nut-debian/docs/man/upscmd.txt

114 lines
3.2 KiB
Plaintext
Raw Normal View History

2011-01-26 11:35:08 +02:00
UPSCMD(8)
=========
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
NAME
----
2022-07-10 10:23:45 +03:00
2011-01-26 11:35:08 +02:00
upscmd - UPS administration program for instant commands
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
SYNOPSIS
--------
2022-07-10 10:23:45 +03:00
2011-01-26 11:35:08 +02:00
*upscmd* -h
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
*upscmd* -l 'ups'
2010-03-26 01:20:59 +02:00
2022-07-10 10:23:45 +03:00
*upscmd* [-u 'username'] [-p 'password'] [-w] [-t <timeout>] 'ups' 'command'
2011-01-26 11:35:08 +02:00
DESCRIPTION
-----------
*upscmd* allows you to invoke "instant commands" in your UPS hardware.
Not all hardware supports this, so check the list with -l to see if anything
will work on your equipment.
2010-03-26 01:20:59 +02:00
On hardware that supports it, you can use this program to start and stop
battery tests, invoke a front panel test (beep!), turn the load on or off,
and more.
2011-01-26 11:35:08 +02:00
OPTIONS
-------
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
*-h*::
2010-03-26 01:20:59 +02:00
Display the help message.
2011-01-26 11:35:08 +02:00
*-l* 'ups'::
2010-03-26 01:20:59 +02:00
Show the list of supported instant commands on that UPS. Some hardware
may not support any of them.
2011-01-26 11:35:08 +02:00
*-u* 'username'::
2010-03-26 01:20:59 +02:00
Set the username for the connection to the server. This is optional, and
2011-01-26 11:35:08 +02:00
you will be prompted for this when invoking a command if -u is not used.
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
*-p* 'password'::
2022-07-10 10:23:45 +03:00
Set the password to authenticate to the server. This is also optional
2011-01-26 11:35:08 +02:00
like -u, and you will be prompted for it if necessary.
2010-03-26 01:20:59 +02:00
2022-07-10 10:23:45 +03:00
*-w*::
Wait for the completion of command execution by the driver and return its
actual result from the device. Note that this feature requires that both upsd
and the driver support TRACKING (NUT version 2.8.0 or higher) or it will
otherwise fail.
The command will also block until an actual result is provided from the driver,
or the timeout is reached (see *-t*).
*-t* 'seconds'::
Set a timeout when using *-w*. Defaults to 10 seconds.
2011-01-26 11:35:08 +02:00
'ups'::
Connect to this UPS. The format is `upsname[@hostname[:port]]`. The default
2010-03-26 01:20:59 +02:00
hostname is "localhost".
2011-01-26 11:35:08 +02:00
UNATTENDED MODE
---------------
2010-03-26 01:20:59 +02:00
If you run this program inside a shell script or similar to invoke
a command, you will need to specify all of the information on the command
2011-01-26 11:35:08 +02:00
line. This means using -u and -p. Otherwise it will put up a prompt and
2010-03-26 01:20:59 +02:00
your program will hang.
This is not necessary when displaying the list, as the username and
2011-01-26 11:35:08 +02:00
password are not required for read-only mode.
2010-03-26 01:20:59 +02:00
2013-11-24 17:00:12 +02:00
Moreover, if you run this program inside a shell script or similar, you
should only consider using output from stdout, not stderr.
2011-01-26 11:35:08 +02:00
DANGEROUS COMMANDS
------------------
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
Some drivers like linkman:apcsmart[8] have built-in paranoia for the
dangerous commands like `load.off`. To make them actually turn off the
2010-03-26 01:20:59 +02:00
load, you will have to send the command twice within a short window.
That is, you will have to send it once, then send it again after 3
seconds elapse but before 15 seconds pass.
This paranoia is entirely defined within the driver. upsd and upscmd have
no control over the timing.
2011-01-26 11:35:08 +02:00
DIAGNOSTICS
-----------
2010-03-26 01:20:59 +02:00
upscmd won't work unless you provide a valid username and password. If
2011-01-26 11:35:08 +02:00
you get "access denied" errors, make sure that your linkman:upsd.users[5] has
2010-03-26 01:20:59 +02:00
an entry for you, and that the username you are using has permissions to
SET variables.
2011-01-26 11:35:08 +02:00
BUGS
----
2010-03-26 01:20:59 +02:00
There is currently no way to tell the user when the driver requires
2022-07-10 10:23:45 +03:00
confirmation to invoke a command such as `load.off`.
2010-03-26 01:20:59 +02:00
This is on the list of things to fix in the future, so don't despair.
It involves magic cookies.
2011-01-26 11:35:08 +02:00
SEE ALSO
--------
2022-07-10 10:23:45 +03:00
2011-01-26 11:35:08 +02:00
linkman:upsd[8], linkman:upsrw[8]
2010-03-26 01:20:59 +02:00
2022-07-10 10:23:45 +03:00
Internet resources:
~~~~~~~~~~~~~~~~~~~
2010-03-26 01:20:59 +02:00
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/