/* emerson-avocent-pdu-mib.c - subdriver to monitor Emerson Avocent PDUs with NUT
*
* Copyright (C)
* 2008-2018 Arnaud Quette <arnaud.quette@gmail.com>
* 2009 Opengear <support@opengear.com>
* 2017-2019 Eaton (Arnaud Quette <ArnaudQuette@Eaton.com>)
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation; either version 2 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, write to the Free Software
* Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
*
*/
#define OPENGEAR_MULTIPLE_BANKS 1
#include "emerson-avocent-pdu-mib.h"
#define EMERSON_AVOCENT_MIB_VERSION "1.3"
#define EMERSON_AVOCENT_SYSOID ".1.3.6.1.4.1.10418.17.1.7"
#define EMERSON_AVOCENT_OID_MODEL_NAME ".1.3.6.1.4.1.10418.17.2.1.2.0"
/* FIXME: Avocent PM's seem to have 3 temperature sensors (index 1, 2, 3)
* for the embedded temperature (equivalent to ups.temperature) */
#define AVOCENT_OID_UNIT_TEMPERATURE ".1.3.6.1.4.1.10418.17.2.5.3.1.17.1.1"
/* Same as above for humidity... */
#define AVOCENT_OID_UNIT_HUMIDITY ".1.3.6.1.4.1.10418.17.2.5.3.1.24.1"
#define AVOCENT_OID_OUTLET_COUNT ".1.3.6.1.4.1.10418.17.2.5.3.1.8.%i.%i"
/* FIXME: This is actually pmPowerMgmtPDUTableCurrent1Value */
#define AVOCENT_OID_UNIT_CURRENT ".1.3.6.1.4.1.10418.17.2.5.3.1.10.1.1"
/* FIXME: This is actually pmPowerMgmtPDUTableVoltage1Value */
#define AVOCENT_OID_UNIT_VOLTAGE ".1.3.6.1.4.1.10418.17.2.5.3.1.31.1.1"
#define AVOCENT_OID_UNIT_MACADDR ".1.3.6.1.2.1.2.2.1.6.1"
#ifdef OPENGEAR_MULTIPLE_BANKS
#define AVOCENT_OID_OUTLET_ID ".1.3.6.1.4.1.10418.17.2.5.5.1.3"
#define AVOCENT_OID_OUTLET_NAME ".1.3.6.1.4.1.10418.17.2.5.5.1.4"
#define AVOCENT_OID_OUTLET_STATUS ".1.3.6.1.4.1.10418.17.2.5.5.1.5"
/* This the actual value for the Current of the sensor. */
#define AVOCENT_OID_OUTLET_LOAD ".1.3.6.1.4.1.10418.17.2.5.5.1.50"
#define AVOCENT_OID_OUTLET_CONTROL ".1.3.6.1.4.1.10418.17.2.5.5.1.6"
#else
#define AVOCENT_OID_OUTLET_ID ".1.3.6.1.4.1.10418.17.2.5.5.1.3.1.1"
#define AVOCENT_OID_OUTLET_NAME ".1.3.6.1.4.1.10418.17.2.5.5.1.4.1.1"
#define AVOCENT_OID_OUTLET_STATUS ".1.3.6.1.4.1.10418.17.2.5.5.1.5.1.1"
#define AVOCENT_OID_OUTLET_LOAD ".1.3.6.1.4.1.10418.17.2.5.5.1.50.1.1"
#define AVOCENT_OID_OUTLET_CONTROL ".1.3.6.1.4.1.10418.17.2.5.5.1.6.1.1"
#endif
static info_lkp_t avocent_outlet_status_info[] = {
{ 1, "off", NULL, NULL },
{ 2, "on", NULL, NULL },
/* { 3, "offLocked", NULL, NULL },
{ 4, "onLocked", NULL, NULL },
{ 5, "offCycle", NULL, NULL },
{ 6, "onPendingOff", NULL, NULL },
{ 7, "offPendingOn", NULL, NULL },
{ 8, "onPendingCycle", NULL, NULL },
{ 9, "notSet", NULL, NULL },
{ 10, "onFixed", NULL, NULL },
{ 11, "offShutdown", NULL, NULL },
{ 12, "tripped", NULL, NULL },*/
{ 0, NULL, NULL, NULL }
};
static snmp_info_t emerson_avocent_pdu_mib[] = {
/* standard MIB items */
{ "device.description", ST_FLAG_STRING | ST_FLAG_RW, SU_INFOSIZE, ".1.3.6.1.2.1.1.1.0", NULL, SU_FLAG_OK, NULL },
{ "device.contact", ST_FLAG_STRING | ST_FLAG_RW, SU_INFOSIZE, ".1.3.6.1.2.1.1.4.0", NULL, SU_FLAG_OK, NULL },
{ "device.location", ST_FLAG_STRING | ST_FLAG_RW, SU_INFOSIZE, ".1.3.6.1.2.1.1.6.0", NULL, SU_FLAG_OK, NULL },
/* Device page */
{ "device.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "Avocent",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "device.model", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.10418.17.2.5.3.1.5.1.%i", /* EMERSON_AVOCENT_OID_MODEL_NAME */
"Avocent SNMP PDU", SU_FLAG_ABSENT | SU_FLAG_OK | SU_FLAG_NAINVALID, NULL },
{ "device.serial", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.10418.17.2.1.4.0", "",
SU_FLAG_STATIC | SU_FLAG_OK, NULL },
{ "device.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "pdu",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
/* Daisychained devices support
* Notes: this definition is used to:
* - estimate the number of devices, based on the below OID iteration capabilities
* - determine the base index of the SNMP OID (ie 0 or 1) */
{ "device.count", 0, 1, ".1.3.6.1.4.1.10418.17.2.5.2.1.4.1",
"1", SU_FLAG_STATIC, NULL },
/* UPS page */
{ "ups.mfr", ST_FLAG_STRING, SU_INFOSIZE, NULL, "Avocent",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "ups.model", ST_FLAG_STRING, SU_INFOSIZE, EMERSON_AVOCENT_OID_MODEL_NAME,
"Avocent SNMP PDU", SU_FLAG_STATIC | SU_FLAG_OK, NULL },
{ "ups.id", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.10418.17.2.1.1.0",
"unknown", SU_FLAG_STATIC | SU_FLAG_OK, NULL },
{ "ups.serial", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.10418.17.2.1.4.0", "",
SU_FLAG_STATIC | SU_FLAG_OK, NULL },
{ "ups.firmware", ST_FLAG_STRING, SU_INFOSIZE, ".1.3.6.1.4.1.10418.17.2.1.7.0", "",
SU_FLAG_STATIC | SU_FLAG_OK, NULL },
{ "ups.type", ST_FLAG_STRING, SU_INFOSIZE, NULL, "pdu",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "ups.macaddr", ST_FLAG_STRING, SU_INFOSIZE, AVOCENT_OID_UNIT_MACADDR,
"", SU_FLAG_STATIC | SU_FLAG_OK, NULL },
/* Outlet page */
{ "outlet.id", 0, 1, NULL, "0", SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "outlet.desc", ST_FLAG_RW | ST_FLAG_STRING, 20, NULL, "All outlets",
SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK, NULL },
{ "outlet.count", 0, 1, ".1.3.6.1.4.1.10418.17.2.5.3.1.8.1.%i", "0", SU_FLAG_STATIC | SU_FLAG_ZEROINVALID | SU_FLAG_OK, NULL },
/* outlets */
/* NOTE: there is a bug in Avocent FW:
* index '0' should not respond (and is not in subtree mode) but answers
* to unitary get, since OIDs start at index '1'.
*Use the status data below to test since '0' is not a supported value */
{ "outlet.%i.status", ST_FLAG_STRING, SU_INFOSIZE,
".1.3.6.1.4.1.10418.17.2.5.5.1.5.1.%i.%i", NULL, SU_OUTLET | SU_TYPE_DAISY_1 | SU_FLAG_ZEROINVALID, &avocent_outlet_status_info[0] },
{ "outlet.%i.id", 0, 1,
".1.3.6.1.4.1.10418.17.2.5.5.1.3.1.%i.%i", NULL, SU_FLAG_STATIC | SU_FLAG_ABSENT | SU_FLAG_OK | SU_OUTLET | SU_TYPE_DAISY_1, NULL },
{ "outlet.%i.desc", ST_FLAG_RW | ST_FLAG_STRING, SU_INFOSIZE,
".1.3.6.1.4.1.10418.17.2.5.5.1.4.1.%i.%i", NULL, SU_OUTLET | SU_TYPE_DAISY_1 | SU_FLAG_NAINVALID, NULL },
/* pmPowerMgmtOutletsTableCurrentValue.1.1.1; Value (Integer): 0 */
{ "outlet.%i.current", 0, 0.1,
".1.3.6.1.4.1.10418.17.2.5.5.1.50.1.%i.%i", NULL, SU_OUTLET | SU_TYPE_DAISY_1, NULL },
/* pmPowerMgmtOutletsTableCurrentHighCritical.1.1.1; Value (Integer): 160 */
{ "outlet.%i.current.high.critical", ST_FLAG_RW, 0.1,
".1.3.6.1.4.1.10418.17.2.5.5.1.100.1.%i.%i",
NULL, SU_OUTLET | SU_TYPE_DAISY_1, NULL },
/* pmPowerMgmtOutletsTableCurrentHighWarning.1.1.1; Value (Integer): 120 */
{ "outlet.%i.current.high.warning", ST_FLAG_RW, 0.1,
".1.3.6.1.4.1.10418.17.2.5.5.1.101.1.%i.%i",
NULL, SU_OUTLET | SU_TYPE_DAISY_1, NULL },
/* pmPowerMgmtOutletsTableCurrentLowWarning.1.1.1; Value (Integer): 0 */
{ "outlet.%i.current.low.warning", ST_FLAG_RW, 0.1,
".1.3.6.1.4.1.10418.17.2.5.5.1.102.1.%i.%i",
NULL, SU_OUTLET | SU_TYPE_DAISY_1, NULL },
/* pmPowerMgmtOutletsTableCurrentLowCritical.1.1.1; Value (Integer): 0 */
{ "outlet.%i.current.low.critical", ST_FLAG_RW, 0.1,
".1.3.6.1.4.1.10418.17.2.5.5.1.103.1.%i.%i",
NULL, SU_OUTLET | SU_TYPE_DAISY_1, NULL },
/* pmPowerMgmtOutletsTablePowerValue.1.1.1; Value (Integer): 0 */
{ "outlet.%i.realpower", 0, 0.1,
".1.3.6.1.4.1.10418.17.2.5.5.1.60.1.%i.%i", NULL, SU_OUTLET | SU_TYPE_DAISY_1, NULL },
/* pmPowerMgmtOutletsTableVoltageValue.1.1.1; Value (Integer): 238 */
{ "outlet.%i.voltage", 0, 1,
".1.3.6.1.4.1.10418.17.2.5.5.1.70.1.%i.%i", NULL, SU_OUTLET | SU_TYPE_DAISY_1, NULL },
/* TODO: handle statistics
* pmPowerMgmtOutletsTableEnergyValue.1.1.1; Value (Integer): 0 (Wh)
* pmPowerMgmtOutletsTableEnergyStartTime.1.1.1; Value (OctetString): 2018-02-13 10:40:09
* pmPowerMgmtOutletsTableEnergyReset.1.1.1; Value (Integer): noAction (1)
*/
/* Outlet groups collection */
/* pmPowerMgmtNumberOfOutletGroup.0; Value (Integer): 0 */
{ "outlet.group.count", 0, 1, ".1.3.6.1.4.1.10418.17.2.5.6.%i",
"0", SU_FLAG_STATIC | SU_TYPE_DAISY_1, NULL },
/* TODO: support for "Banks" (not sure to understand what is this?!)
* pmPowerMgmtTotalNumberOfBanks.0; Value (Integer): 6
* pmPowerMgmtBanksTableName.1.1.1; Value (OctetString): 18-bf-ffP0_1_A
*/
/* According to MIB Power Control values are:
* noAction(1),
* powerOn(2),
* powerOff(3),
* powerCycle(4),
* powerLock(5),
* powerUnlock(6)
*/
{ "outlet.%i.load.cycle", 0, 1, ".1.3.6.1.4.1.10418.17.2.5.5.1.6.1.%i.%i", "4", SU_TYPE_CMD | SU_OUTLET | SU_TYPE_DAISY_1, NULL },
{ "outlet.%i.load.off", 0, 1, ".1.3.6.1.4.1.10418.17.2.5.5.1.6.1.%i.%i", "3", SU_TYPE_CMD | SU_OUTLET | SU_TYPE_DAISY_1, NULL },
{ "outlet.%i.load.on", 0, 1, ".1.3.6.1.4.1.10418.17.2.5.5.1.6.1.%i.%i", "2", SU_TYPE_CMD | SU_OUTLET | SU_TYPE_DAISY_1, NULL },
/* end of structure. */
{ NULL, 0, 0, NULL, NULL, 0, NULL }
};
mib2nut_info_t emerson_avocent_pdu = { "emerson_avocent_pdu", EMERSON_AVOCENT_MIB_VERSION, NULL, EMERSON_AVOCENT_OID_MODEL_NAME, emerson_avocent_pdu_mib, EMERSON_AVOCENT_SYSOID, NULL };