nut-debian/drivers/megatec.c

1037 lines
28 KiB
C
Raw Normal View History

2010-03-26 01:20:59 +02:00
/* -*- mode: c; c-basic-offset: 8; indent-tabs-mode: t; -*-
*
* megatec.c: support for Megatec protocol based UPSes
*
* Copyright (C) Carlos Rodrigues <carlos.efr at mail.telepac.pt>
*
* megatec.c created on 4/10/2003
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; either version 2 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
*/
/*
* A document describing the protocol implemented by this driver can be
* found online at "http://www.networkupstools.org/protocols/megatec.html".
*/
#include "main.h"
#include "serial.h"
#include "megatec.h"
#include <stdio.h>
#include <limits.h>
#include <string.h>
#include <stdlib.h>
#define DRIVER_NAME "Megatec protocol driver"
#define DRIVER_VERSION "1.6" /* FIXME: doesn't conform to "X.YZ" */
/* driver description structure */
upsdrv_info_t upsdrv_info = {
DRIVER_NAME,
DRIVER_VERSION,
"Carlos Rodrigues <carlos.efr@mail.telepac.pt>",
DRV_STABLE,
#ifdef MEGATEC_SUBDRV
{ &megatec_subdrv_info, NULL }
#else
{ NULL }
#endif
};
#define ENDCHAR '\r'
#define IGNCHARS ""
#define RECV_BUFFER_LEN 128
#define FIELD_BUFFER_LEN 16
/* The expected reply lengths */
#define F_CMD_REPLY_LEN 21
#define Q1_CMD_REPLY_LEN 46
#define I_CMD_REPLY_LEN 38
#define IDENT_MAXTRIES 3
#define READ_TIMEOUT 2 /* timeout on read (seconds) */
#define READ_PACE 300000 /* interval to wait between sending a command and reading the response (usec) */
#define MAX_START_DELAY 9999
#define MAX_SHUTDOWN_DELAY 99
/* Maximum length of a string representing these values */
#define MAX_START_DELAY_LEN 4
#define MAX_SHUTDOWN_DELAY_LEN 2
#define MAX_POLL_FAILURES 3
#define N_FLAGS 8
/* The UPS status flags */
#define FL_ON_BATT 0
#define FL_LOW_BATT 1
#define FL_BOOST_TRIM 2
#define FL_FAILED 3
#define FL_UPS_TYPE 4
#define FL_BATT_TEST 5
#define FL_LOAD_OFF 6
#define FL_BEEPER_ON 7 /* bogus on some models */
/* Maximum lengths for the "I" command reply fields */
#define UPS_MFR_CHARS 15
#define UPS_MODEL_CHARS 10
#define UPS_VERSION_CHARS 10
/* Below this value we can safely consider a voltage to be zero */
#define RESIDUAL_VOLTAGE 10.0
/* The values returned by the UPS for an "I" query */
typedef struct {
char mfr[UPS_MFR_CHARS + 1];
char model[UPS_MODEL_CHARS + 1];
char version[UPS_VERSION_CHARS + 1];
} UPSInfo_t;
/* The values returned by the UPS for an "F" query */
typedef struct {
float volt;
float current;
float battvolt;
float freq;
} FirmwareValues_t;
/* The values returned by the UPS for an "Q1" query */
typedef struct {
float ivolt;
float fvolt;
float ovolt;
float load;
float freq;
float battvolt;
float temp;
char flags[N_FLAGS + 1];
} QueryValues_t;
/* Parameters for known battery types */
typedef struct {
float nominal; /* battery voltage (nominal) */
float min; /* lower bound for a single battery of "nominal" voltage (see "set_battery_params" below) */
float max; /* upper bound for a single battery of "nominal" voltage (see "set_battery_params" below) */
float empty; /* fully discharged battery */
float full; /* fully charged battery */
float low; /* low battery (unused) */
} BatteryVolts_t;
/* Known battery types must be in ascending order by "nominal" first, and then by "max". */
static BatteryVolts_t batteries[] = {{ 12.0, 9.0, 16.0, 9.7, 13.7, 0.0 }, /* Mustek PowerMust 600VA Plus (LB unknown) */
{ 12.0, 18.0, 30.0, 18.8, 26.8, 22.3 }, /* PowerWalker Line-Interactive VI 1000 */
{ 23.5, 18.0, 30.0, 21.3, 27.1, 22.2 }, /* UNITEK ALPHA2600 */
{ 24.0, 18.0, 30.0, 19.4, 27.4, 22.2 }, /* Mustek PowerMust 1000VA Plus */
{ 36.0, 1.5, 3.0, 1.64, 2.31, 1.88 }, /* Mustek PowerMust 1000VA On-Line */
{ 36.0, 30.0, 42.0, 32.5, 41.0, 0.0 }, /* Mecer ME-2000 (LB unknown) */
{ 48.0, 38.0, 58.0, 40.0, 54.6, 44.0 }, /* Sven Smart RM2000 */
{ 72.0, 1.5, 3.0, 1.74, 2.37, 1.82 }, /* Effekta RM2000MH */
{ 96.0, 1.5, 3.0, 1.63, 2.29, 1.8 }, /* Ablerex MS3000RT (LB at 25% charge) */
{ 0.0, 0.0, 0.0, 0.0, 0.0, 0.0 }}; /* END OF DATA */
/* Interval between chars on send (usec) */
static int send_pace = 100000;
/* Some models need this */
static char state_dtr = 1;
static char state_rts = 0;
/* Workaround for buggy models */
static char ignore_off = 0; /* ignore FL_LOAD_OFF if it behaves strangely */
/* Defined in upsdrv_initinfo */
static float battvolt_empty = -1; /* unknown */
static float battvolt_full = -1; /* unknown */
/* Battery voltage multiplier (to match the nominal voltage on some models) */
static float battvolt_mult = 1;
/* Minimum and maximum voltage seen on input */
static float ivolt_min = INT_MAX; /* unknown */
static float ivolt_max = -1; /* unknown */
/* In minutes: */
static short start_delay = 2; /* wait at least this amount of time before coming back online */
static short shutdown_delay = 0; /* wait until going offline */
/* In percentage: */
static float lowbatt = -1; /* disabled */
static char watchdog_enabled = 0; /* disabled by default, of course */
static char watchdog_timeout = 1; /* in minutes */
static char *copy_field(char* dest, char *src, int field_len);
static float get_battery_charge(float battvolt);
static int set_battery_params(float volt_nominal, float volt_now);
static int check_ups(QueryValues_t *status);
static int get_ups_info(UPSInfo_t *info);
static int get_firmware_values(FirmwareValues_t *values);
static int run_query(QueryValues_t *values);
int instcmd(const char *cmdname, const char *extra);
int setvar(const char *varname, const char *val);
/* I know, macros should evaluate their arguments only once */
#define CLAMP(x, min, max) (((x) < (min)) ? (min) : (((x) > (max)) ? (max) : (x)))
static char *copy_field(char* dest, char *src, int field_len)
{
int i, j;
/* First we skip the leading spaces... */
for (i = 0; i < field_len; i++) {
if (src[i] != ' ') {
break;
}
}
/* ... then we copy the rest of the field... */
j = 0;
while (i < field_len) {
dest[j] = src[i];
i++; j++;
}
dest[j] = '\0';
/* ...and finally, remove the trailing spaces. */
rtrim(dest, ' ');
return &src[field_len]; /* return the rest of the source buffer */
}
static float get_battery_charge(float battvolt)
{
float value;
if (battvolt_empty < 0 || battvolt_full < 0) {
return -1;
}
battvolt = CLAMP(battvolt, battvolt_empty, battvolt_full);
value = (battvolt - battvolt_empty) / (battvolt_full - battvolt_empty);
return value * 100; /* percentage */
}
/*
* Set the proper limits, depending on the battery voltage,
* so that the "charge" calculations return meaningful values.
*
* This has to be done by looking at the present battery voltage and
* the nominal voltage because, for example, some 24V models will
* show a nominal voltage of 24, while others will show a nominal
* voltage of 12. The present voltage helps telling them apart.
*/
static int set_battery_params(float volt_nominal, float volt_now)
{
int i = 0;
while (batteries[i].nominal > 0) {
if (volt_nominal == batteries[i].nominal) { /* battery voltage matches... */
while (volt_nominal == batteries[i].nominal) { /* ...find the most adequate parameters */
if (volt_now > batteries[i].min && volt_now < batteries[i].max) {
battvolt_empty = batteries[i].empty;
battvolt_full = batteries[i].full;
upsdebugx(1, "%.1fV battery, interval [%.1fV, %.1fV].", volt_nominal, battvolt_empty, battvolt_full);
return i;
}
i++;
}
upsdebugx(1, "%.1fV battery, present voltage (%.1fV) outside of supported intervals.", volt_nominal, volt_now);
return -1;
}
i++;
}
upsdebugx(1, "Unsupported battery voltage (%.1fV).", volt_nominal);
return -1;
}
/*
* The "status" parameter is left unchanged on failure.
*/
static int check_ups(QueryValues_t *status)
{
QueryValues_t values;
if (run_query(&values) < 0) {
return -1;
}
memcpy(status, &values, sizeof(values));
return 0;
}
static int get_ups_info(UPSInfo_t *info)
{
char buffer[RECV_BUFFER_LEN];
char *anchor;
int ret;
upsdebugx(2, "Asking for UPS information [I]...");
ser_flush_io(upsfd);
ser_send_pace(upsfd, send_pace, "I%c", ENDCHAR);
usleep(READ_PACE);
/*
* Expected reply: "#UPS_MFR........ UPS_MODEL. UPS_VER...<cr>"
*/
ret = ser_get_line(upsfd, buffer, RECV_BUFFER_LEN, ENDCHAR, IGNCHARS, READ_TIMEOUT, 0);
if (ret < 0) {
upsdebug_with_errno(2, "I => FAILED");
return -1;
}
if (ret == 0) {
upsdebugx(2, "I => FAILED [timeout]");
return -1;
}
if (ret < I_CMD_REPLY_LEN) {
upsdebugx(2, "I => FAILED [short read]");
upsdebug_hex(3, "I detail", (unsigned char *)buffer, ret);
return -1;
}
if (buffer[0] != '#') {
upsdebugx(2, "I => FAILED [invalid start character]");
upsdebug_hex(3, "I detail", (unsigned char *)buffer, ret);
return -1;
}
upsdebugx(2, "I => OK [%s]", buffer);
memset(info, 0, sizeof(UPSInfo_t));
/*
* Get the manufacturer, model and version fields, skipping
* the separator character that sits between them, as well as
* the first character (the control character, always a '#').
*/
anchor = copy_field(info->mfr, &buffer[1], UPS_MFR_CHARS);
anchor = copy_field(info->model, anchor + 1, UPS_MODEL_CHARS);
copy_field(info->version, anchor + 1, UPS_VERSION_CHARS);
upsdebugx(2, "I VALUES => [%s %s %s]", info->mfr, info->model, info->version);
return 0;
}
static int get_firmware_values(FirmwareValues_t *values)
{
char buffer[RECV_BUFFER_LEN];
char field[FIELD_BUFFER_LEN];
char *anchor;
int ret;
upsdebugx(2, "Asking for UPS power ratings [F]...");
ser_flush_io(upsfd);
ser_send_pace(upsfd, send_pace, "F%c", ENDCHAR);
usleep(READ_PACE);
/*
* Expected reply: "#MMM.M QQQ SS.SS RR.R<cr>"
*/
ret = ser_get_line(upsfd, buffer, RECV_BUFFER_LEN, ENDCHAR, IGNCHARS, READ_TIMEOUT, 0);
if (ret < 0) {
upsdebug_with_errno(2, "F => FAILED");
return -1;
}
if (ret == 0) {
upsdebugx(2, "F => FAILED [timeout]");
return -1;
}
if (ret < F_CMD_REPLY_LEN) {
upsdebugx(2, "F => FAILED [short read]");
upsdebug_hex(3, "F detail", (unsigned char *)buffer, ret);
return -1;
}
if (buffer[0] != '#') {
upsdebugx(2, "F => FAILED [invalid start character]");
upsdebug_hex(3, "F detail", (unsigned char *)buffer, ret);
return -1;
}
upsdebugx(2, "F => OK [%s]", buffer);
anchor = copy_field(field, &buffer[1], 5);
values->volt = atof(field);
anchor = copy_field(field, anchor + 1, 3);
values->current = atof(field);
anchor = copy_field(field, anchor + 1, 5);
values->battvolt = atof(field);
anchor = copy_field(field, anchor + 1, 4);
values->freq = atof(field);
upsdebugx(2, "F VALUES => [%.1f %.1f %.1f %.1f]", values->volt,
values->current, values->battvolt, values->freq);
return 0;
}
static int run_query(QueryValues_t *values)
{
char buffer[RECV_BUFFER_LEN];
char field[FIELD_BUFFER_LEN];
char *anchor;
int ret;
upsdebugx(2, "Asking for UPS status [Q1]...");
ser_flush_io(upsfd);
ser_send_pace(upsfd, send_pace, "Q1%c", ENDCHAR);
usleep(READ_PACE);
/*
* Expected reply: "(MMM.M NNN.N PPP.P QQQ RR.R S.SS TT.T b7b6b5b4b3b2b1b0<cr>"
*/
ret = ser_get_line(upsfd, buffer, RECV_BUFFER_LEN, ENDCHAR, IGNCHARS, READ_TIMEOUT, 0);
if (ret < 0) {
upsdebug_with_errno(2, "Q1 => FAILED");
return -1;
}
if (ret == 0) {
upsdebugx(2, "Q1 => FAILED [timeout]");
return -1;
}
if (ret < Q1_CMD_REPLY_LEN) {
upsdebugx(2, "Q1 => FAILED [short read]");
upsdebug_hex(3, "Q1 detail", (unsigned char *)buffer, ret);
return -1;
}
if (buffer[0] != '(') {
upsdebugx(2, "Q1 => FAILED [invalid start character]");
upsdebug_hex(3, "Q1 detail", (unsigned char *)buffer, ret);
return -1;
}
upsdebugx(2, "Q1 => OK [%s]", buffer);
anchor = copy_field(field, &buffer[1], 5);
values->ivolt = atof(field);
anchor = copy_field(field, anchor + 1, 5);
values->fvolt = atof(field);
anchor = copy_field(field, anchor + 1, 5);
values->ovolt = atof(field);
anchor = copy_field(field, anchor + 1, 3);
values->load = atof(field);
anchor = copy_field(field, anchor + 1, 4);
values->freq = atof(field);
anchor = copy_field(field, anchor + 1, 4);
values->battvolt = atof(field);
anchor = copy_field(field, anchor + 1, 4);
values->temp = atof(field);
anchor = copy_field(values->flags, anchor + 1, N_FLAGS);
if (strlen(values->flags) < N_FLAGS) {
upsdebugx(2, "Q1 => FAILED [flags error]");
return -1;
}
upsdebugx(2, "Q1 VALUES => [%.1f %.1f %.1f %.1f %.1f %.1f %.1f %s]",
values->ivolt, values->fvolt, values->ovolt, values->load,
values->freq, values->battvolt, values->temp, values->flags);
return 0;
}
void upsdrv_initinfo(void)
{
int i;
FirmwareValues_t values;
QueryValues_t status;
UPSInfo_t info;
/*
* Some models apparently time-out with the default send pace, so we must
* allow the user to override it if needed be. The configuration parameter
* is specified in milliseconds for the user's benefit.
*/
if (getval("sendpace")) {
upsdebugx(2, "Default command send pace is %d usec.", send_pace);
upsdebugx(2, "Parameter [sendpace]: [%s]", getval("sendpace"));
/* Having 1 second as the upper-bound is an arbitrary choice... */
send_pace = CLAMP(atoi(getval("sendpace")), 1, 1000) * 1000;
upslogx(LOG_NOTICE, "Command send pace changed to %d usec.", send_pace);
}
/*
* UPS detection sequence.
*/
upsdebugx(1, "Starting UPS detection process...");
/* Some models seem to need this. We'll just discard the ouput for now... */
get_ups_info(&info);
/* Check for a compatible UPS... */
for (i = 0; i < IDENT_MAXTRIES; i++) {
if (check_ups(&status) == 0) {
break;
}
}
if (i == IDENT_MAXTRIES) {
fatalx(EXIT_FAILURE, "Megatec protocol UPS not detected.");
}
dstate_setinfo("ups.type", status.flags[FL_UPS_TYPE] == '1' ? "standby" : "online");
upsdebugx(1, "Cancelling any pending shutdown or battery test.");
ser_send_pace(upsfd, send_pace, "C%c", ENDCHAR);
/*
* Try to identify the UPS.
*/
if (get_ups_info(&info) >= 0) {
char model[UPS_MODEL_CHARS + UPS_VERSION_CHARS + 2];
snprintf(model, sizeof(model), "%s %s", info.model, info.version);
dstate_setinfo("ups.mfr", "%s", getval("mfr") ? getval("mfr") : info.mfr);
dstate_setinfo("ups.model", "%s", getval("model") ? getval("model") : model);
upslogx(LOG_INFO, "Megatec protocol UPS detected [%s %s %s].", info.mfr, info.model, info.version);
} else {
dstate_setinfo("ups.mfr", "%s", getval("mfr") ? getval("mfr") : "unknown");
dstate_setinfo("ups.model", "%s", getval("model") ? getval("model") : "unknown");
upslogx(LOG_INFO, "Megatec protocol UPS detected.");
}
dstate_setinfo("ups.serial", "%s", getval("serial") ? getval("serial") : "unknown");
/*
* Workaround for buggy models.
*/
ignore_off = testvar("ignoreoff");
if (status.flags[FL_LOAD_OFF] == '1' && status.load > 0.01 && !ignore_off) {
ignore_off = 1;
upslogx(LOG_INFO, "The UPS reports OFF status but appears to be ON. Parameter \"ignoreoff\" set automatically.");
}
upsdebugx(2, "Parameter [ignoreoff]: [%s]", (ignore_off ? "true" : "false"));
/*
* Set battery-related values.
*/
if (get_firmware_values(&values) >= 0) {
dstate_setinfo("battery.voltage.nominal", "%.1f", values.battvolt);
dstate_setinfo("input.voltage.nominal", "%.1f", values.volt);
dstate_setinfo("input.frequency.nominal", "%.1f", values.freq);
if (set_battery_params(values.battvolt, status.battvolt) < 0) {
upslogx(LOG_NOTICE, "This UPS has an unsupported combination of battery voltage/number of batteries.");
}
}
if (getval("battvoltmult")) {
upsdebugx(2, "Parameter [battvoltmult]: [%s]", getval("battvoltmult"));
/* Having SHRT_MAX as the upper-bound is an arbitrary choice... */
battvolt_mult = CLAMP(atof(getval("battvoltmult")), 1, SHRT_MAX);
upslogx(LOG_NOTICE, "The battery voltage reported by the UPS will be multiplied by %.1f.", battvolt_mult);
}
if (getval("battvolts")) {
upsdebugx(2, "Parameter [battvolts]: [%s]", getval("battvolts"));
if (sscanf(getval("battvolts"), "%f:%f", &battvolt_empty, &battvolt_full) != 2) {
fatalx(EXIT_FAILURE, "Error in \"battvolts\" parameter.");
}
upslogx(LOG_NOTICE, "Overriding battery voltage interval [%.1fV, %.1fV].", battvolt_empty, battvolt_full);
}
if (battvolt_empty < 0 || battvolt_full < 0) {
upslogx(LOG_NOTICE, "Cannot calculate charge percentage for this UPS.");
}
if (getval("lowbatt")) {
if (battvolt_empty < 0 || battvolt_full < 0) {
upslogx(LOG_NOTICE, "Ignoring \"lowbatt\" parameter.");
} else {
lowbatt = CLAMP(atof(getval("lowbatt")), 0, 100);
}
}
/*
* Set the restart and shutdown delays.
*/
if (getval("ondelay")) {
start_delay = CLAMP(atoi(getval("ondelay")), 0, MAX_START_DELAY);
}
if (getval("offdelay")) {
shutdown_delay = CLAMP(atoi(getval("offdelay")), 0, MAX_SHUTDOWN_DELAY);
}
dstate_setinfo("ups.delay.start", "%d", start_delay);
dstate_setinfo("ups.delay.shutdown", "%d", shutdown_delay);
/*
* Register the available instant commands.
*/
dstate_addcmd("test.battery.start.deep");
dstate_addcmd("test.battery.start");
dstate_addcmd("test.battery.stop");
dstate_addcmd("shutdown.return");
dstate_addcmd("shutdown.stayoff");
dstate_addcmd("shutdown.stop");
dstate_addcmd("load.on");
dstate_addcmd("load.off");
dstate_addcmd("reset.input.minmax");
dstate_addcmd("reset.watchdog");
dstate_addcmd("beeper.toggle");
upsh.instcmd = instcmd;
upsh.setvar = setvar;
upsdebugx(1, "Done setting up the UPS.");
}
void upsdrv_updateinfo(void)
{
QueryValues_t query;
float charge;
static int poll_fail = 0;
if (run_query(&query) < 0) {
/*
* Query wasn't successful (we got some weird
* response), however we won't fatalx(EXIT_FAILURE, ) as this
* happens sometimes when the ups is offline.
*
* Some fault tolerance is good, we just assume
* that the UPS is just taking a nap. ;)
*/
poll_fail++;
upsdebugx(2, "Poll failure [%d].", poll_fail);
ser_comm_fail("No status from UPS.");
if (poll_fail >= MAX_POLL_FAILURES) {
upsdebugx(2, "Too many poll failures, data is stale.");
dstate_datastale();
}
return;
}
poll_fail = 0;
ser_comm_good();
dstate_setinfo("input.voltage", "%.1f", query.ivolt);
dstate_setinfo("input.voltage.fault", "%.1f", query.fvolt);
dstate_setinfo("output.voltage", "%.1f", query.ovolt);
dstate_setinfo("ups.load", "%.1f", query.load);
dstate_setinfo("input.frequency", "%.1f", query.freq);
/*
* The battery voltage multiplier should only be applied to battery.voltage
* in order not to break the charge calculation (that uses the 'raw' value
* that is reported by the UPS).
*/
dstate_setinfo("battery.voltage", "%.2f", battvolt_mult * query.battvolt);
if (query.temp > 0.01) {
dstate_setinfo("ups.temperature", "%.1f", query.temp);
}
charge = get_battery_charge(query.battvolt);
if (charge >= 0) {
dstate_setinfo("battery.charge", "%.1f", charge);
upsdebugx(2, "Calculated battery charge: %.1f%%", charge);
}
dstate_setinfo("ups.beeper.status", query.flags[FL_BEEPER_ON] == '1' ? "enabled" : "disabled");
status_init();
/*
* Some models, when OFF, never change to on-battery status when
* line power is unavailable. To get around this, we also look at
* the input voltage level here.
*/
if (query.flags[FL_ON_BATT] == '1' || query.ivolt < RESIDUAL_VOLTAGE) {
status_set("OB");
} else {
status_set("OL");
if (query.flags[FL_BOOST_TRIM] == '1') {
if (query.ivolt < query.ovolt) {
status_set("BOOST");
} else if (query.ivolt > query.ovolt) {
status_set("TRIM");
} else {
status_set("BYPASS");
}
}
/* Update minimum and maximum input voltage levels too */
if (query.ivolt < ivolt_min) {
ivolt_min = query.ivolt;
}
if (query.ivolt > ivolt_max) {
ivolt_max = query.ivolt;
}
dstate_setinfo("input.voltage.minimum", "%.1f", ivolt_min);
dstate_setinfo("input.voltage.maximum", "%.1f", ivolt_max);
}
/*
* If "lowbatt > 0", it becomes a "soft" low battery level
* and the hardware flag "FL_LOW_BATT" is always ignored.
*/
if ((lowbatt <= 0 && query.flags[FL_LOW_BATT] == '1') ||
(lowbatt > 0 && charge < lowbatt)) {
status_set("LB");
}
if (query.flags[FL_BATT_TEST] == '1') {
status_set("CAL");
}
if (query.flags[FL_LOAD_OFF] == '1' && !ignore_off) {
status_set("OFF");
}
alarm_init();
if (query.flags[FL_FAILED] == '1') {
alarm_set("Internal UPS fault!");
}
alarm_commit();
status_commit();
dstate_dataok();
}
void upsdrv_shutdown(void)
{
int s_wait = getval("offdelay") ? CLAMP(atoi(getval("offdelay")), 0, MAX_SHUTDOWN_DELAY) : shutdown_delay;
int r_wait = getval("ondelay") ? CLAMP(atoi(getval("ondelay")), 0, MAX_START_DELAY) : start_delay;
upslogx(LOG_INFO, "Shutting down UPS.");
ser_send_pace(upsfd, send_pace, "C%c", ENDCHAR);
ser_send_pace(upsfd, send_pace, "S%02dR%04d%c", s_wait, r_wait, ENDCHAR);
}
int instcmd(const char *cmdname, const char *extra)
{
char buffer[RECV_BUFFER_LEN];
/*
* Some commands are always supported by every UPS implementing
* the megatec protocol, but others may or may not be supported.
* Unsupported commands are echoed back without ENDCHAR.
*/
if (strcasecmp(cmdname, "test.battery.start.deep") == 0) {
ser_flush_io(upsfd);
ser_send_pace(upsfd, send_pace, "TL%c", ENDCHAR);
usleep(READ_PACE);
if (ser_get_line(upsfd, buffer, 2 + 1, '\0', IGNCHARS, READ_TIMEOUT, 0) > 0) {
upslogx(LOG_NOTICE, "test.battery.start.deep not supported by UPS hardware.");
} else {
upslogx(LOG_INFO, "Deep battery test started.");
}
return STAT_INSTCMD_HANDLED;
}
if (strcasecmp(cmdname, "test.battery.start") == 0) {
ser_flush_io(upsfd);
ser_send_pace(upsfd, send_pace, "T%c", ENDCHAR);
usleep(READ_PACE);
if (ser_get_line(upsfd, buffer, 1 + 1, '\0', IGNCHARS, READ_TIMEOUT, 0) > 0) {
upslogx(LOG_NOTICE, "test.battery.start not supported by UPS hardware.");
} else {
upslogx(LOG_INFO, "Battery test started.");
}
return STAT_INSTCMD_HANDLED;
}
if (strcasecmp(cmdname, "test.battery.stop") == 0) {
ser_flush_io(upsfd);
ser_send_pace(upsfd, send_pace, "CT%c", ENDCHAR);
usleep(READ_PACE);
if (ser_get_line(upsfd, buffer, 2 + 1, '\0', IGNCHARS, READ_TIMEOUT, 0) > 0) {
upslogx(LOG_NOTICE, "test.battery.stop not supported by UPS hardware.");
} else {
upslogx(LOG_INFO, "Battery test stopped.");
}
return STAT_INSTCMD_HANDLED;
}
if (strcasecmp(cmdname, "shutdown.return") == 0) {
ser_send_pace(upsfd, send_pace, "C%c", ENDCHAR);
watchdog_enabled = 0;
ser_send_pace(upsfd, send_pace, "S%02dR%04d%c", shutdown_delay, start_delay, ENDCHAR);
upslogx(LOG_INFO, "Shutdown (return) initiated.");
return STAT_INSTCMD_HANDLED;
}
if (strcasecmp(cmdname, "shutdown.stayoff") == 0) {
ser_send_pace(upsfd, send_pace, "C%c", ENDCHAR);
watchdog_enabled = 0;
ser_flush_io(upsfd);
ser_send_pace(upsfd, send_pace, "S%02d%c", shutdown_delay, ENDCHAR);
usleep(READ_PACE);
if (ser_get_line(upsfd, buffer, 3 + 1, '\0', IGNCHARS, READ_TIMEOUT, 0) > 0) {
ser_send_pace(upsfd, send_pace, "S%02dR9999%c", shutdown_delay, ENDCHAR);
upslogx(LOG_NOTICE, "UPS refuses to turn the load off indefinitely. Will turn off for 9999 minutes instead.");
}
upslogx(LOG_INFO, "Shutdown (stayoff) initiated.");
return STAT_INSTCMD_HANDLED;
}
if (strcasecmp(cmdname, "shutdown.stop") == 0) {
ser_send_pace(upsfd, send_pace, "C%c", ENDCHAR);
watchdog_enabled = 0;
upslogx(LOG_INFO, "Shutdown canceled.");
return STAT_INSTCMD_HANDLED;
}
if (strcasecmp(cmdname, "load.on") == 0) {
ser_send_pace(upsfd, send_pace, "C%c", ENDCHAR);
watchdog_enabled = 0;
upslogx(LOG_INFO, "Turning the load on.");
return STAT_INSTCMD_HANDLED;
}
if (strcasecmp(cmdname, "load.off") == 0) {
ser_send_pace(upsfd, send_pace, "C%c", ENDCHAR);
watchdog_enabled = 0;
ser_flush_io(upsfd);
ser_send_pace(upsfd, send_pace, "S00%c", ENDCHAR);
usleep(READ_PACE);
if (ser_get_line(upsfd, buffer, 3 + 1, '\0', IGNCHARS, READ_TIMEOUT, 0) > 0) {
ser_send_pace(upsfd, send_pace, "S00R9999%c", ENDCHAR);
upslogx(LOG_NOTICE, "UPS refuses to turn the load off indefinitely. Will turn off for 9999 minutes instead.");
}
upslogx(LOG_INFO, "Turning the load off.");
return STAT_INSTCMD_HANDLED;
}
if (strcasecmp(cmdname, "reset.input.minmax") == 0) {
ivolt_min = INT_MAX;
ivolt_max = -1;
dstate_setinfo("input.voltage.minimum", "%.1f", ivolt_min);
dstate_setinfo("input.voltage.maximum", "%.1f", ivolt_max);
upslogx(LOG_INFO, "Resetting minimum and maximum input voltage values.");
return STAT_INSTCMD_HANDLED;
}
if (strcasecmp(cmdname, "reset.watchdog") == 0) {
ser_send_pace(upsfd, send_pace, "C%c", ENDCHAR);
ser_send_pace(upsfd, send_pace, "S%02dR0001%c", watchdog_timeout, ENDCHAR);
if (watchdog_enabled) {
upsdebugx(2, "Resetting the UPS watchdog.");
} else {
watchdog_enabled = 1;
upslogx(LOG_INFO, "UPS watchdog started.");
}
return STAT_INSTCMD_HANDLED;
}
if (strcasecmp(cmdname, "beeper.toggle") == 0) {
ser_flush_io(upsfd);
ser_send_pace(upsfd, send_pace, "Q%c", ENDCHAR);
usleep(READ_PACE);
if (ser_get_line(upsfd, buffer, 1 + 1, '\0', IGNCHARS, READ_TIMEOUT, 0) > 0) {
upslogx(LOG_NOTICE, "beeper.toggle not supported by UPS hardware.");
} else {
upslogx(LOG_INFO, "Toggling UPS beeper.");
}
return STAT_INSTCMD_HANDLED;
}
upslogx(LOG_NOTICE, "instcmd: unknown command [%s]", cmdname);
return STAT_INSTCMD_UNKNOWN;
}
int setvar(const char *varname, const char *val)
{
return STAT_SET_UNKNOWN;
}
void upsdrv_help(void)
{
}
void upsdrv_makevartable(void)
{
addvar(VAR_VALUE, "mfr", "Manufacturer name");
addvar(VAR_VALUE, "model", "Model name");
addvar(VAR_VALUE, "serial", "UPS serial number");
addvar(VAR_VALUE, "lowbatt", "Low battery level (%)");
addvar(VAR_VALUE, "ondelay", "Min. delay before UPS startup (minutes)");
addvar(VAR_VALUE, "offdelay", "Delay before UPS shutdown (minutes)");
addvar(VAR_VALUE, "battvolts", "Battery voltages (empty:full)");
addvar(VAR_VALUE, "battvoltmult", "Battery voltage multiplier");
addvar(VAR_FLAG , "ignoreoff", "Ignore the OFF status from the UPS");
addvar(VAR_VALUE, "sendpace", "Interval between command chars (msec)");
addvar(VAR_VALUE, "dtr", "Serial DTR line state (0/1)");
addvar(VAR_VALUE, "rts", "Serial RTS line state (0/1)");
megatec_subdrv_makevartable();
}
void upsdrv_initups(void)
{
upsfd = ser_open(device_path);
ser_set_speed(upsfd, device_path, B2400);
if (getval("dtr")) {
upsdebugx(2, "Parameter [dtr]: [%s]", getval("dtr"));
if (strcmp(getval("dtr"), "0") != 0 && strcmp(getval("dtr"), "1") != 0) {
fatalx(EXIT_FAILURE, "Error in \"dtr\" parameter.");
}
state_dtr = atoi(getval("dtr"));
}
if (getval("rts")) {
upsdebugx(2, "Parameter [rts]: [%s]", getval("rts"));
if (strcmp(getval("rts"), "0") != 0 && strcmp(getval("rts"), "1") != 0) {
fatalx(EXIT_FAILURE, "Error in \"rts\" parameter.");
}
state_rts = atoi(getval("rts"));
}
upsdebugx(2, "DTR=%d, RTS=%d", state_dtr, state_rts);
ser_set_dtr(upsfd, state_dtr);
ser_set_rts(upsfd, state_rts);
}
void upsdrv_cleanup(void)
{
ser_set_dtr(upsfd, 0);
ser_close(upsfd, device_path);
}
/* EOF - megatec.c */