nut-debian/docs/man/snmp-ups.8

211 lines
6.4 KiB
Groff
Raw Normal View History

2011-01-26 11:35:08 +02:00
'\" t
.\" Title: snmp-ups
.\" Author: [see the "AUTHORS" section]
.\" Generator: DocBook XSL Stylesheets v1.75.2 <http://docbook.sf.net/>
2012-08-13 00:39:31 +03:00
.\" Date: 08/07/2012
2011-01-26 11:35:08 +02:00
.\" Manual: NUT Manual
.\" Source: Network UPS Tools
.\" Language: English
.\"
2012-08-13 00:39:31 +03:00
.TH "SNMP\-UPS" "8" "08/07/2012" "Network UPS Tools" "NUT Manual"
2011-01-26 11:35:08 +02:00
.\" -----------------------------------------------------------------
.\" * Define some portability stuff
.\" -----------------------------------------------------------------
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.\" http://bugs.debian.org/507673
.\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html
.\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
.ie \n(.g .ds Aq \(aq
.el .ds Aq '
.\" -----------------------------------------------------------------
.\" * set default formatting
.\" -----------------------------------------------------------------
.\" disable hyphenation
.nh
.\" disable justification (adjust text to left margin only)
.ad l
.\" -----------------------------------------------------------------
.\" * MAIN CONTENT STARTS HERE *
.\" -----------------------------------------------------------------
.SH "NAME"
snmp-ups \- Multi\-MIB Driver for SNMP UPS equipment
.SH "NOTE"
.sp
This man page only documents the hardware\-specific features of the snmp\-ups driver\&. For information about the core driver, see \fBnutupsdrv\fR(8)\&.
.SH "SUPPORTED HARDWARE"
.sp
The snmp\-ups driver automatically detects and supports a wide range of devices by loading various MIBS: \fBietf\fR:: UPS that is RFC 1628 (UPS MIB) compliant, e\&.g\&. MGE UPS SYSTEMS, Liebert, perhaps others (default)
.PP
\fBmge\fR
.RS 4
MGE UPS SYSTEMS and MGE Office Protection Systems devices with SNMP cards (ref 66062, 66045, 66074 and 66244)
.RE
.PP
\fBapcc\fR
.RS 4
2012-06-01 16:55:19 +03:00
APC AP9605, AP9606, AP9617, and AP9618 APC network management cards, as well as any others supporting the APC POWERNET MIB
2011-01-26 11:35:08 +02:00
.RE
.PP
\fBnetvision\fR
.RS 4
Socomec Sicon UPS with Netvision Web/SNMP management card/external box
.RE
.PP
\fBpw\fR
.RS 4
Powerware devices with ConnectUPS SNMP cards
.RE
.PP
\fBaphel_genesisII\fR
.RS 4
Eaton Powerware ePDU Monitored
.RE
.PP
\fBaphel_revelation\fR
.RS 4
Eaton Powerware ePDU Managed
.RE
.PP
\fBraritan\fR
.RS 4
Various Raritan PDUs
.RE
.PP
\fBbaytech\fR
.RS 4
Various BayTech PDUs
.RE
.PP
\fBcpqpower\fR
.RS 4
HP/Compaq AF401A management card, perhaps others
.RE
2012-01-24 12:22:33 +02:00
.PP
\fBcyberpower\fR
.RS 4
Cyberpower RMCARD201\&. Should also support RMCARD100 (net version), RMCARD202 and RMCARD301
.RE
2011-01-26 11:35:08 +02:00
.SH "EXTRA ARGUMENTS"
.sp
This driver supports the following optional settings in the \fBups.conf\fR(5):
.PP
\fBmibs\fR=\fIname\fR
.RS 4
Set MIB compliance (default=auto, allowed entries: refer to the above SUPPORTED HARDWARE)\&. With "auto", the driver will try a select set of SNMP objects until it finds one that the device responds to\&.
.RE
.PP
\fBcommunity\fR=\fIname\fR
.RS 4
Set community name (default = public)\&. Note that you require a RW community name to change UPS settings (as for a powerdown)\&.
.RE
.PP
\fBsnmp_version\fR=\fIversion\fR
.RS 4
Set SNMP version (default = v1, the other allowed value is v2c)
.RE
.PP
\fBpollfreq\fR=\fIvalue\fR
.RS 4
Set polling frequency in seconds, to reduce network flow (default=30)
.RE
.PP
\fBnotransferoids\fR
.RS 4
Disable the monitoring of the low and high voltage transfer OIDs in the hardware\&. This will remove input\&.transfer\&.low and input\&.transfer\&.high from the list of variables\&. This should only be used on APCC Symmetra equipment which has strangeness in the three\-phase power reporting\&.
.RE
.PP
\fBsecLevel\fR=\fIvalue\fR
.RS 4
Set the securityLevel used for SNMPv3 messages (default=noAuthNoPriv, allowed: authNoPriv,authPriv)
.RE
.PP
\fBsecName\fR=\fIvalue\fR
.RS 4
Set the securityName used for authenticated SNMPv3 messages (no default)
.RE
.PP
\fBauthPassword\fR=\fIvalue\fR
.RS 4
Set the authentication pass phrase used for authenticated SNMPv3 messages (no default)
.RE
.PP
\fBprivPassword\fR=\fIvalue\fR
.RS 4
Set the privacy pass phrase used for encrypted SNMPv3 messages (no default)
.RE
.PP
\fBauthProtocol\fR=\fIvalue\fR
.RS 4
Set the authentication protocol (MD5 or SHA) used for authenticated SNMPv3 messages (default=MD5)
.RE
.PP
\fBprivProtocol\fR=\fIvalue\fR
.RS 4
Set the privacy protocol (DES or AES) used for encrypted SNMPv3 messages (default=DES)
.RE
.SH "REQUIREMENTS"
.sp
You will need to install the Net\-SNMP package from http://www\&.net\-snmp\&.org/ before building this driver\&.
.sp
SNMP v3 also requires OpenSSL support from http://www\&.openssl\&.org\&.
.SH "LIMITATION"
.SS "Shutdown"
.sp
This driver does not provide a proper upsdrv_shutdown() function\&. There probably never will be one, since at the time this script should run (near the end of the system halt script), there will be no network capabilities anymore\&. Probably the only way to shutdown an SNMP UPS is by sending it a shutdown with delay command through \fBupscmd\fR(8) and hope for the best that the system will have finished shutting down before the power is cut\&.
.SH "INSTALLATION"
.sp
This driver is only built if the Net\-SNMP development files are present on the system\&. You can also force it to be built by using "configure \-\-with\-snmp=yes" before calling make\&.
.SH "IMPLEMENTATION"
.sp
The hostname of the UPS is specified with the "port" value in ups\&.conf, i\&.e\&.:
.sp
.if n \{\
.RS 4
.\}
.nf
[snmpv1]
driver = snmp\-ups
port = snmp\-ups\&.example\&.com
community = public
snmp_version = v1
mibs = ietf
pollfreq = 15
desc = "Example SNMP v1 device"
.fi
.if n \{\
.RE
.\}
.sp
.if n \{\
.RS 4
.\}
.nf
[snmpv3]
driver = snmp\-ups
port = 166\&.99\&.224\&.132
mibs = mge
secLevel = authPriv
secName = mysecurityname
authPassword = myauthenticationpassphrase
privPassword = myprivatepassphrase
desc = "Example SNMP v3 device, with the highest security level"
.fi
.if n \{\
.RE
.\}
.SH "AUTHORS"
.sp
Arnaud Quette, Dmitry Frolov
.sp
Sponsored by Eaton http://www\&.eaton\&.com and originally by MGE UPS SYSTEMS http://www\&.mgeups\&.com/
.SH "SEE ALSO"
.SS "The core driver:"
.sp
\fBnutupsdrv\fR(8)
.SS "NUT SNMP Protocols Library"
.sp
Available at: http://www\&.networkupstools\&.org/protocols/snmp/
.SS "Internet resources:"
.sp
The NUT (Network UPS Tools) home page: http://www\&.networkupstools\&.org/