APCSMART(8)
===========
NAME
----
apcsmart - Driver for American Power Conversion Smart Protocol UPS equipment
SYNOPSIS
--------
*apcsmart* -h
*apcsmart* -a 'UPS_NAME' ['OPTIONS']
NOTE: This man page only documents the hardware-specific features of the
2010-03-26 01:20:59 +02:00
apcsmart driver. For information about the core driver, see
2011-01-26 11:35:08 +02:00
linkman:nutupsdrv[8].
SUPPORTED HARDWARE
------------------
2010-03-26 01:20:59 +02:00
apcsmart should recognize all recent APC models that use a serial
2011-01-26 11:35:08 +02:00
protocol at 2400 bps. This is primarily the Smart-UPS, Matrix-UPS and
Back-UPS Pro lines.
2010-03-26 01:20:59 +02:00
The driver attempts to support every bell and whistle of the APC
reporting interface, whether or not this is strictly sensible.
Some older hardware may only report a handful of variables. This is
2011-01-26 11:35:08 +02:00
usually not a bug--they just don't support anything else.
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
CABLING
-------
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
This driver expects to see a 940-0024C cable or a clone by default. You
can switch to the 940-0095B dual-mode cable support with the `cable=`
2010-03-26 01:20:59 +02:00
definition described below.
2011-01-26 11:35:08 +02:00
If your 940-0024C cable is broken or missing, use this diagram to build
2010-03-26 01:20:59 +02:00
a clone:
2011-01-26 11:35:08 +02:00
http://www.networkupstools.org/cables/940-0024C.jpg
EXTRA ARGUMENTS
---------------
2010-03-26 01:20:59 +02:00
This driver supports the following optional settings in the
2011-01-26 11:35:08 +02:00
linkman:ups.conf[5]:
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
*cable=940-0095B*::
Configure the serial port for the APC 940-0095B dual-mode cable.
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
*sdtype=*'num'::
Use shutdown type 'num', according to this table:
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
0;; soft shutdown or powerdown, depending on battery status
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
1;; soft shutdown followed by powerdown
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
2;; instant power off
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
3;; power off with grace period
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
4;; "force OB" hack method for CS 350
2010-03-26 01:20:59 +02:00
Modes 0 and 1 will power up the load when power returns. Modes 2 and 3
will keep the load turned off when the power returns.
Mode 4 exploits an oddity in the CS 350 models since they only seem to
support the S command, but then only when running on battery. As a
result, the driver will force the UPS to go on battery if necessary
before sending the shutdown command. This ensures that the load gets
reset.
2011-01-26 11:35:08 +02:00
BUGS
----
2010-03-26 01:20:59 +02:00
Some older APC UPS models return bogus data in the status register during
a front panel test. This is usually detected and discarded, but some
other unexpected values have occasionally slipped through.
APC UPS models with both USB and serial ports require a power cycle when
switching from USB communication to serial, and perhaps vice versa.
2011-01-26 11:35:08 +02:00
AUTHOR
------
2010-03-26 01:20:59 +02:00
Nigel Metheringham <Nigel.Metheringham@Intechnology.co.uk> (drawing
heavily on the original apcsmart driver by Russell Kroll). This driver
was called newapc for a time and was renamed in the 1.5 series.
2011-01-26 11:35:08 +02:00
SEE ALSO
--------
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
The core driver:
~~~~~~~~~~~~~~~~
linkman:nutupsdrv[8]
2010-03-26 01:20:59 +02:00
2011-01-26 11:35:08 +02:00
Internet resources:
~~~~~~~~~~~~~~~~~~~
2010-03-26 01:20:59 +02:00
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/