSOID };
mib2nut_info_t pulizzi_switched2 = { "pulizzi_switched2", EATON_PULIZZI_SW_MIB_VERSION, "", EATON_PULIZZI_SWITCHED1_SYSOID, eaton_pulizzi_switched_mib, EATON_PULIZZI_SWITCHED2_SYSOID };